Preferred Language
Articles
/
ijl-236
TREATMENT OF SYMPTOMATIC CERVICAL ECTOPY USING CO2 LASER (10600 nm) – Case Study
...Show More Authors

Background: Cervical ectopy advanced to erosion is one of the common conditions in gynecological and pathological study. It is considered as a physiologic condition resulting from columnar epithelium migration from the cervical canal into the vaginal portion of the cervix, in which no treatment for asymptomatic cervical ectropion can be given. Treatment can be accomplished via thermal cauterization (Electro cautery), Cryosurgery. CO2 laser therapy is another modality of treatment.

Objective: To study the effectiveness of CO2 laser therapy and evaluate it as a biomedical tool for the treatment of cervical ectropion. The study was done at Laser Medicine Research Clinic at the Institute of Laser for Postgraduate Studies, University of Baghdad during a period of three months from (1st August  to 30th October) 2018.

Methods: Ten female Patients with age range between 22 to 40 years old who attended the private clinic or the outpatient clinic of Al-Imamain Al-Kadhmain Medical City and diagnosed with cervical ectropion. Patients were diagnosed clinically as having cervical ectropion. Pap smear was done   to   all   patients at the Department of Health (Pap smear unit) at Al-Imamain Al-Kadhmain Medical City in order to exclude an underlying dysplasia. The patients were subjected to CO2 laser therapy at a continuous mode. All patients were subjected to continuous wave laser and the range of power from 5 up to 10 Watt. The exposure time ranged from 1-2 minutes.

Results: From all studied patients only three had mild bleeding during procedure and there was no pain reported during procedure except mild pain in two patients. So, simple analgesia (mefenamic acid 500 mg.) was given to them. No need for a prophylactic antibiotic in all patients.  After two weeks follow up, the findings were slight vaginal discharge, no slough. Complete healing of erosion was noticed by the 4th week after procedure.

Conclusion: Laser therapy with CO2 10600nm at specific parameters was effective in treating women with cervical ectropion, which was non-invasive and acceptable by the women as a method of treatment, by laser we can treat precisely the affected area without affecting the surrounding healthy tissue.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Apr 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Re-distribution of income in favor of the poor - theoretical entrance of stagnation treatment
...Show More Authors

Research deals the crises of the global recession of the facets of different and calls for the need to think out of the ordinary theory and find the arguments of the theory to accommodate the evolution of life, globalization and technological change and the standard of living of individuals and the size of the disparity in income distribution is not on the national level, but also at the global level as well, without paying attention to the potential resistance for thought the usual classical, Where the greater the returns of factors of production, the consumption will increase, and that the marginal propensity to consume may rise and the rise at rates greater with slices of low-income (the mouths of the poor) wi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 13 2019
Journal Name
Al-kindy College Medical Journal
Outcome Of Surgical Treatment Of Tuberculosis Of The Spine In Patients With Motor Deficits
...Show More Authors

Background: Significant numbers of patients with spinal tuberculosis (TB), especially in developing countries, still present late after disease onset with severe neurological deficits.

Objective:This study was conducted to assess the outcome of surgery in patients with tuberculosis of the spine with motor deficits.

Type of the study: Retrospective study.

Methods: We retrospectively analyzed data obtained in all the patients with severe motor deficits due to spinal TB admitted to and surgically treated in four hospitals in Baghdad/Iraq during the period from January 2012 to January 2014. History, examination, imaging, histological, postoperative, a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 09 2019
Journal Name
Al-kindy College Medical Journal
The Effectiveness of Calcaneal Drilling for Treatment of Resistance Cases of Plantar Heel Pain
...Show More Authors

Background: Plantar heel pain is a clinical syndrome characterized by pain and tenderness beneath the heel which is typically worse in the morning and improves after the first few steps in the day. It is a common and frequently disabling clinical complaint that may be caused by a broad spectrum of osseous or soft tissue disorders.

Objective: To evaluate the effectiveness of an operation of multiple drilling of calcaneum for resistant plantar heel pain syndrome.

Methods: During the period from November 2012 to August 2016, 17 patients (17heels) were enrolled in a cohort clinical study at the orthopedic unit in AL-Sheikh Zayed and Al-Wassity Hospitals.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Mathematical Model of Effect of Number of Pulses of Pulsed Laser on Formation Process of Plasma
...Show More Authors

The effect of number of pulses of pulsed laser on materials is studied analytically, different pulses has been used with the same delay time.  The depth of possible damage to the surface of copper and titanium as well as depth of the crater to both materials were considered in this study.  The study revealed that linear model is only possible when estimating depth of possible damage for copper material, this means that the depth of possible damage increases with the increment of number of laser pulses .As for titanium material, it is found  the relationship is nonlinear.  The depth of possible damage of titanium and copper is not the same, and copper seems to be more predictable than titanium.  
 

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Creating a Conductive Surface of the PMMA by Laser Cladding with DWCNT and MWCNTS
...Show More Authors

This work studied the electrical and thermal surface conductivity enhancement of polymethylmethacrylate (PMMA) clouded by double-walled carbon nanotubes (DWCNTs) and multi-walled carbon nanotube (MWCNTs) by using pulsed Nd:YAG laser. Variable input factors are considered as the laser energy (or the relevant power), pulse duration and pulse repetition rate. Results indicated that the DWCNTs increased the PMMA’s surface electrical conductivity from 10-15 S/m to 0.813×103 S/m while the MWCNTs raised it to 0.14×103 S/m. Hence, the DWCNTs achieved an increase of almost 6 times than that for the MWCNTs. Moreover, the former increased the thermal conductivity of the surface by 8 times and the later by 5 times.

View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Plasma Dynamics and Pulse Shape Rules in Laser Heating of Opaque Targets in Ai
...Show More Authors

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account both plasma dynamics and time variation of incident laser pulse (i.e. pulse shape or profile).Shock tube relations were employed in formulating plasma dynamics over target surface. Gaussian function was chosen in formulating the pulse profile in the present modeling

View Publication Preview PDF
Publication Date
Sun Feb 24 2019
Journal Name
Iraqi Journal Of Physics
Laser energy effect on the properties of ZnS thin films prepared by PLD technique
...Show More Authors

Zinc sulfide (ZnS) thin films were deposited on glass substrates using pulsed laser deposition technique. The laser used is the Q-switched Nd: YAG laser with 1064nm wavelength and 1Hz pulse repetition rate and varying laser energy 700mJ-1000mJ with 25 pulse. The substrate temperature was kept constant at 100°C. The structural, morphological and optical properties of ZnS thin films were characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscope (AFM) and UV-VIS spectrophotometer.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Automatic Co-registration of UAV-Based Photogrammetry and Terrestrial Laser Scanning in Urban Areas
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Fiber Laser Effect on Bond Strength of Titanium implant abutment to Resin Cement
...Show More Authors

Aim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
The performance of a passively Q-switched Cr:YAG4+ in an end- pumped laser system
...Show More Authors

A characteristic study of a passively Q-switched diode pumped solid state laser system is presented in this work. For laser a comparison study for the theoretically calculated results with a simulation results using a software which calculates the Q-switched solid state laser parameters was such as energy, peak power and pulse width were performed. There was a good agreement between our theoretical calculations and the simulation values.

View Publication Preview PDF