Preferred Language
Articles
/
ijl-235
Treatment of Striae Grvidarum as a Type of Striae Distensae Using Long Pulsed Nd:YAG Laser (1064nm) and Fractional CO2 Laser (10600nm)
...Show More Authors

Striae distensae SD or stretch mark are frequent skin lesion that cause considerable aesthetic concern. The 1064nm long pulsed Nd:YAG Laser has been used to promote an increase in dermal collagen and is known to be a Laser that has a high affinity to vascular chromphores. Also by using fractional CO2 Laser 10600nm as an effective modality in treatment of striae distensae SD. It works to stimulate fibroblast and enhance Collagen formation, which is important for newly generated skin tissue.

Objectives: This study aims to verify the efficacy of long pulsed Nd: YAG Laser (1064nm) in the treatment of immature striae distensae (SD) and the efficacy of C02 fractional Laser (10600nm) in treatment of mature striae distensae SD.

Patient and methods: Ten female patients with striae distensae (SD) in the abdomen formed during pregnancy period five of them had immature or recent type of striae were treated by long pulse Nd: YAG Laser 1064nm and the others  five patient had mature type of striae were treated by fractional Co2 Laser (10600nm). This study done in Laser medicine research clinic of institute of Laser for post graduate studies from July 2018 to the end of November 2018. The Age of patients range from 20-40 years old. The Laser parameter used for fractional Co2 Laser (10600nm) was 18 Watts power. Pulse duration 1.3ms, interval 1ms, with distance 1.1mm, the procedure was done under topical anesthesia (EMLA) and the number of sessions done were three sessions of one month interval. The parameter used for long pulse ND: YAG Laser (1064nm) was (51.J) energy in the first session and (70.J) in the second, pulse duration (30ms) frequency (2Hz) with spot size (10mm) with two weeks interval between the sessions, three sessions were used for every patient.

Results: The patient treated by fractional CO2 Laser (10600nm) had a change in the shape and texture of striae distensae SD from first session, and there was noticeable change  occurred in the second session regarding texture and color of striae that became faint. The patient  treated with long pulse Nd:YAG(1064nm) had good result from the second session in which the S.D line became faint with change in texture. With no or mild side effect of treatment, 90% of all patient are fully satisfied with treatment only 10% of patient showed partial satisfaction. 10% of patient had hyperpigmentation.

Conclusion: Striae can be treated by Laser as an effective and safe method with less side effect with good patient satisfaction by long pulse Nd: YAG Laser (1064nm) and fractional Co2 Laser (10600nm) to treat immature and mature striae respectively.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Evaluation the Effect of 805 nm Wavelength Diode Laser on Repair of Mandibular Bone Repair and Skin Incisions in Rabbits
...Show More Authors

The long healing time of bone after tooth extraction in order to construct artificial teeth is uncomfortable to the patient because of aesthetic or masticatory problems in addition to the daily visit to dental clinic. The objective of this study was to evaluate the effect of 805 nm diode laser with long time intervals on repair of bone and skin incisions in rabbits through biochemical, radiological and histological findings. Eighteen New-Zealand rabbits were undergone surgical operations to make a cavity in the bone of the lower jaw, the rabbits were divided into two groups:- Group A (control group) containing nine rabbits. Group B (lased group) containing nine rabbits in which two cavities were done, one on the right side and the other

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
Liver Repair in Rabbits Using 532 nm Nd:YAG Laser; In Vivo Study
...Show More Authors

The main goal of this in vivo study was to evaluate the effect of 532nm Q-switched Nd: YAG Laser in combination with Human Serum Albumin 20% concentration (as a welding aid) on the liver tissue repair clinically, and histologically. The animals used in this study were 21 male rabbits divided into three main groups: control group (3 rabbits), conventionally treated group (9 rabbits) and Laser treated group (9 rabbits). Each two main groups (conventional and laser treated) consist of three sub-groups depending on the response evaluation at three different periods. The Laser group was treated using 532nm Q-switched Nd: YAG laser after adding human serum albumin immediately on the incised liver’s tissue. The energy of was 460mJ, and 4Hz fr

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Effect of Dual Diode Laser: (810,980) nm in Acceleration of Orthodontic Tooth Movement A Case Report
...Show More Authors

Patients are very concerned about the lengthy nature of orthodontic treatment. It is necessary to find a non-invasive way to quicken physiologic tooth movement. This study's objective was to assess the effectiveness of low-intensity laser therapy in shortening the time and discomfort of orthodontic treatment. Experimental work: Using a split-mouth study to compare tooth movement with conventional treatment and laser-accelerated orthodontic tooth movement. A patient presenting with a class II division I malocclusion characterized by the misalignment of the upper and lower teeth as classified by Angle’s molar classification system was indicated to undergo fixed orthodontic appliance orthodontic treatment. The treatment plan involved bila

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 11 2002
Journal Name
Iraqi Journal Of Laser
Investigating the Effects of Carbon Dioxide Laser Fluence on Oral Soft Tissue
...Show More Authors

This study investigates the surgical and thermal effects on oral soft tissues produced by CO2 laser emitting at 10.6 micrometers with three different fluences 490.79, 1226.99 and 1840.4 J/cm2. These effects are specifically; incision depth, incision width and the tissue damage width and depth. The results showed that increasing the fluence and /or the number of beam passes increase the average depths of ablation. Moreover, increasing the fluence and the number of beam passes increase the adjacent tissue damage in width and depth. Surgeons using CO2 laser should avoid multiple pulses of the laser beam over the same area, to avoid unintentional tissue damage.

View Publication Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
The Efficacy of fractional CO2 laser in management of surgical wound scars
...Show More Authors

Background: Atrophic postoperative and traumatic scarring are common cosmetic problems for patients. Combining CO2 laser ablation with a fractional photothermolysis system in a treatment known as ablative fractional resurfacing fulfilling the new demands for a lesser risk of side effects and minimal or no downtime.Objective: To assess the safety and efficacy of ablation fractional CO2 laser treatments for surgical scarring .methods: Twenty one patient ( 14 women, and 7 men ) with various skin types , I to IV , aged 3 to 48 years , presents with 24 scars between June and December 2012 , four patients excluded from study because they are not continued in follow up , the remaining 17 patient completed all 3 treatments & 6 months follow

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Hemorrhoidectomy Using (10600 nm) CO2 Laser
...Show More Authors

Hemorrhoids are one of the most common surgical conditions. The hemorrhoid may cause symptoms that are: bleeding, pain, prolapse, itching, spoilage of feces, and psychologic discomfort. There are many methods for treatment of hemorrhoid like, medical therapy, rubber band ligation, electerocoagulation, stapled hemorrhoidpexy, photocoagulation, sclerothereapy, doppler guided artery ligation, Cryosurgery, and surgery. All methods for treatment of hemorrhoids have advantages, disadvantages, and limitations. Conventional haemorrhoidectomy was the traditional operation for the treatment of hemorrhoids. But recently other modalities of treatment had been used as an alternative operations including CO2 laser haemorrhoidectomy. This work aims to

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
Evaluation of Lithium Disilicate Surface Morphology Treated with Er,Cr:YSGG and Fractional CO2 Laser
...Show More Authors

Abstract: The use of indirect, all-ceramic restorations has grown in popularity among dentists. Studies have demonstrated that for indirect ceramic restorations to be effective over time, cement and ceramic must be bonded in a stable manner. Chemical, mechanical, and laser irradiation are among the methods used to precondition ceramic surfaces in order to increase bond strength.The objective of the study: This study was performed to investigate the roughness values and surface topography of lithium disilicate glass-ceramic treated with conventional methods and different Er,Cr:YSGG, and fractional CO2 laser conditioning parameters.Material and methods:<

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 14 2005
Journal Name
Iraqi Journal Of Laser
Design and Operation of Mini-TEA CO2 Laser and Investigation of Preionization Effect
...Show More Authors

A Mini-TEA CO2 laser system was designed and operated to obtain a pulse at 10.6 μm. Output energy of 30 mJ, with preionization pins, and pulse duration of 100ns were obtained. While an output energy of 6mJ and pulse duration of 100 ns in absence of pre-ionization were obtained. The system was operated with Ernest profile main-discharge electrodes. Dependencies of supply voltage and output laser energy on the pressure inside laser cavity were investigated as well as dependencies of supply voltage and output energy on the main capacitor(8CO2 : 8N2 : 82He :2CO). Efficiency of was calculated to be 4.4%.

View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Treatment of intraoral pyogenic granuloma with diode laser 810-980 nmarch
...Show More Authors

Background: Pyogenic granuloma is a hyperplastic benign tumor. The most common intra-oral site is marginal gingiva. It is often occurred in the second decade of life, it has a strong tendency to recur after simple excision.

The aim of study: to evaluate the therapeutic advantages of diode laser (810-980 nm) in intraoral Pyogenic granuloma management.

Materials and method: A total of 28 patients (14 men and 14 females) were enrolled in this study and had their pyogenic granuloma surgically removed using a diode laser. All of the patients were given local anesthetic and went through the identical surgical procedure (cartridge containing 1 percent lidocaine with epinephrine 1:

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Influence of 805 nm Diode Laser on Plasmid Content of Some Locally Isolated Escherichia coli and Proteus Mirabilis
...Show More Authors

This work aimed to investigate the effect of Diode laser 805 nm on plasmid DNA and RNA
contents of some Gram negative bacteria represented by Escherichia coli and Proteus mirabilis isolates
.Plasmid extraction was done using two methods (Salting out and CTAB method).Different powers and
pulse repetition rates for 805 nm Diode Laser were used to study this effect. Results revealed that the
plasmid profile of the two species were highly affected using (2, 3) W at different frequencies including
5and 10 kHz as compared with 1 kHz while plasmids were gradually disappeared at 1W, 10 kHz. In the
same time the shining of RNA was also decreased gradually then disappeared with increasing powers
especially at 2W and 10 kHz cau

... Show More
View Publication Preview PDF