Preferred Language
Articles
/
ijl-235
Treatment of Striae Grvidarum as a Type of Striae Distensae Using Long Pulsed Nd:YAG Laser (1064nm) and Fractional CO2 Laser (10600nm)
...Show More Authors

Striae distensae SD or stretch mark are frequent skin lesion that cause considerable aesthetic concern. The 1064nm long pulsed Nd:YAG Laser has been used to promote an increase in dermal collagen and is known to be a Laser that has a high affinity to vascular chromphores. Also by using fractional CO2 Laser 10600nm as an effective modality in treatment of striae distensae SD. It works to stimulate fibroblast and enhance Collagen formation, which is important for newly generated skin tissue.

Objectives: This study aims to verify the efficacy of long pulsed Nd: YAG Laser (1064nm) in the treatment of immature striae distensae (SD) and the efficacy of C02 fractional Laser (10600nm) in treatment of mature striae distensae SD.

Patient and methods: Ten female patients with striae distensae (SD) in the abdomen formed during pregnancy period five of them had immature or recent type of striae were treated by long pulse Nd: YAG Laser 1064nm and the others  five patient had mature type of striae were treated by fractional Co2 Laser (10600nm). This study done in Laser medicine research clinic of institute of Laser for post graduate studies from July 2018 to the end of November 2018. The Age of patients range from 20-40 years old. The Laser parameter used for fractional Co2 Laser (10600nm) was 18 Watts power. Pulse duration 1.3ms, interval 1ms, with distance 1.1mm, the procedure was done under topical anesthesia (EMLA) and the number of sessions done were three sessions of one month interval. The parameter used for long pulse ND: YAG Laser (1064nm) was (51.J) energy in the first session and (70.J) in the second, pulse duration (30ms) frequency (2Hz) with spot size (10mm) with two weeks interval between the sessions, three sessions were used for every patient.

Results: The patient treated by fractional CO2 Laser (10600nm) had a change in the shape and texture of striae distensae SD from first session, and there was noticeable change  occurred in the second session regarding texture and color of striae that became faint. The patient  treated with long pulse Nd:YAG(1064nm) had good result from the second session in which the S.D line became faint with change in texture. With no or mild side effect of treatment, 90% of all patient are fully satisfied with treatment only 10% of patient showed partial satisfaction. 10% of patient had hyperpigmentation.

Conclusion: Striae can be treated by Laser as an effective and safe method with less side effect with good patient satisfaction by long pulse Nd: YAG Laser (1064nm) and fractional Co2 Laser (10600nm) to treat immature and mature striae respectively.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Laser Densification of Prepared SiO2 Sol-Gel Thin Films
...Show More Authors

SiO2 nanostructure is synthesized by the Sol-Gel method and thin films are prepared using dip coating technique. The effect of laser densification is studied. X-ray Diffraction (XRD), Fourier Transformation Infrared Spectrometer (FTIR), and Field Emission Scanning Electron Microscopy (FESEM) are used to analyze the samples. The results show that the silica nanoparticles are successfully synthesized by the sol-gel method after laser densification. XRD patterns show that cristobalite structure is observed from diode laser (410 nm) rather than diode laser (532 nm). FESEM images showed that the shape of nano silica is spherical and the particles size is in nano range (? 100 nm). It is concluded that the spherical nanocrystal structure of silica

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Nov 03 2022
Journal Name
Journal Of Materials Engineering And Performance
Influence of Scanning Velocity on a CoCrMoW Alloy Built via Selective Laser Melting: Microstructure, Mechanical, and Tribological Properties
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Jun 03 2016
Journal Name
Al- Kindy College Medical Journal
Laser Diode Enhances Autologous Cartilage Graft's Expansibility
...Show More Authors

Background: Cartilage forms most of the temporary skeleton of the embryo and provides a model in which most bones develop Objective: Using laser therapy to enhance autologous cartilage grafts expansibility and to analyze whether this "enhancement" results in reduced rates of cartilage resorption and greater preservation of normal architectural features compared with "unenhanced" grafts. Type of the study: Cross sectional study. Methods: 24 New Zealand rabbits were divided into two groups (control and treated with 904nm, 10mW diode laser). Auricular cartilage segments measuring 1 cm2 were harvested from both ears of each rabbit, and were implanted in to the subcutaneous region of the left flank. 3 rabbits from each group were anaesthetized a

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 29 2020
Journal Name
Iraqi Journal Of Science
Laser Distance Sensors Evaluation for Geomatics Researches
...Show More Authors

In this study, an approach inspired by a standardized calibration method was used to test a laser distance meter (LDM). A laser distance sensor (LDS) was tested with respect to an LDM and then a statistical indicator explained that the former functions in a similar manner as the latter. Also, regression terms were used to estimate the additive error and scale the correction of the sensors. The specified distance was divided into several parts with percent of longest one and observed using two sensors, left and right. These sensors were evaluated by using the regression between the measured and the reference values. The results were computed using MINITAB 17 package software and excel office package. The accuracy of the results in this wo

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Laser Diode Enhances Autologous Cartilage Graft's Expansibility
...Show More Authors

Background: Cartilage forms most of the temporary skeleton of the embryo and provides a model in which most bones developObjective: Using laser therapy to enhance autologous cartilage grafts expansibility and to analyze whether this "enhancement" results in reduced rates of cartilage resorption and greater preservation of normal architectural features compared with "unenhanced" grafts. Type of the study: Cross sectional study.Methods: 24 New Zealand rabbits were divided into two groups (control and treated with 904nm, 10mW diode laser). Auricular cartilage segments measuring 1 cm2 were harvested from both ears of each rabbit, and were implanted in to the subcutaneous region of the left flank. 3 rabbits from each group were anaesthetized

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Laser Biostimulation Effect on Human Sperm Motility
...Show More Authors

Background: Sperm motility disorder is an important cause of infertility in male, and one of the causes of reduced motility of the sperm is the disorders of the mitochondria because it provides the required energy for sperm motility, Laser biostimulation or low-level laser therapy has a positive effect on the mitochondria and led to increasing the synthesis of ATP. Method: Twenty fresh human semen samples were used in this research study, each sample was separated into two portions, one was used as control which is not exposed to the laser beam and the other was irradiated with the wavelength of 410 nm diode laser with an output power of 100 mW and an exposure time of 60 seconds, then the measurement of

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Laser Finger Print Sensor with Holographic Grating
...Show More Authors

Design and Construction system for recording Finger print by laser, and separted the signal to noise by holographic element, was done. For safety, total reflection lighting ensures hat aser earns an not enter An operators eyes. Holographic diffraction grating was used instead of computer program to contrast images.

View Publication Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
International Journal Of Science And Technology (ijst)
Study of Optical and Structures for TiO2 prepared by Pulse Laser Deposition
...Show More Authors

Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Spatial Response Uniformity of Silicon–Based CdS and PbS Heterojunction Laser Detectors
...Show More Authors

This paper demonstrates the spatial response uniformity (SRU) of two types of heterojunctions (CdS, PbS /Si) laser detectors. The spatial response nonuniformity of these heterojunctions is not significant and it is negligible in comparison with p+- n silicon photodiode. Experimental results show that the uniformity of CdS /Si is better than that of PbS /Si heterojunction

View Publication Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Gamma ray effect on the properties of R590 and C480 laser dyes
...Show More Authors

In the current research, we investigated the absorption spectrum for R590 and C480 dyes in ethanol solvent for different dye solution concentrations of 10-4, 10-5 and 10-6M. These dyes have been prepared and studied before and after gamma irradiation (first, second ionization) using cesium-137 source with absorbed doses of 18.36 Gy (time exposure of 10 days) and 73.44 Gy (with time exposure of 40 days). We noticed that the absorption intensity was decreased with decreasing concentration, before gamma irradiation while the absorption spectrum peak shifted towards the short wavelength (blue shift). It was also found that the intensity of absorption spectrum increased and shifted the absorption spectrum peak towards the long wavelength (red

... Show More
View Publication Preview PDF
Crossref