Preferred Language
Articles
/
ijl-232
A Comparison between Er,Cr:YSGG 2780 nm Laser and Carbide Fissure Bur in Root-End resection
...Show More Authors

Aim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.

Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .

Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recorded. The remaining tooth served as control. Samples were prepared for SEM and examined to evaluate dentinal cracks, cemental damage, roughness, filling material-root canal wall interface.

Statistical Analysis: whenever required, x2 test/Fisher exact and Kruskal–Wallis test were used.

Results: laser result in intradentin cracks in 70% of samples while bur cause intradentin crack in 30% of samples. There was no significant difference between group 1 and 2 regarding the percentage of complete and incomplete cracks. Resection with bur resulted in cemental damage in 70% of samples while resection with laser didn’t result in cemental damage in any of the samples .Evaluation of surface roughness revealed statistically significant difference (P ≤ 0.05). The difference in duration of resection was statistically significant while in recorded temperature was not significant.

Conclusion: Er,Cr:YSGG laser showed higher percentage of intradentinal cracks, no cemental damage, larger gap area ,rougher surface and longer time for resection than bur .There is no elevation of temperature on external root surface.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 26 2023
Journal Name
Arab Science Heritage Journal
أمراء البحر في العصر العباسي إلى نهاية القرن الثالث الهجري/ التاسع الميلادي
...Show More Authors

The Abbasid state inherited many enemies because of the Islamic conquests in the Umayyad era and its geographical extension, which included a number of seas, so it had to direct its energy to preserve the achievements achieved by its predecessors from the Muslims. One of the sea princes who had a role in protecting the coasts of the Abbasid state, especially in the Levant and Egypt.

View Publication Preview PDF
Publication Date
Fri Aug 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Natural Convection Heat Transfer in an Inclined Open-Ended Square Cavity with Partially Active Side Wall
...Show More Authors

This paper reports a numerical study of flow behaviors and natural convection heat transfer characteristics in an inclined open-ended square cavity filled with air. The cavity is formed by adiabatic top and bottom walls and partially heated vertical wall facing the opening. Governing equations in vorticity-stream function form are discretized via finite-difference method and are solved numerically by iterative successive under relaxation (SUR) technique. A computer program to solve mathematical model has been developed and written as a code for MATLAB software. Results in the form of streamlines, isotherms, and average Nusselt number, are obtained for a wide range of Rayleigh numbers 103-106 with Prandtl number 0.71

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
Laser wavelength and energy effect on optical and structure properties for nano titanium oxide prepared by pulsed laser deposit
...Show More Authors

Nano TiO2 thin films on glass substrates were prepared at a constant temperature of (373 K) and base vacuum (10-3 mbar), by pulsed laser deposition (PLD) using Nd:YAG laser at 1064 nm wavelength. The effects of different laser energies between (700-1000)mJ on the properties of TiO2 films was investigated. TiO2 thin films were characterized by X-ray diffraction (XRD) measurements have shown that the polycrystalline TiO2 prepared at laser energy 1000 mJ. Preparation also includes optical transmittance and absorption measurements as well as measuring the uniformity of the surface of these films. Optimum parameters have been identified for the growth of high-quality TiO2 films

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
Serum Pseudocholinesterase as a Biomarker in the Differentiation between Gastric Cancer and Benign Gastric Diseases
...Show More Authors

Background: Worldwide gastric cancer is the fifth most common cancer with poor prognosis. In early stages, it is hard to distinguish gastric cancer from benign gastric diseases, resulting in delayed diagnosis. There is a need to develop a biomarker for differentiating between gastric cancer and benign gastric diseases. Serum cholinesterase is synthesized in liver and released into plasma, and it has an important role in oncogenesis.

Objectives: To determine the correlation between serum cholinesterase activity and gastric cancer, in comparison to benign gastric diseases.

Subjects and Methods: A case control study carried out at Medical City Direct

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
A comparison study of the Structural and magnetic properties of pure Ni metal and NiZnMn ferrite
...Show More Authors

The magnetic properties of a pure Nickel metal and Nickel-Zinc-Manganese ferrites having the chemical formula Ni0.1(Zn0.4Mn0.6)0.9Fe2O4 were studied. The phase formation and crystal structure was studied by using x-ray diffraction which confirmed the formation of pure single spinel cubic phase with space group (Fd3m) in the ferrite. The samples microstructure was studied with scanning electron microstructure and EDX. The magnetic properties of the ferrite and nickel metal were characterized by using a laboratory setup with a magnetic field in the range from 0-500 G. The ferrite showed perfect soft spinel phase behavior while the nickel sample showed higher magnetic loss an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 12 2003
Journal Name
Iraqi Journal Of Laser
Carbon Dioxide Laser Treatment of Viral Warts: A New Approach
...Show More Authors

Verrucae vulgares are commonly encountered. The present work is designed in an attempt to build a systematic procedure for treating warts by carbon dioxide laser regarding dose parameters, application parameters and laser safety.
Patients and Methods: The study done in the department of dermatology in Al-Najaf Teaching Hospital in Najaf, Iraq. Forty-two patients completed the study and follow up period for 3 months. Recalcitrant and extensive warts were selected to enter the study. Carbon dioxide laser in a continuous mode, in non-contact application, with 1 mm spot size was used. The patients were divided into two groups. The first group of patients consisted of 60 lesions divided to 6 equal groups, in whom we use different outputs a

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Plasma Dynamics and Pulse Shape Rules in Laser Heating of Opaque Targets in Ai
...Show More Authors

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account both plasma dynamics and time variation of incident laser pulse (i.e. pulse shape or profile).Shock tube relations were employed in formulating plasma dynamics over target surface. Gaussian function was chosen in formulating the pulse profile in the present modeling

View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The Relationship between the age of the pregnant mother and the values hemoglobin blood and packed cell volume (PCV) in the Third Trimester for different age groups (descriptive study)
...Show More Authors

Pregnancy pose an additional burden on the body of the mother so as to meet their needs and the needs of the fetus and the body's need to iron increases excessively during pregnancy and iron is an essential element for the formation of hemoglobin blood Either hemoglobin is the key ingredient for red blood cells which carries oxygen to parts of the body, alas, most of the pregnant women begin their pregnancy inadequate stocks of iron in their bodies, which does not cover their need and requirement of the fetus, especially in the second and third trimesters of pregnancy When you reach the mother to the period in which they did not have the adequate amount of iron to produce hemoglobin become the mother was anemic So emerged the problem of

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Nanosecond laser pulses for aluminum and copper drilling
...Show More Authors

Nd:YAG laser pulses of 9 nanosecond pulse duration and operating wavelength at 1.06 μm, were utilized to drill high thermal conductivity and high reflectivity aluminum and copper foils. The results showed a dependence of drilled holes characteristics on laser power density and the number of laser pulses used. Drilled depth of 74 ϻm was obtained in aluminum at 11.036×108 W/cm2 of laser power density. Due to its higher melting point, copper required higher laser power density and/or larger number of laser pulses to melt, and a maximum depth of 25 μm was reached at 13.46×108 W/cm2 using single laser pulse.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Therapeutic Advances In Drug Safety
Deferasirox in thalassemia: a comparative study between an innovator drug and its copy among a sample of Iraqi patients
...Show More Authors
Background:

The health care industry is witnessing an increasing trend in the use of generic medicines because of their presumed low cost compared with innovator medicines. The aim of this study was to determine and compare the performance of the copy drug Osveral®and its innovator drug deferasirox (Exjade®).

Methods:

A prospective observational study including 223 patients receiving the branded medicine Exjade®and 101 patients receiving the copy Osveral®was carried out. Data were assessed for a 1-year period and included clinical symptoms, serum ferrit

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref