Preferred Language
Articles
/
ijl-232
A Comparison between Er,Cr:YSGG 2780 nm Laser and Carbide Fissure Bur in Root-End resection
...Show More Authors

Aim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.

Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .

Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recorded. The remaining tooth served as control. Samples were prepared for SEM and examined to evaluate dentinal cracks, cemental damage, roughness, filling material-root canal wall interface.

Statistical Analysis: whenever required, x2 test/Fisher exact and Kruskal–Wallis test were used.

Results: laser result in intradentin cracks in 70% of samples while bur cause intradentin crack in 30% of samples. There was no significant difference between group 1 and 2 regarding the percentage of complete and incomplete cracks. Resection with bur resulted in cemental damage in 70% of samples while resection with laser didn’t result in cemental damage in any of the samples .Evaluation of surface roughness revealed statistically significant difference (P ≤ 0.05). The difference in duration of resection was statistically significant while in recorded temperature was not significant.

Conclusion: Er,Cr:YSGG laser showed higher percentage of intradentinal cracks, no cemental damage, larger gap area ,rougher surface and longer time for resection than bur .There is no elevation of temperature on external root surface.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Evaluation of Laser Doping of Si from MCLT Measurement
...Show More Authors

The measurement of minority carrier lifetime (MCLT) ofp-n Si fabricated with aid of laser doping technique was reported. The measurement is achieved by using open circuit voltage decay (OCVD) technique. The experiment data confirms that the value of MCLT and proftle of Voc decay were very sensitive to the doping laser energy.

View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Laser Densification of Prepared SiO2 Sol-Gel Thin Films
...Show More Authors

SiO2 nanostructure is synthesized by the Sol-Gel method and thin films are prepared using dip coating technique. The effect of laser densification is studied. X-ray Diffraction (XRD), Fourier Transformation Infrared Spectrometer (FTIR), and Field Emission Scanning Electron Microscopy (FESEM) are used to analyze the samples. The results show that the silica nanoparticles are successfully synthesized by the sol-gel method after laser densification. XRD patterns show that cristobalite structure is observed from diode laser (410 nm) rather than diode laser (532 nm). FESEM images showed that the shape of nano silica is spherical and the particles size is in nano range (? 100 nm). It is concluded that the spherical nanocrystal structure of silica

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Jun 12 2006
Journal Name
Iraqi Journal Of Laser
Laser-Induced Low-Resistance Ohmic Contacts on n-Si
...Show More Authors

In the present work, the feasibility of formation near-ideal ohmic behavior of In/n-Si contact efficiently by 300 s duration Nd:YAG pulsed laser processing has been recognized. Several laser pulses energy densities have been used, and the optimal energy density that gives best results is obtained. Topography of the irradiated region was extensively discussed and supported with micrographic illustrations to determine the surface condition that can play the important role in the ohmic contact quality. I-V characteristics in the forward and reverse bias and barrier height measurements have been studied for different irradiated samples to determine the laser energy density that gives best ohmic behavior. Comparing the current results with

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Iraqi Journal Of Physics
Synthesis of Cinnamon Nanoparticles by Using Laser Ablation Technique
...Show More Authors

    The natural  polyphenolic  compound that cinnamon contains is well known for its various biological activities, a broad variety of pharmacological and therapeutic properties.  Diversified biomedical and pharmacological applications benefit from organic nanoparticles with controlled properties. Bioactive and non-toxic, cinnamon nanoparticles (CNPs) can be effective antibacterial agents. Driven by this idea, we prepared spherical CNPs using liquid (PLAL) pulse laser ablation technique and defined those NPs. Using Q-switched Nd : YAG With a wavelength of 1064 nm  pulse laser of constant energy 500 mj , And different laser pulses ( 250 , 500 , 750 , 1000 ) pulse /sec a pure cinnamon target submerged in

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
(?m 10.6) Design study for Reserve of laser CO2
...Show More Authors

In this paper , the CO2 laser receiver system is designed and studied, with wavelength laser 10.6 ?m in room temperature , and to evaluate the performance and discussion it via the package of optical design (ZEMAX), from its output the Spot Diagram is measured through RMS ,and from the Ray fan plot , the aberrations is found which is the normal error for the best focus named (under corrected ) , the other output was the Geometric Encircled Energy in the spot diagram . and found that the radius of spot diagram at 80% (R80%) from the total energy ,and focal shift .The designed system have high efficiency and low cost .

View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2012
Journal Name
Turkish Journal Of Medical Sciences
Histopathological effects of S. xylosus peptidoglycan in comparison to E. coli lipopolysaccharide in the urinary tract of mice
...Show More Authors

he present work, among other previous studies done in our lab, aimed to highlight the histopathological effect of S. xylosus peptidoglycan in comparison to LPS of E. coli. Materials and methods: One hundred and fifty urine specimens were collected from urinary tract infection patients visiting Baghdad hospitals. The histopathological effects of S. xylosus S24 peptidoglycan was studied in the urinary tract of female mice by injecting 5 animal groups at the following concentrations: 1000, 2000, 3000, 4000, and 5000 µg/mL. Another 5 groups were injected with 10, 25, 50, 75, and 100 ng/mL of E. coli (serotype 0128:B12) LPS. Results: Ten isolates were confirmed to be Staphylococcus xylosus. Histopathological study showed different pathological

... Show More
View Publication
Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Kerbala Journal Of Medicine
Polymerase Chain Reaction Testing in Comparison to Culture of Cerebrospinal Fluid for Diagnosis of Bacterial Meningitis in Children
...Show More Authors

View Publication
Publication Date
Mon Dec 01 2008
Journal Name
Saudi Medical Journal
Treatment of perniosis with oral pentoxyfylline in comparison with oral prednisolone plus topical clobetasol ointment in Iraqi patients.
...Show More Authors

AA Noaimi, BM Fadheel, Saudi medical journal, 2008 - Cited by 25

View Publication
Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
The Relation between Bacterial and Heavy Metal Water Pollution and Blood Micronuclei as Biomarkers in the Tigris River Fish
...Show More Authors

The objective of this study is to evaluate the bacterial count and heavy metal concentration of river water on fish micronuclei. Fish and water samples are carried out in 1 May to 1 June 2013 from Tigris River. A total of fifty three fish sample are studied. The bacteriological quality of water showed that the total viable count is ranged from 150×103 to 352×103 cfu/ml and fecal coliform counts was 1250 cell/100ml during the study period. All the metals (Cu, Hg, Pb, and Zn) are within the normal limit, but Cd was slightly elevated in river water samples. The appearance of micronuclei in red blood cells of all fish species is detect , by recording a larger number of it, in ( Abu Alsomere , Hishne , Bannini Kaber al fam & Karkoor

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Crossref
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Relationship between ABO Blood Group Distribution and the incidence of Upper Gastric and Duodenal Ulcer in Iraqi Patients
...Show More Authors

The relationship between blood group antigens and peptic ulcer disease has been widely evaluated in the past, but only one study relating H pylori seroprevalence to ABO blood groups among Iraqi patients with peptic ulcer disease is available. We aimed to evaluate the frequency of peptic ulcer disease among different ABO blood groups in Iraqi patients, and we thought it was worthwhile to try to determine whether these components take some part in disease etiology. One hundred and six patients with peptic ulcer disease (PUD) (43 male and 63 female; mean  age: 48 ± 18 years) who attended Baghdad teaching hospital and Al- Yarmouk teaching hospital endoscopy centers were enrolled , and 238 control Subjects.  Fing

... Show More
View Publication Preview PDF
Crossref (3)
Crossref