Preferred Language
Articles
/
ijl-230
Pulsed Er,Cr:YSGG Laser For Surface Modification of Dental Zerconia Ceramic
...Show More Authors

Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG  Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1.50, 2, 2.50, 3, 3.50, 4) W. And finally group (N): untreated samples representing the control group. Luting cement was applied to laser treated zirconia sample’s surfaces and cured by light for 40 s. Then all sample surfaces were examined under a stereo microscope, for determining the depth mean values of the created pulse holes, for each specimen. The bond between the laser treated zirconia surfaces and the applied resin cement, were examined for all samples by using a universal testing machine, for determination of the shear bond strength values. Six additional specimens: one untreated sample and five other samples that were laser irradiated with the parameters that exhibited the highest shear bond strength values in each treated group, were examined for their average surface roughness by using an atomic force microscope. Another similar six specimens were also examined for their surface morphology, by using a scanning electron microscope. Both surface examination methods were performed by specialized operators. The bond failure modes were also examined by an optical microscope. Results obtained from shear bond strength test and laser pulse depth examination were statistically analyzed. Results: There was significant differences in the shear bond strength values, indicating a clear increase in zirconia-resin cement bonding, especially in group B (30 s, 60 µs, 4W), reaching  (8.63 Mpa). Whereas, the control group had (4.49 Mpa), and an enhanced zirconia surface average roughness, that group E (30 s, 700 µs, 3.5 W) specimen had the highest value (14.5nm), among the six examined specimens. While the control specimen had the least value examined which is (3.05nm). Conclusion: A relation between the cement bonding efficiency and the laser treated zirconia surface roughness, laser pulse depths was detected. The Er,Cr:YSGG laser pulse duration and  power is  crucial parameters in the surface roughness enhancement of the zirconia ceramic.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Experimental and theoretical study of (PVC) nanoparticles prepared by laser ablation in ethanol
...Show More Authors

In this manuscript divide into two parts the first experimental and the second theoretical. The experimental part of polyvinyl chloride (PVC) can be used with aluminum (30%). Nanomaterials are synthesized by a laser pulse melting solution by ethanol. The effect of laser on the structural, morphological, optical, and electrical properties of nanoparticles (PVC) was examined by UV spectroscopy, x-ray diffraction (XRD), electron microscopy (TEM). The theoretical part of the DFT can be used to approximate the generalized gradient of the Perdew, Burke, and Ernzerhof (PBE) / 6-31G (d) groups, which were created using additional Gaussian 09 software through Gaussian 5.08. To build PVC nanocrystal pure which chemical formula [(C2H3Cl)n] and build (

... Show More
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Effect of Gold Nanoparticles and Laser on Platelet, Lymphocytes, and White Blood Cells
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Theoretical Computation of Electron Density in Laser-Induced Carbon Plasma using Anisimov Model
...Show More Authors

In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance

... Show More
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Preparation of thin films of SiCN from gas-phase reaction induced by TEA-CO2 laser and study of their optical properties
...Show More Authors

In this paper, silicon carbonitried thin films were prepared by the method of photolysis of the silane (SiH4) and ethylene (C2H4) gases, with and without ammonia gas (NH3), which is represented by the ratio between the (PNH3) and (PSiH4 + PC2H4 + PNH3), (which assign by the letter X), X has the values (0, 0.13, 0.33). This method carried out by using TEA-CO2 laser, on glass substrate at (375 oC), deposition rate (0.416-0.833) nm/pulse thin film thickness of (500-1000) nm. The optical properties of the films were studied by using Absorbance and Transmittance spectrums in wavelength range of (400-1100) nm, the results showed that the electronic transitions is indirect and the energy gap for the SiCN films increase with increasing of nitrog

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
The Q-switched Nd:YAG laser shock processing effects on mechanical properties of C86400 Cu-Zn alloy: Q-switched Nd:YAG laser shock processing effects on mechanical properties of C86400 Cu-Zn alloy
...Show More Authors

The aim of this paper is to investigate the effects of Nd:YAG laser shock processing (LSP) on micro-hardness and surface roughness of 86400Cu-Zn alloy. X-ray fluorescence technique was used to analyze the chemical composition of this alloy. LSP treatment was performed with a Q-switched Nd: YAG laser with a wavelength of 1064 nm. The results show that laser shock processing can significantly increase. The micro-hardness and surface roughness of the LSP-treated sample. Vickers diamond indenter was used to measure the micro-hardness of all samples with different laser pulse energy and the different number of laser pulses. It is found that the metal hardness can be significantly increased to more than 80% by increasing the laser energy and t

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jul 05 2017
Journal Name
International Journal Of Science And Research (ijsr)
Pacifier Sucking Habit and its Relation to Dental Caries and Type of Feeding Habits among Group of Children (Comparative Study)
...Show More Authors

View Publication
Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (13)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Influence of Er:Cr;YSGG laser Desensitization on SBS of resin cement to dentin
...Show More Authors

Background: Crown preparation of vital teeth involve the removal of a sound tooth structure, and when enamel removed this lead to exposed dentin with an   increase in the number of open dentinal tubules also the diameter of dentinal tubules will increase, furthermore lead to increase movement of fluids inside the tubules all that causes post preparation sensitivity. The aim of this study is to evaluate the effect of desensitizing by Er:Cr:YSGG laser on shear bond strength of prepared tooth and resin cement. Materials and methods: Thirty sound maxillary premolars, grouped into three groups(n=10). Group A is the control group, group B irradiated by Er:Cr:YSGG laser with (0.25 W, 20 Hz, 1

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
The Efficacy of Er:YAG Laser on Intrapulpal Temperature Rise of Class V Cavity Preparation
...Show More Authors

The objective of this study is to determine the efficacy of class V Er:YAG laser (2940 nm) cavity preparation and conventional bur cavity preparation regarding Intrapulpal temperature rise during cavity preparation in extracted human premolar teeth. Twenty non carious premolar teeth extracted for orthodontic purposes were used and class V cavity preparation was applied both buccal and lingual sides for each tooth .Samples were equally grouped into two major groups according to cavity depth (1mm and 2mm). Each major group was further subdivided into two subgroupsof ten teeth for each (twenty cavities for each subgroup). TwinlightEr:YAG laser (2940 nm) with 500mJ pulse energy, P.R.R of 10 Hz and 63.69 J/cm2 energy density was used. The ana

... Show More
View Publication Preview PDF
Publication Date
Wed May 15 2024
Journal Name
Iraqi Journal Of Applied Physics
Effect of Solvent on Spectroscopic Characteristics and Energy Transfer Processes of Some Laser Dyes
...Show More Authors

Scopus (1)
Scopus