Preferred Language
Articles
/
ijl-230
Pulsed Er,Cr:YSGG Laser For Surface Modification of Dental Zerconia Ceramic
...Show More Authors

Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG  Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1.50, 2, 2.50, 3, 3.50, 4) W. And finally group (N): untreated samples representing the control group. Luting cement was applied to laser treated zirconia sample’s surfaces and cured by light for 40 s. Then all sample surfaces were examined under a stereo microscope, for determining the depth mean values of the created pulse holes, for each specimen. The bond between the laser treated zirconia surfaces and the applied resin cement, were examined for all samples by using a universal testing machine, for determination of the shear bond strength values. Six additional specimens: one untreated sample and five other samples that were laser irradiated with the parameters that exhibited the highest shear bond strength values in each treated group, were examined for their average surface roughness by using an atomic force microscope. Another similar six specimens were also examined for their surface morphology, by using a scanning electron microscope. Both surface examination methods were performed by specialized operators. The bond failure modes were also examined by an optical microscope. Results obtained from shear bond strength test and laser pulse depth examination were statistically analyzed. Results: There was significant differences in the shear bond strength values, indicating a clear increase in zirconia-resin cement bonding, especially in group B (30 s, 60 µs, 4W), reaching  (8.63 Mpa). Whereas, the control group had (4.49 Mpa), and an enhanced zirconia surface average roughness, that group E (30 s, 700 µs, 3.5 W) specimen had the highest value (14.5nm), among the six examined specimens. While the control specimen had the least value examined which is (3.05nm). Conclusion: A relation between the cement bonding efficiency and the laser treated zirconia surface roughness, laser pulse depths was detected. The Er,Cr:YSGG laser pulse duration and  power is  crucial parameters in the surface roughness enhancement of the zirconia ceramic.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Aug 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Evaluation of Laser Doping of Si from MCLT Measurement
...Show More Authors

The measurement of minority carrier lifetime (MCLT) ofp-n Si fabricated with aid of laser doping technique was reported. The measurement is achieved by using open circuit voltage decay (OCVD) technique. The experiment data confirms that the value of MCLT and proftle of Voc decay were very sensitive to the doping laser energy.

View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic analysis of magnesium-aluminum alloys by laser induced breakdown spectroscopy
...Show More Authors

In this work, the spectra of plasma glow produced by Nd:YAG laser operated at 1.064 μm on Al-Mg alloys with same molar ratio samples in air were analyzed by comparing the atomic lines of aluminum and magnesium with that of strong standard lines. The effect of laser energies on spectral lines, produced by laser ablation, were investigated using optical spectroscopy, the electron density was measured utilizing the Stark broadening of magnesium-aluminum lines and the electron temperature was calculated from the standard Boltzmann plot method. The results that show the electron temperature increases in magnesium and aluminum targets but decreases in magnesium: aluminum alloy target, also show the electron density increase all the aluminum,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
Study the Impact of Silica Nanoparticles on the Properties of Several Dyes for the Fabrication of a Random Laser Gain Medium
...Show More Authors

Random laser gain media is synthesized with different types of dye at the same concentration (1×10-3 M) as an active material and silicon dioxide NPs (silica SiO2) as scatter centers through the Sol-Gel technique. The prepared samples are tested with UV–Vis spectroscopy, Fluorescence Spectroscopy, Field Emission Scanning Electron Microscopy (FESEM), and Energy Dispersive X-ray Diffraction (EDX). The end result demonstrates that doped dyes with silica nanoparticles at a concentration of 0.0016 mol/ml have lower absorbance and higher fluorescence spectra than pure dyes. FESEM scans revealed that the morphology of nanocrystalline silica is clusters of nano-sized spherical particles in the range (25-67) nm. It is con

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 12 2017
Journal Name
Journal Of Agricultural And Food Chemistry
Using Standing Gold Nanorod Arrays as Surface-Enhanced Raman Spectroscopy (SERS) Substrates for Detection of Carbaryl Residues in Fruit Juice and Milk
...Show More Authors

View Publication
Scopus (116)
Crossref (106)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Process Safety And Environmental Protection
Applications of advanced oxidation processes (Electro‑Fenton and sono‑electro‑Fenton) for COD removal from hospital wastewater: Optimization using response surface methodology
...Show More Authors

View Publication
Scopus (42)
Crossref (41)
Scopus Clarivate Crossref
Publication Date
Sat Aug 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Marginal Fitness of CAD/CAM All Ceramic Crowns Constructed by Two Typesof Direct Digitization Techniques (An In Vitro Study)
...Show More Authors

Background: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sa

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode
...Show More Authors

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Aug 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Influence of Different Fabrication Techniques and Preparation Designs on the Marginal Adaptation of Ceramic Veneers (An In vitro Comparative Study)
...Show More Authors

Background: Ceramic veneers represent the treatment of choice in minimally invasive esthetic dentistry; one of the critical factors in their long term success is marginal adaptation. The aim of the present study is to evaluate the marginal gap of ceramic veneers by using two different fabrication techniques and two different designs of preparation. Material and methods: A typodont maxillary central incisor used in the preparation from which metal dies were fabricated, which were in turn used to make forty stone dies. The dies divided into four experimental groups, each group had ten samples: A1: prepared with butt-joint incisal reduction and restored with IPS e.max CAD, A2: prepared with overlapped incisal reduction and restored with IPS e.

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Controlling the wavelength of a high power diode laser using thermoelectric cooler
...Show More Authors

The present work includes a design and characteristics study of a controlling the wavelength of high power diode laser by thermoelectric cooler [TEC] . The work includes the operation of the [TEC] to control the temperature of the diode laser between ( 0- +30) °C by changing the resistance of thermistor. We can control a limited temperature of a diode laser by changing the phase cooling between hot and cold faces of the diode, this process can be attempted by comparator type [LM –311] .The theoretical results give a model for controlling the temperature with, the suitable wavelength.

View Publication Preview PDF