Preferred Language
Articles
/
ijl-217
Spider Veins Treatment using 1064 nm Long-Pulse Nd:YAG Laser
...Show More Authors

spider veins are clusters of Ectatic venules & are common finding on the lower limbs generally believed to be caused by multiple factors, including genetic predisposition, hormonal factors, gravity, occupation, pregnancy, becoming increasingly apparent with age, and trauma. Therapeutic options include sclerotherapy, surgical procedures, and treatment with different laser systems.

 Objectives: The purpose of the study was to evaluate the efficacy and safety of long pulsed (Nd:YAG) laser emitting at 1064nm in the treatment of spider veins.

Patients, Materials and Methods: This prospective study was done in the laser medicine research clinics of the Institute of laser for postgraduate Studies / University of Baghdad from September 2016 until the end of December 2016. The study included ten patients between the ages of 22 to 55 years suffered from spider veins of the lower limbs. They were treated with a long pulsed (Nd:YAG) laser in a non contact technique using the following laser parameters (wavelength 1064 nm ,energy 30-73 J, pulse duration 10-30 ms, frequency 2Hz, spot diameter 3-7mm ). Laser therapy was performed on day zero and day fourteen. Clinical assessments were carried out before laser therapy and immediately after the first laser therapy, 2 weeks, 4 weeks, and 6 weeks later.

 Results: Results showed that there was a remarkable improvement for all patients after the second treatment. Six patients (60%) showed a complete disappearance of the spider veins and there was an improvement for four patients (40%) with no significant intraoperative and postoperative pain or complications, within short operative time.

Conclusion: The long pulsed (Nd:YAG) laser (1064 nm) is an effective and safe treatment option for lower limbs spider veins

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Strength Improvement of Clay Soil by Using Stone Powder
...Show More Authors

Soil stabilization with stone powder is a good solution for the construction of subgrade for road way and railway lines, especially under the platforms and mostly in transition zones between embankments and rigid structures, where the mechanical properties of supporting soils are very influential. Stone powder often has a unique composition which justifies the need for research to study the feasibility of using this stone powder type for ground improvement applications. This paper presents results from a comprehensive laboratory study carried out to investigate the feasibility of using stone powder for improvement of engineering properties of clays.

The stone powder contains bassanite (CaSO4. ½ H

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 30 2025
Journal Name
Industrial Laboratory. Diagnostics Of Materials
Simultaneous determination of metronidazole and thiamine using UV-spectroscopy
...Show More Authors

The development of analytical techniques is required for the accurate and comprehensive detection and measurement of antibiotic contamination in the environment. Metronidazole is a common antibacterial, antiprotozoal, and antibiotic drug. Thiamine is a vital biological and medicinal ingredient that is involved in the metabolism of proteins, fats, and carbohydrates that produce energy. The study aims to identify the drugs in a mixture without separation to provide more information to confirm if a drug is present in a combination. Metronidazole and thiamine are two examples of pharmaceutical and environmental samples that can be identified using spectrophotometric techniques because of their low cost and simplicity of use. The operati

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Desulfurization of gas oil using a solar photocatalytic microreactor
...Show More Authors

The present work is devoted to investigate the performance of a homemade Y-shape catalytic microreactor for degradation of dibenzothiophene (DBT), as a model of sulphur compounds including in gas oil, utilizing solar incident energy. The microchannel was coated with TiO2 nanoparticles which were used as a photocatalyst. Performance of the microreactor was investigated using different conditions (e.g., DBT concentration, LHSV, operating temperature, and (H2O2/DBT) ratio). Our experiments show that, in the absence of UV light, no reaction takes place. The results revealed that outlet concentration of DBT decreases as the mean residence time in the microreactor increases. Also, it was noted that operating temperature s

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
PREPARATION OF PVC HOLLOW FIBER MEMBRANE USING (DMAC/ACETONE)
...Show More Authors

Membrane manufacturing system was operated using dry/wet phase inversion process. A sample of hollow fiber membrane was prepared using (17% wt PVC) polyvinyl chloride as membrane material and N, N Dimethylacetamide (DMAC) as solvent in the first run and the second run was made using (DMAC/Acetone) of ratio 3.4 w/w. Scanning electron microscope (SEM) was used to predict the structure and dimensions of hollow fiber membranes prepared. The ultrafiltration experiments were performed using soluble polymeric solute poly ethylene glycol (PEG) of molecular weight (20000 Dalton) 800 ppm solution 25 °C temperature and 1 bar pressure. The experimental results show that pure water permeation increased from 25.7 to 32.2 (L/m2.h.bar) by adding aceton

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 30 2018
Journal Name
Baghdad Science Journal
Electronic Structure of Copper Antimony Using Compton Scattering Technique
...Show More Authors

In this paper we present the first ever measured experimental electron momentum density of Cu2Sb at an intermediate resolution (0.6 a.u.) using 59.54 keV 241Am Compton spectrometer. The measurements are compared with the theoretical Compton profiles using density function theory (DFT) within a linear combination of an atomic orbitals (LCAO) method. In DFT calculation, Perdew-Burke-Ernzerhof (PBE) scheme is employed to treat correlation whereas exchange is included by following the Becke scheme. It is seen that various approximations within LCAO-DFT show relatively better agreement with the experimental Compton data. Ionic model calculations for a number of configurations (Cu+x/2)2(Sb-x) (0.0≤x≤2.0) are also performed utilizing free a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Frequency analyses of human voice using fast Fourier transform
...Show More Authors

Quantitative analysis of human voice has been subject of interest and the subject gained momentum when human voice was identified as a modality for human authentication and identification. The main organ responsible for production of sound is larynx and the structure of larynx along with its physical properties and modes of vibration determine the nature and quality of sound produced. There has been lot of work from the point of view of fundamental frequency of sound and its characteristics. With the introduction of additional applications of human voice interest grew in other characteristics of sound and possibility of extracting useful features from human voice. We conducted a study using Fast Fourier Transform (FFT) technique to analy

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
International Journal Of Advanced Research In Computer Science And Software Engineering
Real Time Motion Detection in Surveillance Camera Using MATLAB
...Show More Authors

Surveillance cameras are video cameras used for the purpose of observing an area. They are often connected to a recording device or IP network, and may be watched by a security guard or law enforcement officer. In case of location have less percentage of movement (like home courtyard during night); then we need to check whole recorded video to show where and when that motion occur which are wasting in time. So this paper aims at processing the real time video captured by a Webcam to detect motion in the Scene using MATLAB 2012a, with keeping in mind that camera still recorded which means real time detection. The results show accuracy and efficiency in detecting motion

Preview PDF
Publication Date
Tue Jul 31 2018
Journal Name
Journal Of Theoretical And Applied Information Technology
Classification and monitoring of autism using svm and vmcm
...Show More Authors

Autism is a lifelong developmental deficit that affects how people perceive the world and interact with each others. An estimated one in more than 100 people has autism. Autism affects almost four times as many boys than girls. The commonly used tools for analyzing the dataset of autism are FMRI, EEG, and more recently "eye tracking". A preliminary study on eye tracking trajectories of patients studied, showed a rudimentary statistical analysis (principal component analysis) provides interesting results on the statistical parameters that are studied such as the time spent in a region of interest. Another study, involving tools from Euclidean geometry and non-Euclidean, the trajectory of eye patients also showed interesting results. In this

... Show More
Preview PDF
Scopus (3)
Scopus
Publication Date
Thu Dec 01 2022
Journal Name
Iraqi Journal Of Science
PLAGIARISM DETECTION SYSTEM IN SCIENTIFIC PUBLICATION USING LSTM NETWORKS
...Show More Authors

Scopus (3)
Scopus
Publication Date
Mon Sep 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of Methyl Orange from Wastewater by using Biochar
...Show More Authors

The biochar prepared from sawdust raw material was applied in this study for the treatment of wastewater polluted with methyl orange dye. The effect of pH (2-11), initial concertation (50-250 mg/L) and time were studied. The isotherm of Langmuir, Frendluch and temkin models studied. The Langmuir model was the best to explain the adsorption process, maximum uptake was 136.67 mg/g at 25Co of methyl orange dye. Equilibrium reached after four hours of contact for most adsorbents.The values of thermodynamic parameters ∆G were negative at various temperatures, so the process spontaneous, while ∆H values were 16683 j/mol and ∆S values was 60.82 j/mol.k.

View Publication Preview PDF
Crossref (15)
Crossref