Preferred Language
Articles
/
ijl-208
Stress Urinary Incontinence Treatment Using Vaginal Fractional CO2 Laser (10600nm)
...Show More Authors

Stress urinary incontinence (SUI) is involuntary urine leakage during activities that increase abdominal pressure such as coughing, sneezing and lifting of heavy weights. This is a very common disorder among women with history of multiple vaginal deliveries with an obstructed labor. SUI is considered one of the most distressing problems, especially for younger women, with severe quality of life implications, it caused by the loss of urethral support, usually as a consequence of the supporting structural muscles in the pelvis.

Objective: To prove and demonstrate the effect of a fractional CO2 micro-ablative laser (10600nm) in intra vaginal therapy for treating SUI and achieve a clinical improvement of the urogenital system support.

Methods: This is a prospective, observational study which was conducted over six month from the 1st . of July to 29th of December 2016 in Consultation Gynecologist Clinic in Al-Hila city, Iraq, in patients who complain of SUI. Twenty female patients were included in the study, their age ranged from 30- 69 year, at range (49.5 year ) fifteen patient delivered vaginally, two delivered by cesarean section, two had combined delivery and one was Nulliparous ,all of them received the same treatment protocol. Detailed history about continence assessment, quality of life and sexuality before and after therapy. The fractional CO2 Aphrodite laser was used. The parameters used in each session were energy/(dot)pixel 119.4mJ, pulse duration 900 μs, frequancy1000Hz, and exposure time 300ms /shot with average of shots 34 and in range 26-42, in three sessions four weeks apart between them. The patients were followed for three months started from the beginning of the second session to one month after the last session.

 Results: Thirty-five percent of patients 35%(n=7) were cured ,and these 35% included all patients delivered by cesarean section and one third of patients who delivered vaginally and extensively most of patients were 60%(n=12) improved of their SUI. Patient reported no leakage any more while coughing or sneezing. Only 5%(n=1) not responded was menopause women.

Conclusions: This study shows that micro-ablative fractional CO2 laser is effective can produce a remodeling of vaginal connective tissue without causing damage to surrounding tissue and the group of patients with continence disorder without vaginal delivery achieved marked improvement .

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Apr 01 2011
Journal Name
Journal Of Engineering
Membranes separation process for oily wastewater treatment
...Show More Authors

Pilot-scale dead end microfiltration membranes were carried out to determine the feasibility of the process for treating the oily wastewater which discharge from some Iraqi factories such as power station of south of Baghdad and the general company of petrochemical industries. Polypropylene membranes (cylindrical shape) with different pore diameters (1 and 5 micron) were used to conduct the study on micromembrane process. The variables studied are oil concentration (100 – 1000 ppm), feed flow rate (20 – 40 l/h), operating temperature (31 – 50°C) and time (0 – 3 h). It was found that the flux increases with increasing feed flow rate, temperature and pore size of membrane, and decreases with increasing oil concentration and operating

... Show More
Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Treatment of polycyclic armoatic hydrocarbone in agriculture
...Show More Authors

Despite the multiple sources of polycyclic compounds in the agricultural environment, this study suggests that it is possible to adopt the events of plants and their associated microorganisms in the soil, such as mushrooms and bacteria in the decomposition of these compounds can also use harvested plants such as barley and alfalfa grown for animal feed

View Publication Preview PDF
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Optimization of Biochemical Treatment of Tannery Wastewater
...Show More Authors

The present work is concerned with the finding of the optimum conditions for biochemical wastewater treatment for a local tannery. The water samples were taken from outline areas (the wastewater of the chrome and vegetable tannery) in equal volumes and subjected to sedimentation, biological treatment, and chemical and natural sedimentation treatment.
The Box-Wilson method of experimental design was adopted to find useful relationships between three operating variables that affect the treatment processes (temperature, aeration period and phosphate concentration) on the Biochemical Oxygen Demand (BOD5).
The experimental data collected by this method were successfully fitted to a second order polynomial mathematical model. The most fa

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 30 2019
Journal Name
College Of Islamic Sciences
Extremism in religion Causes, effects and treatment
...Show More Authors

Praise be to God, Lord of the worlds, and prayers and peace be upon His messenger, the mercy of the worlds.
As for after ....
It is clear from the legal texts in the Noble Qur’an and the Sunnah of the Prophet, that Islam is a method that interferes in everything in beliefs, worship, behavior and transactions, and it forbids excess and extremism and mistrust of people and looking at them through a black lens, self-conceit and contempt of others.
In our research, we will try, God willing, to study the phenomenon of religious extremism with its comprehensive dimensions, the position of Islam on it through the verses and hadiths discussed by it, and the diagnosis of the reasons for its emergence and emergence, because if we learn

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Engineering
Experimental Evaluation Use of Semifluidized Bed Adsorber for the Treatment of P-chlorophenol and O-cresol in Wastewater using Activated Carbon as Adsorbent
...Show More Authors

In the present work the performance of semifluidized bed adsorber was evaluated for removal of phenolic compound from wastewater using commercial activated carbon as adsorbent. P-chlorophenol (4-Chlorophenol) and o-cresol (2-methylphenol) was selected as a phenolic compound for that purpose. The phenols percent removal, in term of breakthrough curves were studied as affected by hydrodynamics limitations which include minimum and maximum semifluidization velocities and packed bed formation in the column by varying various parameters such as inlet liquid superficial velocity (from Uminsf to 8Uminsf m/s), and retaining grid (sometimes referred to as adsorbent loading) to initial static bed height ratio (from 3-4.5). In

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Effect of the electric field on drilling Brass by Laser
...Show More Authors

The research include a pulsed Nd: YAG Laser with (300µs) pulse duration in the TEM00 mode at (1.06µm) wavelength for energies between (0.5-3) J was employed to drill Brass material which is use in industrial applications. The process of drill was assisted by an electric field. This resulted in an increase in the hole aspect ratio by the value (45%) and decrease in the hole taper by the value (25%) of its value under ordinary drilling conditions using the same input energy.

View Publication Preview PDF
Crossref
Publication Date
Fri May 02 2014
Journal Name
Remote Sensing
Calibrated Full-Waveform Airborne Laser Scanning for 3D Object Segmentation
...Show More Authors

Segmentation of urban features is considered a major research challenge in the fields of photogrammetry and remote sensing. However, the dense datasets now readily available through airborne laser scanning (ALS) offer increased potential for 3D object segmentation. Such potential is further augmented by the availability of full-waveform (FWF) ALS data. FWF ALS has demonstrated enhanced performance in segmentation and classification through the additional physical observables which can be provided alongside standard geometric information. However, use of FWF information is not recommended without prior radiometric calibration, taking into account all parameters affecting the backscatter energy. This paper reports the implementation o

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Nanosecond Nd: YAG Laser Surface Cleaning of Metals and Marbles
...Show More Authors

Laser cleaning of materials’ surfaces implies the removal of deposited pollutants without affecting the material. Nanosecond Nd:YAG pulsed laser, operating at 1064 nm and 532nm, was utilized. Different laser intensities and number of pulses were used on metallic and non-metallic surfaces under O2 and Ar environments to remove metal oxide and crust. Cleaning efficiency was studied by optical microscope. The results indicated the superiority of 1064 nm over the 532 nm wavelength without any detectable damage to materials’ surfaces. Marble cleaned in Oxygen gas environment was better than in Ar gas.

View Publication Preview PDF
Publication Date
Fri Jun 18 2004
Journal Name
Iraqi Journal Of Laser
Laser Induced Fluorescence of 1,3 Benzodioxole in a Supersonic Jet
...Show More Authors

Fluorescence excitation by Nd:YAG pumped dye laser and single vibrational level fluorescence
spectra of 1,3 benzodioxole in a supersonic jet have been obtained and interpreted. The previous assignment of
the 0 0
0 band was incorrect. In addition, many other bands involving n20 and n19 vibrations of a2 symmetry were
confirmed. As far as a1 totally symmetric vibration is concerned. The n14 was assigned to be located in the fivemembered
ring whereas n13 seem to be located in the benzene ring as a result of the electronic transition in the
benzene ring which affects n13 and not n14 wavenumber.

View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Electronic diagnostics system for the analysis of laser beam profile
...Show More Authors

In this work the analysis of laser beam profile system ,using a two dimensional CCD (Charge Coupled Device) arrays, is established. The system is capable of producing video graphics that give a two dimensional image of laser beam. The video graphics system creates color distribution that represent the intensity distribution of the laser beam or the energy profile of the beam. The software used is capable of analyzing and displaying the profile in four different methods that is , color code intensity contouring , intensity shareholding, intensity cross section along two dimension x-y, and three dimensional plot of the beam intensity given in the same display.

View Publication Preview PDF