Preferred Language
Articles
/
ijl-208
Stress Urinary Incontinence Treatment Using Vaginal Fractional CO2 Laser (10600nm)
...Show More Authors

Stress urinary incontinence (SUI) is involuntary urine leakage during activities that increase abdominal pressure such as coughing, sneezing and lifting of heavy weights. This is a very common disorder among women with history of multiple vaginal deliveries with an obstructed labor. SUI is considered one of the most distressing problems, especially for younger women, with severe quality of life implications, it caused by the loss of urethral support, usually as a consequence of the supporting structural muscles in the pelvis.

Objective: To prove and demonstrate the effect of a fractional CO2 micro-ablative laser (10600nm) in intra vaginal therapy for treating SUI and achieve a clinical improvement of the urogenital system support.

Methods: This is a prospective, observational study which was conducted over six month from the 1st . of July to 29th of December 2016 in Consultation Gynecologist Clinic in Al-Hila city, Iraq, in patients who complain of SUI. Twenty female patients were included in the study, their age ranged from 30- 69 year, at range (49.5 year ) fifteen patient delivered vaginally, two delivered by cesarean section, two had combined delivery and one was Nulliparous ,all of them received the same treatment protocol. Detailed history about continence assessment, quality of life and sexuality before and after therapy. The fractional CO2 Aphrodite laser was used. The parameters used in each session were energy/(dot)pixel 119.4mJ, pulse duration 900 μs, frequancy1000Hz, and exposure time 300ms /shot with average of shots 34 and in range 26-42, in three sessions four weeks apart between them. The patients were followed for three months started from the beginning of the second session to one month after the last session.

 Results: Thirty-five percent of patients 35%(n=7) were cured ,and these 35% included all patients delivered by cesarean section and one third of patients who delivered vaginally and extensively most of patients were 60%(n=12) improved of their SUI. Patient reported no leakage any more while coughing or sneezing. Only 5%(n=1) not responded was menopause women.

Conclusions: This study shows that micro-ablative fractional CO2 laser is effective can produce a remodeling of vaginal connective tissue without causing damage to surrounding tissue and the group of patients with continence disorder without vaginal delivery achieved marked improvement .

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 30 2013
Journal Name
Iraqi Journal Of Science
Protective Effect of Vitamin A against Oxidative Stress Caused by Methotrexate
...Show More Authors

Methotrexate (MTX), a folate antagonist agent, is mainly used in treatment of malignant tumors and autoimmune diseases. The present study was undertaken to determine whether antioxidant vitamin (vitamin A) could ameliorate methotrexate induced oxidative stress in male rabbits. Twenty male rabbits were randomly assigned into four groups. Group 1: control group, Group 2: MTX-treated group (received 20 mg/kg MTX intraperitoneally), Group 3: Vit.A treated group received 5000 IU Vit.A orally) and Group 4: MTX+Vit.A treated group received MTX 20 mg/kg plus 5000 IU vit.A). After 4 weeks of treatment, blood samples were collected by cardiac puncture to determine the serum malondialdehyde (MDA), as a good indicator for lipid peroxidation and

... Show More
Publication Date
Wed Jan 01 2020
Journal Name
Society Of Petroleum Engineering
Stress-dependent petrophysical properties of high heterogeneous carbonate tight oil reservoirs
...Show More Authors

Scopus (8)
Scopus
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
On Estimation of the Stress – Strength Reliability Based on Lomax Distribution
...Show More Authors
Abstract<p>The present paper concerns with the problem of estimating the reliability system in the stress – strength model under the consideration non identical and independent of stress and strength and follows Lomax Distribution. Various shrinkage estimation methods were employed in this context depend on Maximum likelihood, Moment Method and shrinkage weight factors based on Monte Carlo Simulation. Comparisons among the suggested estimation methods have been made using the mean absolute percentage error criteria depend on MATLAB program.</p>
View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Engineering
Generation and Experimental Stress Analysis of Elliptical Gears with Combined Teeth
...Show More Authors

In this study, generation of elliptical gears with different teeth profiles of crowned involute, double circular arc (DCA), and combined (crowned involute with DCA) has been developed. The resulting mathematical equations have been computerized and feed to CNC end mill machine to manufacture elliptical gear models with different profiles. These models are investigated in plane polariscope to show the resulting stresses under certain load. Comparison of photo-elastic stress results shows that combined elliptical gears with DCA side as a loaded side have a minimum resulting contact stress with a reduction percentage of 40% compare with contact stresses in counterpart elliptical gear of involute profile (which is commonly u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
An Analytical Solution for the Maximum Tensile Stress and Stress Concentration Factor Investigations for Standard, Asymmetric fillets, Asymmetric Pressure Angle and Profile Shifted Helical and Spur Gears
...Show More Authors

This research introduces a developed analytical method to determine the nominal and maximum tensile stress and investigate the stress concentration factor. The required tooth fillets parametric equations and gears dimensions have been reformulated to take into account the asymmetric fillets radiuses, asymmetric pressure angle, and profile shifting non-standard modifications. An analytical technique has been developed for the determination of tooth weakest section location for standard, asymmetric fillet radiuses, asymmetric pressure angle and profile shifted involute helical and spur gears. Moreover, an analytical equation to evaluate gear tooth-loading angle at any radial distance on the involute profile of spur and hel

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Aug 01 2014
Journal Name
Int. J. Mod. Eng. Res
Exact solutions for MHD flow of a viscoelastic fluid with the fractional Burgers’ model in an annular pipe
...Show More Authors

This paper presents an analytical study for the magnetohydrodynamic (MHD) flow of a generalized Burgers’ fluid in an annular pipe. Closed from solutions for velocity is obtained by using finite Hankel transform and discrete Laplace transform of the sequential fractional derivatives. Finally, the figures are plotted to show the effects of different parameters on the velocity profile.

View Publication
Publication Date
Thu Sep 01 2022
Journal Name
Iaes International Journal Of Robotics And Automation
Implementation of a complex fractional order proportional-integral-derivative controller for a first order plus dead time system
...Show More Authors

This paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi

... Show More
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Laser Biostimulation Effect on Human Sperm Motility
...Show More Authors

Background: Sperm motility disorder is an important cause of infertility in male, and one of the causes of reduced motility of the sperm is the disorders of the mitochondria because it provides the required energy for sperm motility, Laser biostimulation or low-level laser therapy has a positive effect on the mitochondria and led to increasing the synthesis of ATP. Method: Twenty fresh human semen samples were used in this research study, each sample was separated into two portions, one was used as control which is not exposed to the laser beam and the other was irradiated with the wavelength of 410 nm diode laser with an output power of 100 mW and an exposure time of 60 seconds, then the measurement of

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Laser Finger Print Sensor with Holographic Grating
...Show More Authors

Design and Construction system for recording Finger print by laser, and separted the signal to noise by holographic element, was done. For safety, total reflection lighting ensures hat aser earns an not enter An operators eyes. Holographic diffraction grating was used instead of computer program to contrast images.

View Publication Preview PDF
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Laser Diode Enhances Autologous Cartilage Graft's Expansibility
...Show More Authors

Background: Cartilage forms most of the temporary skeleton of the embryo and provides a model in which most bones developObjective: Using laser therapy to enhance autologous cartilage grafts expansibility and to analyze whether this "enhancement" results in reduced rates of cartilage resorption and greater preservation of normal architectural features compared with "unenhanced" grafts. Type of the study: Cross sectional study.Methods: 24 New Zealand rabbits were divided into two groups (control and treated with 904nm, 10mW diode laser). Auricular cartilage segments measuring 1 cm2 were harvested from both ears of each rabbit, and were implanted in to the subcutaneous region of the left flank. 3 rabbits from each group were anaesthetized

... Show More
View Publication Preview PDF