Preferred Language
Articles
/
ijl-202
Electronically Implementation and Detection of Pulse Laser from Continuous Laser Diode
...Show More Authors

This research aims to design a high-speed laser diode driver and photodetector, the result is the
design of the high-speed laser diode driver with a short pulse of 10 ns at 30 KHz frequency and the
delivered maximum pulse voltage is 5.5 mV. Also, its optical output power of the laser diode driver is
about 2.529 mW for the centroied wavelength 1546.7 nm with FWHM of 286 pm and (1270-1610) nm.
The design of the circuit based on bipolar transistor where the input pulse signal is simply generated by
an arduino kit with 15 kHz frequency and then compensated to trigger to small signal amplifier which
was is simply NPN C3355 transistor and the output is a current driver to the laser diode. OptiSystem
software and Electronic Workbench tools were used for the design of high speed laser diode diver and its
simulation

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 10 2007
Journal Name
Iraqi Journal Of Laser
Evaluation of breast mass excision by 810 nm diode laser
...Show More Authors

Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode
...Show More Authors

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 31 2018
Journal Name
Iraqi Journal Of Science
Structure and Morphological Properties of In2O3 Nanostructure Prepared by Pulse Laser Ablation Method
...Show More Authors

     A colloidal indium oxide (In2O3) nanoparticles (NPs) were synthesized pulsed laser ablation (PLA) of  indium  plate placed on the bottom of the quartz vessel containing (3ml) of pure ethanol. The influence laser energy on the properties of the formed nano-particles  were characterized by using atomic force microscopy (AFM), X-ray diffraction (XRD), Ultraviolet Visible (UV-Vis) technique, and electrical properties measurements. The XRD revealed the crystallization  structure of  In2O3  nanoparticles and all the films having preferential orientation along (222) plane and intensity increases with increasing laser energy, The UV–Visible spect

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Evaluation of Low Level Laser Therapy using 785 nm Diode Laser on the Enhancement of Chronic Wound Healing
...Show More Authors

Low-intensity laser irradiation has been explored as an alternative, non-invasive method to encourage chronic wounds to heal. This study aimed to evaluate the effects of low level laser therapy (biostimulation) using semiconductor diode laser with wavelength (785 nm) on the enhancement of chronic wound healing. Fifty patients with chronic wounds were selected to be treated with Low Level Laser Therapy. Their ages ranged between 1 to 76 years. The wound sites were distributed in the lower limb, upper limb, trunk , perineum and head (70%,14%,12%,2%,2%, respectively). Application of laser therapy by noncontact method few millimeters from the skin for 15 minutes per one session twice weekly for two months ; ie,16 sessions for each patient. R

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Al-khwarizmi Engineering Journal
Drilling of FR-4 Composite Materials Using Single Pulse of Nd:YAG Laser
...Show More Authors

Laser drilling is capable of producing small, precisely positioned holes with high degree of reproductively. In this paper , IR millisecond Nd:YAG single pulsed laser was used to determine the effect of laser parameters on the drilled hole of the glass - fiber reinforced epoxy composite FR-4 sample of 2 mm in thickness . The type of laser source was GSI lumonics JK760TR Series laser 1.064μm system in a CNC cabin. The JK760TR series has a 0.3-50ms pulse length and a maximum repetition rate 500Hz with an average power of 600W. The investigation of single pulse laser drilling in this paper was based on theoretical and experimental solutions. In single pulse technique, the investigation included focal plane position fpp, pulse shap

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Breast Tumor Diagnosis Using Diode Laser in Near Infrared Region
...Show More Authors

In the last years, new non-invasively laser methods were used to detect breast tumors for pre- and postmenopausal females. The methods based on using laser radiation are safer than the other daily used methods for breast tumor detection like X-ray mammography, CT-scanner, and nuclear medicine.  

      One of these new methods is called FDPM (Frequency Domain Photon Migration). It is based on the modulation of laser beam by variable frequency sinusoidal waves. The modulated laser radiations illuminate the breast tissue and received from opposite side.

      In this paper the amplitude and the phase shift of the received signal were calculated according to the orig

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 08 2023
Journal Name
Journal Of Wasit For Science And Medicine
Study on physical properties of nanostructured ZnO prepared by pulse laser deposition
...Show More Authors

Zinc Oxide thin film of 2 μm thickness has been grown on glass substrate by pulsed laser deposition technique at substrate temperature of 500 oC under the vacuum pressure of 8×10-2 mbar. The optical properties concerning the absorption, and transmission spectra were studied for the prepared thin film. From the transmission spectra, the optical gap and linear refractive index of the ZnO thin film was determined. The structure of the ZnO thin film was tested with X-Ray diffraction and it was formed to be a polycrystalline with many peaks.

View Publication Preview PDF
Crossref
Publication Date
Sat Jun 01 2013
Journal Name
Diyala Journal Of Engineering Sciences
Generation of entangled photons by short coherence length violet diode laser
...Show More Authors

Pumping a BBO crystal by a violet diode laser with a wavelength of (405 nm) output power of (24 mW) and a line width of (3nm) was employed to generate entangled photons with a wavelength of 810 nm by achieving type II phase matching conditions.The coincidence count rate obtained in this experiment was in the range of (18000) counts/s. Two BBO crystals with different thicknesses of (4 mm and 2 mm) were tested, where maximum count rates of about (18000) counts/s was obtained with a (5*5*2) mm BBO crystal where the short coherence time for the pumping source was tolerated by using shorter BBO crystals. Also, the effect of compensating crystal on the walk-off effect was studied. The coincidence count rates were increased by using these crystal

... Show More
View Publication