Single mode-no core-single mode fiber structure with a section of tuned no-core fiber diameter to sense changes in relative humidity has been experimentally demonstrated. The sensor performance with tuned NCF diameter was investigated to maximize the evanescent fields. Different tuned diameters of of (100, 80, and 60)μm were obtained by chemical etching process based on hydrofluoric acid immersion. The highest wavelength sensitivity was obtained 184.57 pm/RH% in the RH range of 30% –100% when the no-core fiber diameter diameter was 60 μm and the sensor response was in real-time measurements
The proposal of this study is demonstrating a simple vapor sensor for chloroform (CHCI3) utilitizing air gap region of the Mach-Zehnder interferometer (MZI) by using a single mode optical fiber coupler (3 dB) structure. In the last few decades, flammable liquids such as chloroform have been highly used. This chemical liquid has some degrees of carcinogenic effects in humans in addition to acute and chronic exposure results like blurred vision and nausea. The two arms of MZI contain a free space gap utilized to serve the sensing mechanism by adding chemical liquid volumes (0.2, 0.4, 0.6, 0.8, and 1) ml and to set the phase difference with air-gap distance 0.5 mm. The small variation in the effective refractive index of ch
... Show MoreFunctionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p
... Show MoreIn this study, tin oxide (SnO2) and mixed with cadmium oxide (CdO) with concentration ratio of (5, 10, 15, 20)% films were deposited by spray pyrolysis technique onto glass substrates at 300ºC temperature. The structure of the SnO2:CdO mixed films have polycrystalline structure with (110) and (101) preferential orientations. Atomic force microscopy (AFM) show the films are displayed granular structure. It was found that the grain size increases with increasing of mixed concentration ratio. The transmittance in visible and NIR region was estimated for SnO2:CdO mixed films. Direct optical band gap was estimated for SnO2 and SnO2 mixed CdO and show a decrease in the energy gap with increasing mixing ratio. From Hall measurement, it was fou
... Show MoreThe main problem when dealing with fuzzy data variables is that it cannot be formed by a model that represents the data through the method of Fuzzy Least Squares Estimator (FLSE) which gives false estimates of the invalidity of the method in the case of the existence of the problem of multicollinearity. To overcome this problem, the Fuzzy Bridge Regression Estimator (FBRE) Method was relied upon to estimate a fuzzy linear regression model by triangular fuzzy numbers. Moreover, the detection of the problem of multicollinearity in the fuzzy data can be done by using Variance Inflation Factor when the inputs variable of the model crisp, output variable, and parameters are fuzzed. The results were compared usin
... Show MoreIn this research, a new application has been developed for games by using the generalization of the separation axioms in topology, in particular regular, Sg-regular and SSg- regular spaces. The games under study consist of two players and the victory of the second player depends on the strategy and choice of the first player. Many regularity, Sg, SSg regularity theorems have been proven using this type of game, and many results and illustrative examples have been presented
Abstract
Objectives: To find out the association between enhancing learning needs and demographic characteristic of (gender, education level and age).
Methods: This study was conducted on purposive sample was selected to obtain representative and accurate data consisting of (90) patients who are in a peroid of recovering from myocardial infarction at Missan Center for Cardiac Diseases and Surgery, (10) patients were excluded for the pilot study, Data were analyzed using descriptive statistical data analysis approach of frequency, percentage, and analysis of variance (ANOVA).
Results: The study finding shows, there was sign
... Show MoreThe current study aims to identify the effect of guided visualization strategy in developing the visual perception among kindergarteners. The experimental design was used; pre-post test. A total of (32) boy and girl ranging 5 to 6 years old were selected from al-Rabeea’ kindergarten, directorate of al-karkh 2 / Baghdad. The sample divided into equal two group (16) boy and girl of each one. al-Talaqany’s (2016) visual perception skills test among kindergarteners was adopted to collect the required data. The collected data had processed based on (gender, pre-post test, and age). To achieve the objectives of the study; the researcher set up series of sessions that addressed the guided visualization strategy among kindergarteners compose
... Show MoreBackground: Lung cancer is the leading cause of cancer deaths and its incidence is rising. The determination of histopathology and stage of primary lung carcinoma is crucial to develop appropriate treatment approach that affects morbidity and mortality. Fiber optic bronchoscope techniques for early detection of lung cancer are a promising tool as they might allow visualizing changes of early lung cancer and also permitting sampling for histological confirmation.
Objective: This study was intended to compare the fiber optic bronchoscopy findings and their anatomical locations with the histopathology types in patients with lung cancer.
Patient and Methods: A cross section study was conducted during the period
The result of a developed mathematical model for predicting the design
parameters of the fiber Raman amplifier (FRA) are demonstrated. The amplification
parameters are tested at different pump power with different fiber length. Recently,
the FRA employed in optical communication system to increase the repeater distance
as will as the capacity of the communication systems. The output results show, that
high Raman gain can be achieved by high pumping power, long effective area that
need to be small for high Raman gain. High-stimulated Raman gain coefficient is
recommended for high Raman amplifier gain, the low attenuation of the pump and the
transmitted signal in the fiber lead to high Raman gain.