Frequency Doubled Nd: YAG Laser for the Treatment of Diabetic Retinopathy
...Show More Authors

The present study was conducted with a view to determine whether focal laser therapy result in visual recovery and regression of macular edema in patients with non proliferative diabetic retinopathy and maculopathy ,and whether combined focal and scatter laser therapy in patients with proliferative diabetic retinopathy and maculopathy results in visual recovery ,regression of macular edema and regression of the risk factors. In the present work, a frequency doubled Nd: YAG laser was used for the treatment of diabetic retinopathy. The study evaluates 41 eyes of 33 diabetic patients both with Insulin Dependent Diabetes Mellitus IDDM, (n=16) and Non Insulin Dependent Diabetes Mellitus NIDDM, (n=17) with diabetic retinopathy divided into two groups. Maculopathy was regressed in 32/41 treated eyes, 23/24 with maculopathy and non-proliferative diabetic retinopathy are treated by grid laser photocoagulation, 9/17 with proliferative diabetic retinopathy and maculopathy are treated by grid combined with pan retinal photocoagulation. Maculopathy was unchanged in 7/41, deterioration in 2/41. Visual acuity improved in 8/41 patients one line of Snellen chart in young patients with shorter duration and non- proliferative diabetic retinopathy, and good visual acuity prior to therapy and 31/41 stabilized visual acuity for the follow up period, 2/41 deterioration of visual acuity by one line of Snellen chart with progression of edema, hemorrhage and exudation, 3/41 patients complain of paracentral scotoma one-week post treatment improved gradually after 2 weeks. Higher power density is needed to treat the diffuse form of maculopathy regarding the severity of maculopathy and macular edema. The power density needed to have the desired effect is less in more pigmented fundus than in fair fundus in order to have the same effect.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Iraqi Journal Of Science
Spectroscopy Diagnostic of Laser Intensity Effect on Zn Plasma Parameters Generated by Nd: YAG Laser
...Show More Authors

      The creation and characterization of laser-generated plasma are affected by laser irradiance, representing significant phenomena in many applications.  The present work studied the spectroscopy diagnostic of laser irradiance effect on Zn plasma features created in the air by a Q-switched Nd: YAG laser at the fundamental wavelength (1064nm).  The major plasma parameters (electron temperature and electron density) have been measured using the Boltzmann plot and the Stark broadening methods.  The value of electrons temperature ranged from 6138–6067 K, and the electron density in the range of 1.4×1018 to 2×1018 cm-3, for laser irradiance range from 2.1 to 4.8×108 (W/cm2

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Cystatin-C marker in diabetic and non diabetic patients with ischemic heart disease
...Show More Authors

Background:recent data indicate the prevalence of cardiovascular disease in patientswith high cystatin-C level;it can be used as a good predictor for assessment of mortality in cardiovascular diseases regardless of the status of renal function.
Patients and methods: Onehundred twenty (120) patients with ischemic heart disease admitted to this study at Baghdad teaching hospital for the period from January 2011 to September2011,Those patients categorized into two groups (60) diabetic and (60) non diabetic in comparison to fifty healthy control.Fasting serum cystatin-C was measured in all patients and controls.
Results: The level of serum cystatin-C, in diabetic patients with ischemic heart disease was (2.05±0.55 μg/L). Its level in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Baghdad Science Journal
Experimental Evidence of Chaotic Resonance in Semiconductor Laser
...Show More Authors

In this paper, an experimental study has been conducted regarding the indication of resonance in chaotic semiconductor laser.  Resonant perturbations are effective for harnessing nonlinear oscillators for various applications such as inducing chaos and controlling chaos. Interesting results have been obtained regarding to the effect of the   chaotic resonance by adding the frequency on the systems. The frequency changes nonlinear dynamical system through a critical value, there is a transition from a periodic attractor to a strange attractor. The amplitude has a very relevant impact on the system, resulting in an optimal resonance response for appropriate values related to correlation time. The chaotic system becomes regular under

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Theoretical Study of the Lasing Output for a Quasi-Three-Level Operation in Nd 3+:YAG Thin- Disk Laser
...Show More Authors

In this research, the effect of each of the concentrations ( Nd+3) was studied (N) the thickness of the thin disk (d) the number of times that the pumping beam passes through the effective medium of this laser (Mp) the reflectivity of the laser output mirror (R 2) The losses of the effective medium (L) and the pumping power used in achieving the reverse qualification (PP) on each of the pumping threshold capacities (Pp.th) and the output power of the laser (Pout) and the efficiency (ŋ) in Nd3+ thin-disk lasers (TDLs) pumping quasi-three-level With continuous operation (cw), at room temperature, and in the Gaussian mode (TEM00),

We found under these opera

... Show More
View Publication
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Simulation Study on Optically Designed Refractive Beam Expander for Nd: YAG Laser Harmonics for 7 Km Detection Range
...Show More Authors

The simulation study has been conducted for the harmonics of Nd: YAG laser, namely the second harmonic generation SHG, the third harmonic generation THG, and the fourth harmonic generation FHG. Determination of beam expander's expansion ratio for specific wavelength and given detection range is the key in beam expander design for determining minimum laser spot size at the target. Knowing optimum expansion ratio decreases receiving unit dimensions and increases its performance efficiency. Simulation of the above mentioned parameters is conducted for the two types of refractive beam expander, Keplerian and Galilean. Ideal refractive indices for the lenses are chosen adequately for Nd: YAG laser harmonics wavelengths, so that increasing transm

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Nd-YAG laser-irradiation on fluoride uptake by tooth enamel surface (In vitro)
...Show More Authors

Background: The irradiation of teeth with a laser results in an interaction between the light and the biological constituents of the dental hard substance, which is converted directly into heat.This thermal effect is the cause of the structural and chemical enamel changes.The combined treatment of topical fluoride agent with laser may increase fluoride uptake, and reduce progression of caries-like lesions. The aim of this study was to measure the uptake of the acidulated phosphate fluoride and sodium fluoride to the buccal and lingual caries-like lesion enamel surfaces before and after irradiated by Nd-YAG laser in comparison with matching control group. Materials and methods: The sample consisted of 30 human healthy upper premolar teeth wh

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 24 2023
Journal Name
Iraqi Journal Of Science
Edge detection for Diabetic Retinopathy using fuzzy logic
...Show More Authors

Diabetic retinopathy is an eye disease, because of pressure in eye nerve fiber. It is a major cause of blindness in middle as well as older age groups; therefore it is essential to diagnose it earlier. Some of the challenges are in the diagnosis of the disease is detection edges of the image, may be some important edges are missed outcome the noise around the corners.
Wherefore, in order to reduce these effects in this paper, we proposed a new technique for edge detection using traditional operators in combination with fuzzy logic based on fuzzy inference system. The results show that the proposed fuzzy edge detection technique better than of traditional techniques, where vascular are markedly detected over the original.

View Publication Preview PDF
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
The Effect of 532nm Nd: YAG Pulsed Laser on the Activity of Superoxide dismutase and Alcoholdehydrogenase of Saccharomyces Cerevisiae
...Show More Authors

In this study, the effect of Nd: YAG laser on the activity of superoxide dismutase (SOD) and alcoholdehydrogenase (ADH) was investigated. The Saccharomyces cells were irradiated using 532nm Q-Switched Nd: YAG laser with (1Hz) frequency. Different fluences 11.3, 22.6 and 33.9mJ/cm2 and different number of pulses 15, 30 and 60 pulse were used. The irradiated cells were incubated in a liquid nutritive medium for 24 hours. After incubation, the cells were harvested and disrupted to extract the intracellular enzymes and their activities were assessed. In comparison with the control, the irradiated cells showed a significant increase in the activity and the specific activity of SOD at energy densities of 11.3 and 22.6mJ/cm2 at 30 and 60 pulses

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
Effect of Nd-YAG, XeCl, and Nitrogen Laser Radiation on Human Aorta , and Some Arterial Tissues
...Show More Authors

The effect of laser radiation on human aorta, coronary, and pulmonary arteries, and pulmonary veins has been investigated. Xenon-Chloride (eximer), Nitrogen, and Nd-YAG pulsed lasers of wavelengths 308, 337, and 1060 nm respectively were used. Their effects on fresh postmortem tissues, normal and diseased, was studied. The diameter and depth of ablation of the exposed tissues, in air, were measured as a function of many factors related to the type of laser and nature of the tissue. The effect of properties of the applied lasers, such as average power density and deposited energy density, on the exposed tissue surface were studied. The increase of these two parameters cause an increase in the depth and diameter of ablation. However the di

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
The Use of Pulse Frequency Modulation Technique for Optical Video Communication System
...Show More Authors

An optical video communication system is designed and constructed using pulse frequency modulation (PFM) technique. In this work PFM pulses are generated at the transmitter using voltage control oscillator (VCO) of width 50 ns for each pulse. Double frequency, equal width and narrow pulses are produced in the receiver be for demodulation. The use of the frequency doubling technique in such a system results in a narrow transmission bandwidth (25 ns) and high receiver sensitivity.