Preferred Language
Articles
/
ijl-159
Microdrop Size Measurement in a Mixing Unit Using Laser Technique
...Show More Authors

One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by laser light according to the scattering (attenuation) of the laser beam during passing through the emulsion. The same droplet which where examined by the laser beam, where tested also under microphotography system. The result showed that the laser detection technique gives drop diameter smaller than that obtained by photographing.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Human Skin WoundWelding Using 980 nm Diode Laser: an in Vitro Experimental Study
...Show More Authors

Laser assisted skin wound closure offers many distinct advantages over conventional closure
techniques. The objective of this in vitro experimental study, carried out at the Institute of Laser for
Postgraduate Studies/Baghdad University, was to determine the effectiveness of 980 nm diode laser in
welding of human skin wounds. Multiple 3-4 cm long full thickness incisions in a specimen of human
skin obtained from the discarded panniculus of an Abdominoplasty operation were tried to be laser
welded using a 4 mm spot diameter laser beam from a 980 nm diode laser at different laser parameters
and modes of action. The tensile strength at the weld site was analyzed experimentally. Although laser
assisted wound welding did

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Theoretical Computation of Electron Density in Laser-Induced Carbon Plasma using Anisimov Model
...Show More Authors

In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance

... Show More
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Urinary Tract Stones Fragmentation using (2100 nm) Holmium: YAG Laser: (In vitro Analysis)
...Show More Authors

Urinary stones are one of the most common painful disorders of the urinary system. Four new technologies have transformed the treatment of urinary stones: Electrohydraulic lithotripsy, ultrasonic lithotripsy, extracorporeal shock wave lithotripsy, and laser lithotripsy.The purpose of this study is to determine whether pulsed holmium laser energy is an effective method for fragmenting urinary tract stones in vitro, and to determine whether stone composition affects the efficacy of holmium laser lithotripsy. Human urinary stones of known composition with different sizes, shapes and colors were used for this study. The weight and the size of each stone were measured. The surgical laser system which used in our study is Ho:YAG laser(2100nm)

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Theoretical Computation of Electron Density in Laser-Induced Carbon Plasma using Anisimov Model
...Show More Authors

In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 31 2021
Journal Name
Iraqi Journal Of Science
Impact of Laser Energy on Features of Carbon Nanostructure Materials Prepared by A One-Step Pulsed Laser Ablation in Water
...Show More Authors

     Carbon nanoparticles (CNPs) formed by one-step laser ablation in deionized water were carefully studied. Scanning electron microscopy, atomic force microscopy, Raman spectroscopy, and UV–V spectroscopy were used to obtain morphological, chemical, and optical properties of CNPs. SEM outcomes established that the synthesized nanoparticles are semi-spherical with a wide particle size distribution. Raman investigation showed two typical and expected peaks ~ (1300 - 2700) cm−1, which are confirming to transverse and longitudinal modes of the carbon structure. The absorption spectra proved that the intensity of spectra increases as particle size and concentration increase.

View Publication Preview PDF
Scopus (9)
Crossref (7)
Scopus Crossref
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Subclinical Hypothyroidism in Obese Iraqi Patients Attending Obesity Research and Therapy Unit
...Show More Authors

ABSTRACTBackground Subclinical hypothyroidism is mild thyroid hormone deficiency, defined by elevation of serum thyroid-stimulating hormone concentration despite a normal free T3, free T4 level, can be distinguished by clinical and circumstantial observations from other conditions that cause this constellation of laboratory findings. The aim is to find the prevalence, anthropologic, and metabolic changes associate subclinical hypothyroidism(SH) in adult patients presented to obesity research and therapy unit (ORTU Objective: To find the prevalence of subclinical hypothyroidism (SH) in adult obese patients presented to obesity research and therapy unit (ORTU) in AL-Kindy College of medicine and to describe the anthropologic and metabolic

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 30 2022
Journal Name
Iraqi Journal Of Science
Measurement of Absorbed Dose in Water Using Co-60 gamma source Teletherapy Units According to IAEA Dosimetry Protocols
...Show More Authors

      Modern radiotherapy facilities like 3-Dimensional conformal radio therapy (3DCRT), Intensity Modulated Radiotherapy (IMRT), were recently suggested in Co-60 machine with Multi-leaf Collimator (MLC). In this study, two reference chambers NE-2571#1205 and NE2581#537 were used for absolute dose measurement in Equinox accelerator. A comparison of dose measurement by two different IAEA protocols TRS-277 and TRS-398 has been studied. Analyzing TRS-398, a common shaped empirical formula was developed for the four Co-60 units of four Medical Colleges in Bangladesh with fitting parameters. It was found that an average discrepancy in the determination of absorbed dose in water among the two different protocols TRS-277 and TRS-398 were 1

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Measurement of Indoor Radon Gas Concentration in same Region of Baghdad Governorate Using CR-39 Nuclear Track Detector
...Show More Authors

In this research the activity of radon gas in air in Baghad governorate,Iraq, using “alpha-emitters track registration (CR-39) track detector were measured. This measurement was done for selected areas from Baghdad Governorate, The results obtained shows that the highest average concentrations for Rn-222 is (179.077 Bq/m^3) which was recorded within Al-Shaaib city and less average concentrations was (15.79 Bq/m^3) in the nearby residential area of Baghdad International Airport and the overall average concentrations is (86.508 Bq/m^3) for these regions. Then the radon concentration was measured annual effective dose calculated from radon concentration and found in range from 0.4031 mSv/y to 4.5179 mSv /y with an average value of 2.1824 m

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Mon Apr 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Measurement of The Specific Activity For Beryllium-7 Isotope in Soil of Baghdad City Using Gamma Ray Spectrometry
...Show More Authors

  This study deals with the measurement of the specific activity radiation for beryllium -7 isotope in Baghdad city for samples of surface soils, by using gamma ray spectrometer technique.       Twenty one samples were collected from surface soil of Baghdad city from Risafa and Karkh sides, (7) samples from  Risafa side and(14) samples from Karkh side, where the axis for locations which are fixed by using (G.P.S.) .  Gamma-ray spectrometry system (DSA 2000) with high purity germanium detector was used, which has (50%) efficiency and resolution of (2.2 keV) at gamma line (1332 keV) of 60Co source.        The specific activity values for beryllium -7  isotope in surface soil of  R

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 27 2022
Journal Name
Iraqi Journal Of Science
Measurement and Analysis of the Distribution of Pb-214 Lead Isotope in Baghdad Soil using Remote Sensing Techniques
...Show More Authors

     The present research aims to measure concentration of lead  Pb214 in soil using remote sensing and GIS, associated radiological hazards in Baghdad, Iraq. Concentration of specific radioactivity of radioactive elements was measured and analyzed naturally and artificially in 48 soil samples for separate sites from Baghdad, Iraq using crystalline spectroscopy to detect germanium. The average radioactivity concentrations of lead were found, as it was found to have varying values ​​from one site to another, as most of them exceeded the international permissible limit, as the highest concentration was recorded at 180 Bq in the sample H28 in Waziriyah district. Battery Lab (1), and the lowest concentration valu

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Crossref