One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by laser light according to the scattering (attenuation) of the laser beam during passing through the emulsion. The same droplet which where examined by the laser beam, where tested also under microphotography system. The result showed that the laser detection technique gives drop diameter smaller than that obtained by photographing.
Abstract: Under high-excitation irradiance conditions to induce fluorescence, the dependence of photobleaching of Coumarin 307 (C307) and acriflavine (ACF) laser dyes in liquid and solid phases have been studied. A cw LD laser source of 1 mW and 407 nm wavelength was used as an exciting source. For one hour exposure time, it was found that the solid dye samples suffer photobleaching more than the liquid dye samples. This is because in liquid solutions the dye molecules can circulate during the irradiation, while the photobleaching is a serious problem when the dye is incorporated into solid matrix and cannot circulate.
A high power N2 laser of the three stage-Blumlein circuit designed, which consist two identical electrodes, four capacitors and three spark gaps which designed discharge geometry with minimum inductance. This system gives a maximum energy 18 mJ with a pulse time 6.65 ns and wave length 337.1 nm. The distance between spark gap terminals has large effect on the output energy. The ideal distance were 11 mm between the terminals for the first spark gap and 4 mm between the terminals for the second spark gap, the distance between the terminals of the spark gaps has a significant effect on the resulting energy, where the energy decreases when the distance between the terminals of the first and second s
... Show MoreMany researches focused on laser therapy of wound healing in different animal models due to the lack of a standard protocol in the application of such phototherapy. Objective: To study the effects of 810nm laser at a constant irradiance of 41.63 mw/cm2 and exposure (illumination) time of 5,15 minutes on wounds created on Albino mice (BALB/c).
Skin wound with elliptic shape and full thickness was created on the dorsal side of ‘45 mature male albino mice. Irradiated animals were divided into two main groups based on irradiation time, the first was irradiated for 5 min and the second for 15 min, each was subdivided into three subgroups (n=5) according to number of treatment
... Show MoreIn this study, ultraviolet (UV), ozone techniques with hydrogen peroxide oxidant were used to treat the wastewater which is produced from South Baghdad Power Station using lab-scale system. From UV-H2O2 experiments, it was shown that the optimum exposure time was 80 min. At this time, the highest removal percentages of oil, COD, and TOC were 84.69 %, 56.33 % and 50 % respectively. Effect of pH on the contaminants removing was studied in the range of (2-12). The best oil, COD, and TOC removal percentages (69.38 %, 70 % and 52 %) using H2O2/UV were at pH=12. H2O2/ozone experiments exhibited better performance compared to
... Show MoreTwenty nine core samples were taken from Ratawi 7 Oil well according to the presence of oil in formation and availability of core samples. This well is located in the province of Basra/southern Iraq. The samples were collected from Yamama Formation. The core samples are taken from the well at different depths, ranging between (3663m-3676m). The range of Vp for these core samples is (668-4017 m/sec) and its average is (1779 m/sec), While the range of Vs is (291-1854 m/sec) and its average is (796 m/sec). In the current study the ultrasonic method is conducted to measure Vp, Vs as well as some petrophysical properties for core samples and some elastic moduli such as (Young's modulus, Bulk modulus, Shear modulus, Poisson's ratio and Lame's
... Show MoreNonlinear diffraction pattern can be induced by focusing CW
laser into a thin quartzes cuvette containing nanofluid. The number
of revealed pattern rings indicates to the nonlinear behavior of fluid.
Here, the nonlinear refractive index of each of functionalized single
wall carbon nanotube (F-SWCNTs) suspention and multi wall carbon
nanotube (F-MWCNTs) suspention have been investigated
experimentally .Each of CNTs suspention was at volume fraction of
13×10−5 and 6×10−5. Moreover the laser source at wavelength of
473 nm was used. The results show that SWCNTs suspention
possesses higher nonlinearty than other at the same volume fraction
The variation in wing morphological features was investigated using geometric morphometric technique of the Sand Fly from two Iraqi provinces Babylon and Diyala . We distributed eleven landmarks on the wings of Sand Fly species. By using the centroid size and shape together, all species were clearly distinguished. It is clear from these results that the wing analysis is an essential method for future geometric morphometry studies to distinguish the species of Sand Flies in Iraq.
The proposed method is sensitive, simple , fast for the determination of mebeverine hydrochloride in pure form or in pharmaceutical dosage . Using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. Where it is based upon the fluorescence of fluorescein sodium salt and quenching effect of fluorescence by mebeverine in aqueous medium. The calibration graph was linear in the concentration range 0.05 to10 mMol.L-1 (r= 0.9629) with relative standard deviation (RSD%) for 1 mMol.L-1mebeverine solution was lower than 3% (n=6). Three pharmaceutical drugs were used as an application for the determination of mebeverine. A comparison was made between the newly developed method of analysis wit
... Show MoreThe objective of this study was to establish an accurate, precise, sensitive, simple, fast and reliable method for the determination of ciprofloxacin hydrochloride in pure or in pharmaceutical dosage forms using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. The method is based upon the fluorescence fluorescein sodium salt and its quenching by ciprofloxacin hydrochloride in aqueous medium. The solutions of standard and the sample were prepared in distilled water. The calibration graph was linear in the concentration range of using (10 - 100) mMol.L-1 ciprofloxacin hydrochloride (r= 0.9891) with relative standard deviation (RSD%) for 3 mMol.L-1 ciprofloxacin HCl solution is
... Show MoreThe interest in pre-service teacher training has become influential in teaching English as a foreign language, and the purpose of this training course is to prepare qualified teachers to teach effectively through the application of this technique by undergraduate students. This research aims to find out the effect of using the seven principles of good practice as a teaching technique on the fourth stage student-teachers’ performance at the College of Education for Women/University of Baghdad, during the academic year 2017-2018. The sample includes (60) students selected according to the stratified sampling method. The observational checklist used by the department to assess the student teachers’ performance during the practicum perio
... Show More