Preferred Language
Articles
/
ijl-157
Interstitial Photocoagulation of Low Anal Fistula using 810 nm Diode Laser: Prospective Study
...Show More Authors

Many conservative sphincter-preserving procedures had been described to be effective in
healing of anal fistula without excision or de roofing.
Objective: To verify the outcome of mere photocoagulation of the fistula tract on healing of low anal
fistula.
Materials and Methods: Using 810nm diode laser, the tracts of low anal fistulae in a cohorts of six male
patients (mean age of 32 yr) had been photocoagulated by retrograde application of laser light through an
orb tip optical fiber threaded in to the tract. Swabs for culture and sensitivity testing were obtained before
and after laser application. Patients were followed up regularly to announce fistula healing.
Results: Mean laser exposure time was 6.6 min., mean operative time was 19 min., mean hospital stay
was 5.9 hrs and mean fistula closure time was 7.7 days. The negative immediate post laser exposure
swabs indicate that laser may have a bacteria killing power. There were no evidences of incontinence or
recurrence within the mean follow up period of 9 weeks. The feasibility of using the selected laser and
accessory was excellent. The basic laser-tissue interaction was thermal photocoagulation without
carbonization.
Conclusions and Recommendations: Mere photocoagulation of the fistula tract may heal a low anal
fistula. Within the chosen parameters of laser application, there was no evidence of damage to the anal
sphincter. It is recommended that larger number of cases to be done to allow for proper statistical
analysis. High, complicated, and recurrent cases may be included. A longer follow up period to assess
intermediate and long term recurrences is recommended.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF
Publication Date
Tue Aug 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Post a reflection on the capabilities of personnel programs A prospective study of a sample of the views of the staff at the Ministry of Higher Education and Scientific Research
...Show More Authors

            This research aims to know the role and impact of participation in the capabilities of human resources programs, and for the purpose of measuring it has been determined the dimensions of these two variables by relying on standards for this purpose, was chosen as the Ministry of Higher Education and Scientific Research / device supervision and scientific calendar as one of the important departments in the ministry and includes a large number of individuals at different organizational levels for the purpose of answering a questionnaire prepared for the purpose of measurement and access to the results and the achievement of the objectives of the research and which ha

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
A Study Of Corrosion Inhibition Of Low Carbon Steel In Washing Water Of Crude Oil Solution In The Presence Of Folic Acid
...Show More Authors

The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range (30–70)°C .The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature. Folic acid had on inhibiting effect on the corrosion of low carbon steel in washing water at a concentration (5× 10-4-- 5× 10-3 ) mol/dm3 over the temperature range (30–70)°C. Values of the protection efficiency were calculated from the corrosion current density .From the general results for this study, it can be seen that thermodynamic and kinetic function were also calculated (?G, ?S, ?H and Ea )

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Apr 01 2019
Journal Name
The Saudi Dental Journal
Implementation and characterization of coating pure titanium dental implant with sintered β-TCP by using Nd:YAG laser
...Show More Authors

Objectives This work presents laser coating of grade 1 pure titanium (Ti) dental implant surface with sintered biological apatite beta-tricalcium phosphate (β-TCP), which has a chemical composition close to bone. Materials and methods Pulsed Nd:YAG laser of single pulse capability up to 70 J/10 ms and pulse peak power of 8 kW was used to implement the task. Laser pulse peak power, pulse duration, repetition rate and scanning speed were modulated to achieve the most homogenous, cohesive and highly adherent coat layer. Scanning electron microscopy (SEM), energy dispersive X-ray microscopy (EDX), optical microscopy and nanoindentation analyses were conducted to characterise and evaluate the microstructure, phases, modulus of elasticity

... Show More
View Publication
Scopus (25)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Physics: Conference Series
Studying the effect of changing optical fibers parameters on their modes properties at 1000 nm wavelength
...Show More Authors
Abstract<p>Optical fiber technology is without a doubt one of the most significant phases of the communications revolution and is crucial to our daily lives. Using the free version (2022) of RP Fiber Calculator, the modal properties for optical fibers with core radii (1.5−7.5) μm, core index (1.44−1.48) and cladding index (1.43−1.47) have been determined at a wavelength of 1000 nm. When the fiber core’s radius is larger than its operating wavelength, multimode fibers can be created. The result is a single-mode fiber in all other cases. All of the calculated properties, it has been shown, increase with increasing core radius. The modes’ intensity profiles were displayed.</p>
View Publication
Scopus Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of Physics: Conference Series
Studying the properties of linearly polarized modes in step index optical fibers at 1030 nm wavelength
...Show More Authors
Abstract<p>The growing demand for optical fibers is due to their superior the ability to transmit information with high efficiency and minimal loss across extensive distances. In this study, four optical fibers with core radii ranging from (2.05-5.05) μm, and with a numerical aperture of 0.1624 were analyzed. The modal properties of these fibers were calculated at a wavelength of 1030 nm using the RP Fiber Calculator software (free version 2025). Furthermore, the impact of increasing the core radius on these properties was examined. The results showed that multimode fibers are formed when the core radius is much larger than the wavelength used. In contrast, single-mode fiber is obtained when th</p> ... Show More
View Publication
Crossref
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
A Study Of Corrosion Behavior Of Low Carbon Steel In Acidic And Basic Washing Water Of Crude Oil Solution At Different Temperatures
...Show More Authors

The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Bactericidal Effect of CO2 Laser on Bacteria Associated With Dental Implant Infection: An In Vitro Study
...Show More Authors

One of the most popular causes for implant infection is dental plaque bacteria. Previous studies have shown the bactericidal effect of CO2 laser irradiation on bacteria associated with soft tissue surrounding the implant materials. No published studies have examined the effect of irradiation by CO2 laser on Streptococcus oralis and Staphylococcus aureus.The aim of this study was to evaluate the bactericidal effect of CO2 laser on bacteria that are causing dental implant infections. This study was carried out on two isolates of bacterial species out of 25 samples, isolated from patients having soft tissue infections around the dental implant. These two pure isolates including Streptococcus oralis and Staphylococcus aureus were identified

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2021
Journal Name
Journal Of Physics: Conference Series
Pretreated Fishbone as Low Cost-Adsorbent for Cationic Dye Adsorption from Aqueous Solutions: Equilibrium, Optimization, Kinetic and Thermodynamic Study
...Show More Authors

The present study investigated the use of pretreated fish bone (PTFB) as a new surface, natural waste and low-cost adsorbent for the adsorption of Methyl green (MG, as model toxic basic dye) from aqueous solutions. The functional groups and surface morphology of the untreated fish bone (FB) and pretreated fish bone were characterized using Fourier transform infrared (FTIR), scanning electron microscopy (SEM) and Energy dispersive X-ray spectroscopy (EDS),respectively. The effect of operating parameters including contact time, pH, adsorbent dose, temperature, and inorganic salt was evaluated. Langmuir, Freundlich and Temkin adsorption isotherm models were studied and the results showed that the adsorption of basic dye followed Freundlich iso

... Show More
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Pretreated Fishbone as Low Cost-Adsorbent for Cationic Dye Adsorption from Aqueous Solutions: Equilibrium, Optimization, Kinetic and Thermodynamic Study
...Show More Authors
Abstract<p>The present study investigated the use of pretreated fish bone (PTFB) as a new surface, natural waste and low-cost adsorbent for the adsorption of Methyl green (MG, as model toxic basic dye) from aqueous solutions. The functional groups and surface morphology of the untreated fish bone (FB) and pretreated fish bone were characterized using Fourier transform infrared (FTIR), scanning electron microscopy (SEM) and Energy dispersive X-ray spectroscopy (EDS), respectively. The effect of operating parameters including contact time, pH, adsorbent dose, temperature, and inorganic salt was evaluated. Langmuir, Freundlich and Temkin adsorption isotherm models were studied and the results showe</p> ... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Crossref