Breast mass is by far the most important clinical problem that concerns the breast today. This study was carried out to evaluate diode laser as a cutting tool in breast mass excision and as a hemostatic tool for coagulation during surgery. Using 810 nm diode laser with optical fiber 600μm in diameter of conical tip, udder (cow's breast) tissue, and three female patients (mean age of 35.5 y with clinically palpable breast mass) had been used in this study. The patients were followed up regularly postoperatively. In preliminary work on udder tissue, the power needed for cutting and excision was 15W (power density= 5.3 kW/cm2). The time consumed for excision of a piece of udder tissue, 40×10×3 mm in dimensions was 5 min. The depth range of cutting was 2-3 mm. The speed of cutting was 0.6 cm/s. In the clinical work, the power needed for excision was 15 W (5.3 kW/cm2 power density). Power used for coagulation was ranging between 10-15W depending on diameter of blood vessel, the overall blood loss during surgery and postoperatively appeared to be less than that in conventional method. The contact laser scalpel produced clear appearance of surgical margin and saved dissection. Hemostatic capability assured clear anatomical visualization and few ligatures. No clinical evidence of infection at the wound site postoperatively. The results showed that the diode laser is effective in minimizing the intra-operative blood loss, postoperative blood loss, and effective in reducing the postoperative pain, swelling and edema. On follow up the patients were presented with relatively better healing progress, no wound infections, and no need for strong pain killer postoperatively.
Aim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a
... Show MoreA characteristic study of a passively Q-switched diode pumped solid state laser system is presented in this work. For laser a comparison study for the theoretically calculated results with a simulation results using a software which calculates the Q-switched solid state laser parameters was such as energy, peak power and pulse width were performed. There was a good agreement between our theoretical calculations and the simulation values.
Due to the scientific and technical development in the free electron laser devices and the accompanying industrial and technological progress in various fields of civil and military life, it became necessary to expand the understanding of the mechanism of interaction of electrons (as an effective medium) with the magnetic field that they pass through to form coherent photons.
In this paper, the Lorentz force effect is simulated and analysed. The results showed that the Lorentz force originates from the magnetic field, making the electron move through it oscillate. This sinusoidal motion of the electron causes it to emit two photons for every electron wavelength. It has been concluded that the electron velocity directly affe
... Show MoreThe present work aims to evaluate the content of some toxic metals in chemical and organic fertilizers purchased from local markets in Baghdad, Iraq. The analysis was performed by laser-induced breakdown spectroscopy (LIBS) system. The emission spectral lines of lead (Pb), chromium (Cr), cadmium (Cd) and cobalt (Co) have been recorded to determine the best peak representing each element according to the NIST database. The validity of the LIBS procedure was checked by cross-validating the obtained results using atomic absorption spectroscopy (AAS) with a maximum relative error of 5.3%. Moreover, for qualitative analysis, Pb I 296.64 nm emission line was determined to be superior for the evaluation of lead content in terms of three
... Show MoreThis study presents the effect of laser energy on burning loss of magnesium from the holes' drilled in aluminum alloy 5052. High energy free running pulsed Nd:Glass laser of 300 µs pulse duration has been used to perform the experiments. The laser energy was varied from 1.0 to 8.0 Joules, The drilling processes have been carried out under atmospheric pressure and vacuum inside a specially designed chamber. Microhardness of the blind drilled holes has been investigated .The results indicated that the magnesium loss could be manipulated by adjusting the focusing conditions of the laser beam. Almost, the obtained holes were free of cracks with low taper and low sputter deposition. .The holes performed under atmospheric conditions have high
... Show MoreObjective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an
... Show MoreIn this work, different soil samples were brought to study and analyse the element concentrations from different middle regions of Iraq (such as, Habbaniah, Garmah, Fallujah, and Tarmiah cities). Using laser-induced breakdown spectroscopy (LIBS) has been documented as an atomic emission spectroscopy (AES) technique. Laser-induced plasma utilized to analyse elements in materials (gases, liquids, and solids) in order to analyse elements in materials (gases, liquids and solid). The Nd:YAG laser excitation source at 1064nm with pulse width and pulse duration of 9ns is used to generate power density of 5.5 x 1012 MW/mm2, with optical spectrum in the range 320 -740 nm.
The soils of Habbaniyah and Garmah citi
... Show MoreBack ground: Cancer is the second leading cause of death throughout the world. Breast cancer, is one of the leading mortality reasons in women from Western Countries, in Iraq, breast cancer is the second reason of death After cardiovascular Diseases.
Material and method:
The study was carried out of period from October/2016-january /2017 and included (90) serum samples for Iraqi women suffered from breast cancer . Samples were divided into two groups ,the first group included (66) patients (females) their age rang (22-55) years which attended to (tumor unit) at medical city educational oncology hospital and Al-Amal Al-Waatanii hospital in Baghdad ,the second group included (38) for
... Show MoreAbstract
In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3 have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r
... Show More