The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks observed do not result from a single
fluorescent urinary metabolite, but depend on differences in urine component that is changed
according the clinical situation of person
Abstract: This study aims to investigate the effects of solvents of various polarities on the electronic absorption and fluorescence spectra of RhB and Rh6G. The singlet‐state excited dipole moments (me) and ground state dipole moments (mg) were estimated from the equations of Bakshiev -Kawski and Chamma‐ Viallet using the variation of Stokes shift along with the solvent’s dielectric constant (e) and refractive indexes (n). The observed singlet‐state excited dipole moments were found to be larger than the ground‐state ones. Moreover, the obtained fluorescence quantum yield values were influenced by the environment of the fluorescing molecule. Consequently, the concentration of the dye solution, excited singlet state absorption and
... Show MoreMetal enhanced fluorescence (MEF) is an unequaled phenomenon of metal nanoparticle surface plasmons, when light interacts with the metal nanostructures (silver nanoparticles) which result electromagnetic fields to promote the sensitivity of fluorescence. This work endeavor to study the influence of silver nanoparticles on fluorescence intensity of Fluoreseina dye by employment mixture solution with different mixing ratio. Silver nanoparticles had been manufactured by the chemical reduction method so that Ag NP layer coating had been done by hot rotation liquid method. The optical properties of the prepared samples (mixture solution of Fluoreseina dye solutions and colloidal solution with 5 minutes prepared of Ag NPs) tested by using UV-V
... Show MoreUrine proteomics have been an area of interest and recently in Kala-azar as an alternative sample type for serum or plasma. Because of simplicity, noninvasiveness of collection and simpler matrix. Many studies had detected an increased protein excretion in the urine of patients with active Kala-azar due to renal involvement particularly by an immunological related mechanism(s). This study have demonstrated the presence of three different protein profiles in Iraqi children (Patients: including 60 children aged 4-60 months) with defined Kala-azar using the conventional SDS-PAGE on urine samples. Urine protein profile in Kala-azar patients revealed three groups of banding patterns: group-1(33.4)% of the patients show the pattern of 5
... Show MoreThe temperature influence on the fluorescence lifetime, quantum yields and non-radiative rate parameter or coumarin 460 dye dissolved in methanol was investigated in the temperature range (160-300 k). A single photon counting technique was used or measuring the fluorescence decay curves. A noticeable decrease of the fluorescence lifetime with increasing the temperature was observed. The non-radiative activation energy of 10.57 K.J. mole-1 was measured by the help of Arrhenius plot.
Scientific development has occupied a prominent place in the field of diagnosis, far from traditional procedures. Scientific progress and the development of cities have imposed diseases that have spread due to this development, perhaps the most prominent of which is diabetes for accurate diagnosis without examining blood samples and using image analysis by comparing two images of the affected person for no less than a period. Less than ten years ago they used artificial intelligence programs to analyze and prove the validity of this study by collecting samples of infected people and healthy people using one of the Python program libraries, which is (Open-CV) specialized in measuring changes to the human face, through which we can infer the
... Show MoreBrucellosis is possess a significant public health problem in Baghdad. In this study, we investigated the potential role of the PCR assay in detection of Brucella species, from patients suspect to have brucellosis, using blood samples in both human and animal. To establish a PCR technique for diagnosis of active brucellosis in our samples, DNA extraction was carried out using a commercial kit, and a laboratory extraction procedure. PCR amplification was done using 1 set of primers: B4/B5 for Brucella species. Extraction of Brucella DNA using the commercial kit was successful. The laboratory extraction was successful and more economic. A total of 178 peripheral blood
... Show MoreThe search is contain compared among some order selection criteria (FPE,AIC,SBC,H-Q) for the Model first order Autoregressive when the White Noise is follow Normal distribution and some of non Gaussian distributions (Log normal, Exponential and Poisson distribution ) by using Simulation