The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks observed do not result from a single
fluorescent urinary metabolite, but depend on differences in urine component that is changed
according the clinical situation of person
Background: Menstrual problems with all manifestations ranging from life-threatening bleeding to amen- orrhea are considered patterns of abnormal uterine bleeding (AUB), which is until now a popular reason for referral to the gynaecologic clinic and requires a special diagnostic tool. Objective: To assess the accuracy of hysteroscopy in diagnosing endometrial pathologies and to compare it with sonographic and histopathologic reports. Patients and Methods: A prospective study conducted in the Baghdad Teaching Hospital on 60 Iraqi females having varying complaints from abnormal uterine bleeding in pre- and post-menopausal women, infertility, and chronic pelvic pain with normal or abnormal ultrasound findings. Office hysteroscopy was done and
... Show MoreBackground: Breast cancer is the most frequently diagnosed malignancy and the second leading cause of mortality among women in Iraq forming 23% of cancer related deaths. The low survival from the disease is a direct consequence to the advanced stages at diagnoses. Aim: To document the composite stage of breast cancer among Iraqi patients at the time of diagnosis; correlating the observed findings with other clinical and pathological parameters at presentation. Patients and Methods: A retrospective study enrolling the clinical and pathological characteristics of 603 Iraqi female patients diagnosed with breast cancer. The composite stage of breast cancer was determined according to UICC TNM Classification System of Breast Cancer and the Ameri
... Show MoreIn this study, gamma-ray spectrometry with an HPGe detector was used to measure the specific activity concentrations of 226Ra, 232Th, and 40K in soil samples collected from IT1 oil reservoirs in Kirkuk city, northeast Iraq. The “spectral line Gp” gamma analysis software package was used to analyze the spectral data. 226Ra specific activity varies from 9 0.34 Bq.kg-1 to 17 0.47 Bq.kg-1. 232Th specific activity varies from 6.2 0.08 Bq.kg-1 to 18 0.2 Bq.kg-1. 40K specific activity varies from 25 0.19 Bq.kg-1 to 118 0.41 Bq.kg-1. The radiological hazard due to the radiation emitted from natural r
... Show MoreThis study aims at identifying the reality of alternative assessment for teachers of the first cycle of the basic education in the Sultanate of Oman with respect to the degree of teachers' use of alternative assessment strategies, level of self-efficacy for alternative assessment strategies, and attitude towards alternative assessment, and their relationship with other variables. To achieve the aims of the study, a descriptive research approach was utilized. A 5-point self-rated questionnaire was developed. It consists of three sections: Actual use of alternative assessment strategies (21 items), self-efficacy for alternative assessment strategies (21 items), and attitude towards alternative assessment (27 items). The psychometric proper
... Show MoreINTRODUCTION: A range of tools and technologies are at disposal for the purpose of defect detection. These include but are not limited to sensors, Statistical Process Control (SPC) software, Artificial Intelligence (AI) and machine learning (ML) algorithms, X-ray systems, ultrasound systems, and eddy current systems. OBJECTIVES: The determination of the suitable instrument or combination of instruments is contingent upon the precise production procedure and the category of flaw being identified. In certain cases, defects may necessitate real-time monitoring and analysis through the use of sensors and SPC software, whereas more comprehensive analysis may be required for other defects through the utilization of X-ray or ultrasound sy
... Show MoreSubmerged arc welding (SAW) process is an essential metal joining processes in industry. The quality of weld is a very important working aspect for the manufacturing and construction industries, the challenges are made optimal process environment. Design of experimental using Taguchi method (L9 orthogonal array (OA)) considering three SAW parameter are (welding current, arc voltage and welding speed) and three levels (300-350-400 Amp. , 32-36-40 V and 26-28-30 cm/min). The study was done on SAW process parameters on the mechanical properties of steel type comply with (ASTM A516 grade 70). Signal to Noise ratio (S/N) was computed to calculate the optimal process parameters. Percentage contributions of each parameter are validated by using an
... Show MoreThis work aims to optimize surface roughness, wall angle deviation, and average wall thickness as output responses of ALuminium-1050 alloy cone formed by the single point incremental sheet metal forming process. The experiments are accomplished based on the use of a mixed level Taguchi experimental design with an L18 orthogonal array. Six levels of step depth, three levels of tool diameter, feed rate, and tool rotational speed have been considered as input process parameters. The analyses of variance (ANOVA) have been used to investigate the significance of parameters and the effect of their levels for minimum surface roughness, minimum wall angle deviation, and maximum average wall thickness. The results indicate that step depth and tool r
... Show MoreOne of the most important problems in concrete production in Iraq and other country is the high sulfate content in sand that led to damage of concrete and hence reduces its compressive strength and may leads to cracking due to internal sulfate attack and delay ettringite formation. The magnetic water treatment process is adopted in this study. Many samples with different SO3 content are treated with magnetic water (12, 8, 4 and 2)L that needed for each 1kg of sand with the magnetic intensity (9000 and 5000) Gaus. The magnetic water needed is reduced with less SO3 content in sand. The ACI 211.1-91 concrete mix design was used in this research with slump range (75- 100) mm and the specified compressive strength (35MPa). The compressive streng
... Show More