Preferred Language
Articles
/
ijcpe-983
The Effects of Operating Variables on Efficancy of Water Disinfection by Sodium Hypochlorite Using Al-Wathba Wastewater
...Show More Authors

The aim of this investigation was to study the impact of various reaction parameters on wastewater taken from Al-Wathba water treatment plant on Tigris River in south of Baghdad, Iraq with sodium hypochlorite solution. The parameters studied were sodium hypochlorite dose, contact time, initial fecal coliform bacteria concentration, temperature, and pH. In a batch reactor, different concentrations of sodium hypochlorite solution were used to disinfect 1L of water. The amount of hypochlorite ions in disinfected water was measured using an Iodimetry test for different reaction times, whereas the Most Probable Number (MPN) test was used to determine the concentration of coliform bacteria. Total Plate Count (TPC) was utilized in this study to count the number of colonies of common bacteria. Reaction variables that were examined showed that the increase in temperature, pH, and reaction time caused the concentration of Coliform bacteria to decrease, which in turn caused an accumulation-related increase in OCl- concentration. The optimum values of temperature and reaction pH were determined to be 8 and 29o C respectively. The kinetics of the reaction was examined in this study, and the results showed that Selleck model's order of reaction is two, with rate constants of 1.3791x10-5, 3.0806x10-5, and 5.738x10-5 L/(mole min) at 20o, 29o, and 37o C, respectively.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 17 2021
Journal Name
Journal Of Petroleum Exploration And Production Technology
Characterization of flow units, rock and pore types for Mishrif Reservoir in West Qurna oilfield, Southern Iraq by using lithofacies data
...Show More Authors
Abstract<p>This study has been accomplished by testing three different models to determine rocks type, pore throat radius, and flow units for Mishrif Formation in West Qurna oilfield in Southern Iraq based on Mishrif full diameter cores from 20 wells. The three models that were used in this study were Lucia rocks type classification, Winland plot was utilized to determine the pore throat radius depending on the mercury injection test (r35), and (FZI) concepts to identify flow units which enabled us to recognize the differences between Mishrif units in these three categories. The study of pore characteristics is very significant in reservoir evaluation. It controls the storage mechanism and reservoir fluid prope</p> ... Show More
View Publication
Scopus (30)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
Chemical-Free Greywater Treatment Using Aeration, Sedimentation, Followed by Granular Activated Carbon Filter (GAC) -A Case Study of Baghdad city household
...Show More Authors

Greywater is a possible water source that can be improved for meeting the quality required for irrigation. Treatment of greywater can range from uncomplicated coarse filtration to advanced biological treatment. This article presents a simple design of a small scale greywater treatment plant, which is a series of physical and natural processes including screening, aeration, sedimentation, and filtration using granular activated carbon filter and differentiates its performance with sand filter. The performance of these units with the dual filter media of (activated carbon with sand) in treatment of greywater from Iraqi house in Baghdad city during 2019 and that collected from several points including washbasins, kitchen si

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
partial molal volume and viscosity study of vitamin B1 and B3 in water
...Show More Authors

the study covered theoretical concering parial molal volume the applicability of jones-dole equation

View Publication Preview PDF
Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Sulphite in Various Water Samples Via Chromium-1,5-Diphenylcarbazide Complex
...Show More Authors

A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri May 18 2018
Journal Name
International Journal Of Simulation: Systems, Science &amp; Technology
A Review of Advances in Pressurizer Response Research for Pressurized Water Reactor Systems
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Absorption of NO2 into Water and Nitric Acid Solutions in a Fixed Column
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Global Pharma Technology
Assessment of heavy metals in some ground water wells at Baghdad City/Iraq
...Show More Authors

Occurrence the heavy metals in water is one of the most important concerns. may cause savior health problems. In this work we made an attempt to know the quantity of six heavy metals in groundwater in different locations of Baghdad city. Examinations were made on groundwater of the review region to assess the heavy metals. Groundwater samples were gathered and analyzed utilizing Atomic Absorption Spectrophotometer for their Manganese, Iron, Zinc, Cadmium, Copper and Lead content and their levels compared with World Health Organization (WHO) specified maximum contaminant level. In order to accomplish this, water samples were obtained from 10 randomly selected wells in the region, in February and August, 2016. The study showed that the ground

... Show More
Preview PDF
Scopus (7)
Scopus
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of The Mechanical Behavior Of Materials
Simulation and assessment of water supply network for specified districts at Najaf Governorate
...Show More Authors
Abstract<p>This study aims to simulate and assess the hydraulic characteristics and residual chlorine in the water supply network of a selected area in Al-Najaf City using WaterGEMS software. Field and laboratory work were conducted to measure the pressure heads and velocities, and water was sampled from different sites in the network and then tested to estimate chlorine residual. Records and field measurements were utilized to validate WaterGEMS software. Good agreement was obtained between the observed and predicted values of pressure with RMSE range between 0.09–0.17 and 0.08–0.09 for chlorine residual. The results of the analysis of water distribution systems (WDS) during maximum demand </p> ... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Numerical Modeling of Water Movement from Buried Vertical Ceramic Pipes through Coarse Soils
...Show More Authors

Problem of water scarcity is becoming common in many parts of the world.  Thus to overcome this problem proper management of water and an efficient irrigation systems are needed.  Irrigation with buried vertical ceramic pipe is known as a very effective in management of irrigation water.  The two- dimensional transient flow of water from a buried vertical ceramic pipe through homogenous porous media is simulated numerically using the software HYDRUS/2D to predict empirical formulas that describe the predicted results accurately.   Different values of pipe lengths and hydraulic conductivity were selected.  In addition, different values of initial volumetric soil water content were assumed in this simulation a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref