Preferred Language
Articles
/
ijcpe-92
Extraction of Phenol from Aqueous Solutions Using Bulk ionic Liquid Membranes
...Show More Authors

Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl‐1‐methylimidazoliumhexafluorophosphate[Bmim][PF6],    

   1‐hexyl‐1‐methylimidazoliumhexafluorophosphate[Hmim][PF6], 1-butyl-1-methylpyrrolidinium bis (trifluoromethylsulfonyl) imide[Bmpyr][NTf2], and 1-octyl-3-methyl imidazolium tetra fluoroborate[Omim][BF4].

   The distribution coefficients for phenol in these ionic liquids were measured at different pH values and found to be much larger than those in conventional solvents. Through the values of the distribution coefficients and the experiments that were conducted on bulk liquid membrane applying various types of prepared ionic liquids, 1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide was selected as the best ionic liquid which gave the highest extraction and stripping efficiencies.

   The effect of several parameters, namely, feed phase pH(2-12), feed concentration(100-1000 ppm), NaOH concentration(0-0.5M), temperature (20-50oC), feed to membrane volume ratio (200-400ml/80ml ionic liquid) and stirring speeds(75-125 rpm) on the performance of the choosen ionic liquid membrane were also studied.    

   The preliminary study showed that high phenol extraction and stripping efficiencies of 97% and 95% respectively were achieved by ionic liquid membrane with a minimum membrane loss which offers a better choice to organic membrane solvents.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 18 2023
Journal Name
Asia-pacific Journal Of Chemical Engineering
Facile preparation of dual functions zeolite‐carbon composite for zinc ion removal from aqueous solutions
...Show More Authors
Abstract<p>The cost‐effective dual functions zeolite‐carbon composite (DFZCC) was prepared using an eco‐friendly substrate prepared from bio‐waste and an organic adhesive at intermediate conditions. The green synthesis method used in this study ensures that chemically harmless compounds are used to obtain a homogeneous distribution of zeolite over porous carbon. The greenly prepared dual‐function composite was extensively characterized using Fourier transform infrared, X‐ray diffraction, thermogravimetric analysis, N<sub>2</sub> adsorption/desorption isotherms, field emission scanning electron microscope, dispersive analysis by X‐ray, and point of zero charges. DFZCC had a surface area o</p> ... Show More
View Publication
Scopus (29)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Thu Nov 21 2013
Journal Name
Korean Journal Of Chemical Engineering
Removal of 4-nitro-phenol from wastewater using synthetic zeolite and kaolin clay
...Show More Authors

Adsorption techniques are widely used to remove certain classes of pollutants from wastewater. Phenolic compounds represent one of the problematic groups. Na-Y zeolite has been synthesized from locally available Iraqi kaolin clay. Characterization of the prepared zeolite was made by XRD and surface area measurement using N2 adsorption. Both synthetic Na-Y zeolite and kaolin clay have been tested for adsorption of 4-Nitro-phenol in batch mode experiments. Maximum removal efficiencies of 90% and 80% were obtained using the prepared zeolite and kaolin clay, respectively. Kinetics and equilibrium adsorption isotherms were investigated. Investigations showed that both Langmuir and Freundlich isotherms fit the experimental data quite well. On the

... Show More
View Publication
Scopus (24)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Thu Apr 03 2025
Journal Name
Journal Of The American Oil Chemists' Society
A novel deep eutectic solvent‐based liquid membrane for the extraction of glycerol from crude biodiesel
...Show More Authors
Abstract<p>This study used deep eutectic solvent (DES) as the liquid membrane in a bulk liquid membrane system (BLM) to remove glycerol from waste cooking oil‐based biodiesel. The DES was prepared from choline chloride and tetraethylene glycol at a molar ratio of 1:5. Diethyl ether was employed as a novel strip phase for the glycerol in BLM. The effects of the DES: biodiesel ratio, stirring speed, and extraction time on the extraction and stripping efficiencies were investigated. The results showed that BLM could give better glycerol removal from biodiesel than mechanical shaking. Increasing the DES: biodiesel ratio, stirring speed, and extraction time can enhance glycerol removal from the feed phase, achievi</p> ... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri May 10 2019
Journal Name
Research Journal Of Chemistry And Environment
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL-

... Show More
View Publication
Publication Date
Mon Jun 01 2020
Journal Name
Colloids And Surfaces A: Physicochemical And Engineering Aspects
Removal of antibiotic tetracycline using nano-fluid emulsion liquid membrane: Breakage, extraction and stripping studies
...Show More Authors

View Publication
Scopus (55)
Crossref (47)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Zn (II) and Cu (II) Ions Using PEG (300) - KCl Salt Aqueous Two-Phase Systems
...Show More Authors

In this paper the process of metal ions extraction (Zn(II) and Cu(II)) was studied in PEG-KCl aqueous two phase system was investigated without using an extracting agent. The experimental runs were performance at constant temperature (25 oC), constant mixing time (30 min), and constant PH of the solution (about 3). The effect of KCl salt concentration (from 10% to 25%), volumetric phase ratio of PEG solution to KCl solution (from 0.5 to 2), and the initial metal ion concentration (from 0.25 ml to 2 ml of 1 gm/L solution) were investigated on the percent extraction of Zn(II) and Cu(II). The results indicated that the percent extraction of metal ions increase with increasing of salt concentration and phase ratio, and slightly de

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2003
Journal Name
Turkish Journal Of Chemistry
Gas Chr Gas Chromatographic Separ aphic Separation of Phenol Deriv ation of Phenol Derivatives by Schiff- y SchiffBase Liquid Crystalline Stationary Phases
...Show More Authors

The chromatographic behaviour of liquid crystalline compounds benzylidene-p-aminobenzoic acid and 4-(p-methyl benzylidene)-p-aminobenzoic acid as stationary phases for the separation of dimethylphenol isomers was investigated. These isomers were analysed on benzylidene-p-aminobenzoic acid within a nematic range of 169-194 ◦C with a temperature interval of 5 ◦C. Better peak resolution was at a column temperature of 190 ◦C. The analysis was repeated on a 4-(p-methyl benzylidene)-p-aminobenzoic acid column at a nematic temperature of 256 ◦C, which represented the end of the nematic range, and gave the optimum peak resolution. It was found that isomer better separation was obtained at 20% loading for both liquid crystal materials. Other

... Show More
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Efficiency Study of Two Adsorbent Materials to Remove Eosin Y Dye from Aqueous Solutions
...Show More Authors

This study was done to find a cheap, available and ecofriendly materials that can remove eosin y dye from aqueous solutions by adsorption in this study, two adsorbent materials were used, the shells of fresh water clam (Cabicula fluminea) and walnut shells. To make a comparison between the two adsorbents, five experiments were conducted. First, the effects of the contact time, here the nut shell removed the dye quickly, while the C. flumina need more contact time to remove the dye. Second, the effects of adsorbent weight were examined. The nut shell was very promising and for all used adsorbent weight, the R% ranged from 94.87 to 99.29. However C. fluminea was less effective in removing the dye with R% ranged from 47.59 to 55.39. The thi

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue May 30 2017
Journal Name
Environmental Earth Sciences
Purification of aqueous solutions from Pb(II) by natural bentonite: an empirical study on chemical adsorption
...Show More Authors

View Publication
Scopus (15)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue May 30 2017
Journal Name
Environmental Earth Sciences
Purification of aqueous solutions from Pb(II) by natural bentonite: an empirical study on chemical adsorption
...Show More Authors

View Publication
Scopus (15)
Crossref (8)
Scopus Clarivate Crossref