Preferred Language
Articles
/
ijcpe-92
Extraction of Phenol from Aqueous Solutions Using Bulk ionic Liquid Membranes
...Show More Authors

Room temperature ionic liquids show potential as an alternative to conventional organic membrane solvents mainly due to their properties of low vapour pressure, low volatility and they are often stable. In the present work, the technical feasibilities of room temperature ionic liquids as bulk liquid membranes for phenol removal were investigated experimentally. In this research several hydrophobic ionic liquids were synthesized at laboratory. These ionic liquids include (1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Bmim][NTf2], 1-Hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide[Hmim][NTf2], 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl)imide[Omim][NTf2],1‐butyl‐1‐methylimidazoliumhexafluorophosphate[Bmim][PF6],    

   1‐hexyl‐1‐methylimidazoliumhexafluorophosphate[Hmim][PF6], 1-butyl-1-methylpyrrolidinium bis (trifluoromethylsulfonyl) imide[Bmpyr][NTf2], and 1-octyl-3-methyl imidazolium tetra fluoroborate[Omim][BF4].

   The distribution coefficients for phenol in these ionic liquids were measured at different pH values and found to be much larger than those in conventional solvents. Through the values of the distribution coefficients and the experiments that were conducted on bulk liquid membrane applying various types of prepared ionic liquids, 1-butyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide was selected as the best ionic liquid which gave the highest extraction and stripping efficiencies.

   The effect of several parameters, namely, feed phase pH(2-12), feed concentration(100-1000 ppm), NaOH concentration(0-0.5M), temperature (20-50oC), feed to membrane volume ratio (200-400ml/80ml ionic liquid) and stirring speeds(75-125 rpm) on the performance of the choosen ionic liquid membrane were also studied.    

   The preliminary study showed that high phenol extraction and stripping efficiencies of 97% and 95% respectively were achieved by ionic liquid membrane with a minimum membrane loss which offers a better choice to organic membrane solvents.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Rise Velocity and Drag Coefficient of Collapsing Two-Phase Bubble Condensing in an Immiscible Liquid
...Show More Authors

Collapse of the vapor  bubble condensing  in an immiscible  is investigated for  n-pentane and n-hexane vapors condensing in cold water and n-pentane in two different compositions of glycerin- water mixture. The rise velocity and the drag coefficient of the two-phase bubble are measured.

View Publication Preview PDF
Publication Date
Tue Apr 30 2024
Journal Name
Iraqi Journal Of Science
Detection of Anti-cancer Activity of Silver Nanoparticles Synthesized using Aqueous Mushroom Extract of Pleurotus ostreatus on MCF-7 Human Breast Cancer Cell Line
...Show More Authors

     In this research, silver nanoparticles (AgNPs) were manufactured using aqueous extract of mushroom Pleurotus ostreatus. Anticancer potential of AgNPs was investigated versus human breast cancer cell line (MCF-7). Cytotoxic response was assessed by MTT assay. AgNPs showed inhibition effect at the following concentrations 12.5, 25, 50, 100 and 200 µg/ml versus MCF-7 cell line, and all treatments had a positive result. The MCF-7 cells were inhibited up to 85.14 % at the concentration 200 μg/ml of AgNPs which reduced cells viability to 14.86%, while 12.5 μg/ml of AgNPs caused 24.23% cells inhibition with reduction of cells viability to 75.77%.

View Publication
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Diyala Agricultural Sciences Journal
Effect of Some Preservative Solutions on Some Morphometric Features of Planiliza abu (Heckel, 1843)
...Show More Authors

The present study attempts to find out the effect of some fish preservatives in the laboratory, such as alcohol and dilute formalin, on some biological characteristics related to the body measurements of those fish preserved in these materials. The fish used in this study were the local Planiliza abu. The processes of expansion and contraction of the bodies of fish preserved in diluted formalin solution at a concentration of 10% and diluted ethyl alcohol solution at a concentration of 70%. As that the standard length of the specimens of this study, which are separately preserved in formalin 10% and alcohol 70%, in a completely isolated are fluctuating in change. Constant shrinkage in head length in both diluted formalin and alcohol.

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jun 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effects of different concentrations of Alum solutions on Mutans streptococci (in vitro study)
...Show More Authors

Background: Alum has been used as a treatment medication in cases of oral and gingival ulcers, and also as antiseptic mouthwash. This study aimed to examine the effects of different concentrations of Alum on inhibition zone, viability counts and adherence ability of Mutans streptococci compared with deionized water and chlorhexidine gluconate in vitro. Materials and methods: The study dealt with an in vitro study to establish a concentration of Alum mouthrinse that would have the minimum inhibitory concentration and minimum bacteriocidal concentration. The second part evaluated the anti-adherence ability of the experimental agents. Results: This study found that the antibacterial effect of Alum increases with its concentration from 50 to 1

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 01 2024
Journal Name
Case Studies In Chemical And Environmental Engineering
Congo red removal from aqueous solution by electrocoagulation- electro-oxidation combined system with Al and Cu–Mn–Ni nano composite as efficient electrodes
...Show More Authors

Removing Congo red (CR) is critical in wastewater treatment. We introduce a combination of electrocoagulation (EC) and electro-oxidation (EO) to address the elimination of CR. We also discuss the deposition of triple oxides (Cu–Mn–Ni) simultaneously on both anodic and cathodic graphite electrodes at constant current density. These electrodes efficiently worked as anodes in the EC-EO system. The EC-CO combination eliminated around 98 % of the CR dye and about 95 % of the Chemical Oxygen demand (COD), and similar results were obtained with the absence of NaCl. Thus, EC-EO is a promising technique to remove CR in an environmentally friendly pathway.

View Publication
Scopus (11)
Crossref (7)
Scopus Crossref
Publication Date
Sun Mar 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Pyrolysis of High-density Polyethylene for the Production of Fuel-like Liquid Hydrocarbon
...Show More Authors

Pyrolysis of high density polyethylene (HDPE) was carried out in a 750 cm3 stainless steel autoclave reactor, with temperature ranging from 470 to 495° C and reaction times up to 90 minute. The influence of the operating conditions on the component yields was studied. It was found that the optimum cracking condition for HDPE that maximized the oil yield to 70 wt. % was 480°C and 20 minutes. The results show that for higher cracking temperature, and longer reaction times there was higher production of gas and coke. Furthermore, higher temperature increases the aromatics and produce lighter oil with lower viscosity.

View Publication Preview PDF
Publication Date
Mon May 22 2023
Journal Name
Journal Of Optics
The influence of gold nanoparticles on electro-optical properties of nematic liquid crystal
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Nonlinear optical properties of liquid crystal doped with different concentrations of carbon nanotubes
...Show More Authors

View Publication
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Dec 29 2023
Journal Name
Studia Chemia
THERMODYNAMIC STUDY OF SOME ALCOHOLS IN DILUTE AQUEOUS SOLUTION
...Show More Authors

Scopus
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Transference Number Measurement of Zinc Salts in Aqueous Solution
...Show More Authors

Transference numbers of the aqueous zinc chloride and zinc sulphate solutions have been measured for the concentrations 0.03, 0.05, 0.07, 0.09 and 0.1 mol.dm-3at 298.15K, by using the modified Hittorf method. The dependence of transference number on concentration of each electrolyte was also investigated in an attempt to explain the value of the limiting transference number. The Longsworth method has been used for the extrapolation of zinc transference number in aqueous solutions, using the values of the limiting transference numbers of the appropriate values of the limiting equivalent conductance, it was possible to determine the corresponding values of the limiting ion conductance for the cations and anions of the electrolytes. The

... Show More
View Publication Preview PDF
Crossref