Determining Optimum Oil Separator Size and Optimum Operating Pressure

The optimum separators operating pressure is determined by using flash calculations and equilibrium ratios. In this study, the optimum separator size for Jambur field is calculated by using equations introduced by Arnold and Stewart and API12J Specification [1]. Because Jambur field has a high production rate two conditions are taken in the study to determine separator size, first based on production rate 80,000 bbl/day and second based on split the production between two banks A and B (40,000 bbl/day for each bank). The calculation resulted in optimum separator pressure for the first stage of 700 psi, and the second stage of 300 psi, and the third stage of 120 psi. The results show that as the number of stages increased above three-stage for Jambur field less incremental liquid recovery achieved and this will not cover the cost of adding an extra stage.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 05 2017
Journal Name
Neural Computing And Applications
Scopus (34)
Crossref (30)
Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Science
Determining the Best Rainwater Harvesting System in Al-Muthanna Governorate, Iraq

     Rainwater harvesting is one of the available solutions to overcome water scarcity in arid and semi-arid regions with highly variable rainfall and unexpected periods of drought or floods. This study aims to identify the best rainwater harvesting system in Al-Muthanna governorate using Remote Sensing (RS) and Geographic Information System (GIS) techniques. Landsat 8 images were used to produce the land use map which shows five different classes: water (0.2%), bare soil (82.11%), built-up (15.71%), forest (0.27%), and farmland and grass (1.71%). The results revealed that the rainwater harvesting system can be applied only in the north and north-eastern parts of the study area which consists of residential and agricultural areas and

... Show More
Scopus (3)
Crossref (1)
Scopus Crossref
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Night Vision monitor for IR laser spot size Identification

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Effect of laparoscopic sleeve gastrectomy on blood sugar and blood pressure

Background: Surgery is one and may be the most effective method to treat obesity. In the last decade, Laparoscopic Sleeve Gastrectomy is perceived to be less invasive, technically simple, less morbid and more popular form of bariatric surgery.

Objectives: This study aims to assess the effect of Laparoscopic Sleeve Gastrectomy on Fasting Blood Glucose Levels and Blood Pressure.

 Methods: A prospective controlled study in which 50 obese patients were involved, 36 of patients have hypertension and type 2 diabetes mellitus , 7 patients have type 2 diabetes mellitus only, and 7 patients don’t have hypertension or type 2 diabetes. All patients were submitted to Laparosco

... Show More
Crossref
View Publication Preview PDF
Publication Date
Wed Dec 12 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
Preparation and characterization DLC thin films using atmospheric pressure plasma Jet

Diamond-like carbon, amorphous hydrogenated films forms of carbon, were pretreated from cyclohexane (C6H12) liquid using plasma jet which operates with alternating voltage 7.5kv and frequency 28kHz. The plasma Separates molecules of cyclohexane and Transform it into carbon nanoparticles. The effect of argon flow rate (0.5, 1 and 1.5 L/min) on the optical and chemical bonding properties of the films were investigated. These films were characterized by UV-Visible spectrophotometer, X-ray diffractometer (XRD) Raman spectroscopy and scanning electron microscopy (SEM). The main absorption appears around 296, 299 and 309nm at the three flow rate of argon gas. The value of the optical energy gap is 3.37, 3.55 and 3.68 eV at a different flow rate o

... Show More
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
EFFECT OF PVD AND VACUUM PRESSURE ON SATURATED-UNSATURATED SOFT SOILS

    Soft clays are generally sediments deposited by rivers, seas, or lakes. These soils are fine-grained plastic soils with appreciable clay content and are characterized by high compressibility and low shear strength. To deal with soft soil problems there is more than one method that can be used such as soil replacement, preloading, stone column, sand drains, lime stabilization and Prefabricated Vertical Drains, PVDs. A numerical modeling of PVD with vacuum pressure was analyzed to investigate the effect of this technique on the consolidation behavior of fully and different depths of partially saturated soft soils.  Laboratory experiments were also conducted by using a specially-designed large consol

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Dual Measurements of Pressure and Temperature With Fiber Bragg Grating Sensor

Abstract

The fiber Bragg grating (FBG) technology has been rapidly applied in the sensing technology field. In this work, uniform FBG was used as pressure sensor based on measuring related Bragg wavelength shift. The pressure was applied directly by air compressor to the sensor and the pressure was ranged from 1 to 6 bar.

      This sensor also was affected by the external temperature so as a result it could be used as a temperature sensor. This sensor could be used to monitor the pressure of dams. It has been shown from the result that the sensor is very sensitive to the pressure and the sensitivity was (67 pm\bar) and is very sensitive to temperature and the sensitivity was (10p

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 01 2022
Journal Name
Political Sciences Journal
The The US Pressure and Sanctions Policy in Changing Iran's Conduct

This research aims to analyze the impact of the United States policy of pressure and sanctions on changing Iran's conduct. Since the Islamic Revolution of Iran in 1979, the US has continuously pursued various policies towards Iran, aiming to change the regime by force or isolate it politically and economically. The main research question lies in the following: To what extent does the US pressure policy and its sanctions affect the conduct Iran?. This research discusses that the more there are economic and political alternatives to Iran, the more it will be challenging the US demands. Moreover, the more the US pursues a negotiating policy based on mutual interests, the more Iran will positively respond to American demands.

Crossref
View Publication Preview PDF
Publication Date
Tue Jan 01 2013
Journal Name
Journal Of Geochemical Exploration
Crossref (34)
Crossref
View Publication
Publication Date
Thu Dec 30 2021
Journal Name
Al-kindy College Medical Journal
Palestinian Experience in Stage Four Pressure Ulcer

Pressure ulcer (now called Pressure injury) happens when the bony prominence like the sacrum exposes to pressure for a long period and also can cause soft tissue injury. In order to prevent and cure pressure-induced wounds, continuous and attentive repositioning is necessary. Wound management begins with the identification and aggressive management of the modifiable factors, such as positioning, incontinence, spasticity, diet, devices, and medical comorbidity, which contribute to pressure injury formation. Initial interventions include washing, cleaning, and maintaining the surfaces of the wound. In certain cases, it may be sufficient to debride the non-viable or contaminated tissue; however, operational care in more severe cases

... Show More
Crossref
View Publication Preview PDF