The behavior of AC conductivity (σac), loss tangent (tan δ), and relative permittivity (ε′) for composites of PVC-P/graphite electrode waste (GEW) was investigated, and a qualitative explanation was provided as a function of PVC-P weight fractions (0, 5, 10, 15, 20, and 25) wt. percent, temperature (30-90) °C, and frequency (100Hz-2MHz). The behaviors of the composites' ac. conductivity and impedance as a frequency function and temperature have been examined. The permittivity was shown to rise with increasing temperature (Tg). The relative permittivity increased as the GEW filler concentration increased and was highest in the low-frequency range; nevertheless decreased as the frequency increased.
This study attempts to determine the necessary teaching competencies for teachers and the level of their importance in the development of their performance professionally and scientifically, and the progress towards a better future to achieve an effective level. Accordingly, the research community consists of the morning-preparatory schools for boys at the General Directorate of Education of Baghdad \ Rusafa2. The study sample included (68) teachers constituted 88.31% of the total community of teachers. As for the research tools, the researcher adopted the descriptive method by using the observation method in which the researcher prepared a list of teaching. For verifying the re
... Show MoreCold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t
Background: Asthma is one of the most common chronic respiratory diseases in the world, standing for the most frequent cause for hospitalization and emergency cases. Respiratory viruses are the most triggering cause. Aim: To assess the role of viral infections, especially COVID-19, in the pathogenesis of asthma initiation and exacerbations. Method: Electronic search was done for the manuscripts focusing on asthma as a risk factor for complications after COVID-19 infection. The outcomes were titles, materials, methods and classified studies related or not related to the review study. Three hundred publications were identified and only ten studies were selected for analysis. Seven studies were review, one retrospective, one longitudin
... Show MoreMy study here is about the (possible for itself) features especially in the (Alashaira) opinion, also I touch to the other logicians opinions, I clarified these features concisely in the preface to be clear in front of the reader, I made it in two studies and five subjects.I talked about the meaning of the existence in the ((possible for itself) theme, and I clarified its types in the logicians and the philosophers' opinions, through which the existence and the nonexistence are equal in it, as it cannot be existed nor be nonsexist unless with a separated reason, and there is no necessity to oblige its existence, or its nonexistence is impossible.Then I talked about the outweighing of the (possible for itself) as one side of the exi
... Show MoreThe aim of this work is to evaluate the onc-electron expectation values < r > from the radial electronic density funetion D(r) for different wave ?'unctions for the 2s state of Li atom. The wave functions used were published in 1963,174? and 1993 , respectavily. Using " " ' wave function as a Slater determinant has used the positioning technique for the analysis open shell system of Li (Is2 2s) State.
The quality and cost of constructed buildings are heavily influenced by the performance of design/auditing consultants. Thus, selecting the right design consultant and design auditing consultants is of utmost importance and not an easy task for any construction client. so, the client should specify the efficiency criteria and assess the performance levels of the design and design auditing consultant firm. The study aims to identify the selection criteria of the design consultant in construction projects and also identify the selection criteria of the design auditing consultant for the construction projects by using the Delphi survey with applying the principal components analysis (PCA
Suggestion Plan for the Reclassification of U.N Publications in Central Library
The study aimed at clarifying the contradictions of the general industrial companies despite the investment allocations and the government investment expenditure on manufacturing activities under the so- called rehabilitation programs. However, this did not contribute to a certain extent in the growth and industrial leap in the direction of developing the activities of the sector Industrial sector in Iraq because of the lack of adoption of a number of basic principles towards the need to take priority of investment in the field of manufacturing and industrial decision-making in the restructuring of industry according to the priorities of investment in light of the international industrial trend, Tosmarah available to the manufact
... Show MoreThis paper was aimed to study the efficiency of forward osmosis (FO) process as a new application for the treatment of wastewater from textile effluent and the factors affecting the performance of forward osmosis process.
The draw solutions used were magnesium chloride (MgCl2), and aluminum sulphate (Al2 ( SO4)3 .18 H2O), and the feed solutions used were reactive red, and disperse blue dyes.
Experimental work were includes operating the forward osmosis process using thin film composite (TFC) membrane as flat sheet for different draw solutions and feed solutions. The operating parameters studied were : draw solutions concentration (10 – 90 g/l), feed solutions concentration (5 – 30 mg/l), draw solutions flow rate (10 – 50 l/hr