Preferred Language
Articles
/
ijcpe-83
CFD Simulation of Air Flow Patterns in a Spray Dryer Fitted With a Rotary Disk
...Show More Authors

The air flow pattern in a co-current pilot plant spray dryer fitted with a rotary disk atomizer was determined experimentally and modelled numerically using Computational Fluid Dynamics (CFD) (ANSYS Fluent ) software. The CFD simulation used a three dimensions system, Reynolds-Average Navier-Stokes equations (RANS), closed via the RNG k −ε turbulence model. Measurements were carried out at a rotation of the atomizer (3000 rpm) and when there is no rotation using a drying air at 25 oC and  air velocity at the inlet of  5 m/s without swirl. The air flow pattern was predicted experimentally using cotton tufts and digital anemometer. The CFD simulation predicted a downward central flowing air core surrounded by a slow recirculation zones near the walls for both conditions. Analysis of CFD simulation revealed that rotation of atomizer resulted in a swirling motion of the central air core. Simulations results were in good agreement with experimental data.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 05 2024
Journal Name
International Journal Of Science And Research (ijsr)
Evaluation of Adherence to Methotrexate in a Sample of Iraqi Patients with Rheumatoid Arthritis Receiving Anti - TNF Medications
...Show More Authors

View Publication
Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of Engineering
Numerical Study of Convective Heat Transfer in a Rectangular Channel Inserted with Metal Foam of Gradient Pore Density
...Show More Authors

Metal foam has recently been used in many engineering applications, such as solar collectors, heat exchangers, and cooling of electronic devices, which calls for studying different cases of using metal foam in these applications. The current study conducts a numerical analysis of heat transfer and fluid flow characteristics for air in a rectangular channel filled with high-porosity copper foam. The study examined the thermal performance for two cases of gradient pore density, which are arranged as (10-20-40) PPI and (40-20-10) PPI. These cases were compared with two other cases for constant pore density, 10 and 40 PPI, and empty cases. The ANSYS FLUENT 20.0 employed the Darcy-Forchheimer extended Brickman model in the two-dimensiona

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Mar 03 2022
Journal Name
Archives Of Rheumatology
Association of tumor necrosis factor-alpha promoter region gene polymorphism at positions -308G/A, -857C/T, and -863C/A with etanercept response in Iraqi rheumatoid arthritis patients
...Show More Authors

Objectives: This study aims to evaluate the association between polymorphisms in the promoter region of the tumor necrosis factor-alpha (TNF-α) gene at locations -308G/A, -857C/T, and -863C/A with the tendency of being non-responder to etanercept.

Patients and methods: Between October 2020 and August 2021, a total of 80 patients (10 males, 70 females; mean age: 50 years; range, 30 to 72 years) with rheumatoid arthritis (RA) receiving etanercept for at least six months were included. The patients were divided into two groups responders and non-responders, based on their response after six months of continuous treatment. Following polymerase chain reac

... Show More
View Publication Preview PDF
Scopus (18)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Res Militaris
Patterns of thinking about chemical identity among students of the College of Education for Pure Sciences - Ibn Al-Haytham in Iraq
...Show More Authors

Preview PDF
Publication Date
Sat Mar 01 2014
Journal Name
Renewable Energy
Field study of various air based photovoltaic/thermal hybrid solar collectors
...Show More Authors

In the present work a comparative study for thermal and electrical performance of different hybrid photovoltaic/thermal collectors designs for Iraq climate conditions have been carried out. Four different types of air based hybrid PV/T collectors have been manufactured and tested. Three collectors consist of four main parts namely, channel duct, glass cover, axial fan to circulate air and two PV panels in parallel connection. The measured parameters are, the temperature of the upper and the lower surfaces of the PV panels, air temperature along the collector, air flow rate, pressure drop, power produced by solar cell, and climate conditions such as wind speed, solar radiation and ambient temperature. The thermal and hydraulic performances o

... Show More
View Publication
Scopus (124)
Crossref (111)
Scopus Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit Using RSM Technique
...Show More Authors

The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Experimental study for the properties of Fe3O4 dusty plasma using the air in vacuum chamber system
...Show More Authors

In this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperatu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
Effect of the Iranian Seperation Dikes on the Water Salinity Patterns Within Al Huweizah Marsh
...Show More Authors

Al Huweizah Marsh is considered as the largest marsh at the southern part of Iraq. About one third of the marsh is located within the Iranian territory. Iran began to construct earth dikes along the Iraqi-Iranian international borders to separate the Iranian part of the marsh. The electrical conductivity, EC, value was adopted to be the indicator for the water salinity within the marsh. A steady two-dimensional water quality routing model was implemented by using the RMA2 and RMA4 softwares within the SMS computer package to estimate the distribution of the
EC values within the marsh seasonally during the wet, moderate and dry water years. The EC distribution Patterns were estimated considering the expected two cases of the marsh futu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Major inflammatory patterns of chronic sinonasal diseases and their accompanied anatomical variations; CT scan review
...Show More Authors

Background: Because of wide use of Functional Endoscopic Sinus Surgery (FESS) technique in the recent years and basic role of coronal computed tomography (CT) scan in demonstrating the normal drainage route of para-nasal sinuses, identifying the major patterns of inflammatory sinonasal disease and accompanied anatomical variations is essential for appropriate preoperative surgical planning. In review of publisthed literature, there is no data on CT patterns of chronic inflammatory sinonasal disease and their accompained anatomical variations of nose and PNS in our local population.Objectives: was to determine the frequency of CT patterns and variations in patients with sinonasal symptoms.Methods: This was a cross sectional descriptive st

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Numerical Research on Flow-Induced Vibration in Valves
...Show More Authors

Abstract  

All central air conditioning systems contain piping system with various components, sizes, material, and layouts. If such systems in operating mode, the flow in piping system and its component such as valves can produce severe vibration due to some flow phenomenon’s. In this research, experimental measurements and numerical simulation are used to study the flow-induced vibration in valves. Computational fluid dynamics (CFD) concepts are included with one-way and two-way fluid-structure interaction concepts by using finite element software Package (ANSYS 14.57). Detection analysis is performed on flow characteristics under operation conditions and relations with structural vibration. Most of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref