Preferred Language
Articles
/
ijcpe-821
Treating Wet Oil in Amara Oil Field Using Nanomaterial (SiO2) With Different Types of De emulsifiers
...Show More Authors

One of the most important problems in the oil production process and when its continuous flow, is emulsified oil (w/o emulsion), which in turn causes many problems, from the production line to the extended pipelines that are then transported to the oil refining process. It was observed that the nanomaterial (SiO2) supported the separation process by adding it to the emulsion sample and showed a high separation rate with the demulsifiers (RB6000) and (sebamax) where the percentage of separation was greater than (90 and 80 )%  respectively, and less than that when dealing with (Sodium dodecyl sulfate and Diethylene glycol), the percentage of separation was (60% and 50%) respectively.

   The high proportion of (NaCl + distilled water) raises the probability of the separation efficiency as the separation was (88.5,79)% and (65.5, 55) %  for (RB6000, SebaMax)respectively with (SiO2) at 70 °C, while the results of separation were (77,85)% and (65,40)  for (RB6000, Seba Max) respectively with (SiO2) at 50 °C after 120 minutes, where the (w/o ratio) was (9:1) for the high separation results and (7:3) for the lower separation results, at a speed of (12000rpm), and with a salt concentration of (1500) ppm, and less of these results at lower volumetric and temporal conditions. The (NaCl) salt deals with the wall films separating the droplets and reduces their viscosity [1].

   As for the pH factor, it is at the value (2 and 3) represent a stable emulsion that is difficult to separate easily, but with the passage of raising the pH away from the acidic medium and near to the basic direction, a significant increase in the separation process was observed compared with the acidic medium at lower values, after 120 minutes the separation seemed to be good efficient, reaching (60 and 70) % respectively, while at the same time the emulsion reached a more efficient separation level with a pH of (  8 and 7) equal to (80 and 87.3)  %, at 50 °C with SebaMax demulsifier in presence of (SiO2), and with the same pH values, an increase was observed in the separation with the increase in temperature to (70 °C), then it returns to be a reverse emulsifier when the value exceeds (10) to (11, 12, 13).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Study the Effect of Different Reinforcements on the Damping Properties of the Polymer Matrix Composite
...Show More Authors

In this research, damping properties for composite materials were evaluated using logarithmic decrement method to study the effect of reinforcements on the damping ratio of the epoxy matrix. Three stages of composites were prepared in this research. The first stage included preparing binary blends of epoxy (EP) and different weight percentages of polysulfide rubber (PSR) (0%, 2.5%, 5%, 7.5% and 10%). It was found that the weight percentage 5% of polysulfide was the best percentage, which gives the best mechanical properties for the blend matrix. The advantage of this blend matrix is that; it mediates between the brittle properties of epoxy and the flexible properties of a blend matrix with the highest percentage of PSR. The second stage

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Electrical Insulation Breakdown Strength and Thermal Conductivity of Different Blended Nanocomposites of New Epoxy Resins
...Show More Authors

This research studies the development and synthesis of blended nanocomposites filled with Titanium dioxide (TiO2). Blended nanocomposites based on unsaturated polyester resin (UPR) and epoxy resins were synthesized by reactive blending. The optimum quantity from nano partical of titanium dioxide was selected and different weight proportions 1%, 3%, 5%, and 7% ratios of new epoxy are blended with UPR resin. The dielectric breakdown strength and thermal conductivity properties of the blended nanocomposites were compared with those of the basis material (UPR and 3% TiO2).The results show good compatibility epoxy resins with the UPR resin on blending, dielectric breakdown strength values  are higher while thermal conductivity values of

... Show More
View Publication
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Clinical Dentistry
THE EFFECT OF A PROTECTIVE BARRIER ON THE SHEAR BOND STRENGTH OF DIFFERENT ORTHODONTIC BRACKETS
...Show More Authors

Background and objectives: This study aimed at testing the effect of plastic sleeve or barrier, used to cover the guide of the light cure unit to prevent cross-infection, on the shear bond strength and site of bond failure of stainless steel and ceramic orthodontic brackets. Materials and methods: Forty orthodontic brackets; twenty stainless steel and twenty ceramic brackets bonded to forty extracted human maxillary first premolars using light cure adhesive cured with and without the use of a protective plastic barrier on the guide. Comparing the effect of this barrier on the shear bond strength and adhesive remnant index was performed using an independent t-test and Chi-square test. Results: The protective barrier had decreased the shear b

... Show More
Scopus (3)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
Aims Energy
The impact of different compression ratios on emissions, and combustion characteristics of a biodiesel engine
...Show More Authors

<p>The current work investigated the combustion efficiency of biodiesel engines under diverse ratios of compression (15.5, 16.5, 17.5, and 18.5) and different biodiesel fuels produced from apricot oil, papaya oil, sunflower oil, and tomato seed oil. The combustion process of the biodiesel fuel inside the engine was simulated utilizing ANSYS Fluent v16 (CFD). On AV1 diesel engines (Kirloskar), numerical simulations were conducted at 1500 rpm. The outcomes of the simulation demonstrated that increasing the compression ratio (CR) led to increased peak temperature and pressures in the combustion chamber, as well as elevated levels of CO<sub>2</sub> and NO mass fractions and decreased CO emission values un

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of the Hardness of Cold Cured Acrylic Resin Material by Processing at Different Temperature
...Show More Authors

Objective(s): This study aims to evaluate the hardness of two commercially available cold cured acrylic resin material
(Vertex and PAN) when polymerized at different temperature in comparison to those polymerized by conventional
methods in air at 23C ± 5C.
Methodology: Eighty specimens, forty from cold cured acrylic (Vertex Type) and forty from cold cured acrylic (PAN
type) were prepared, flasking and packing procedure were done according to manufacturer direction and divided
according to processing as follow: 20 specimens (10 from Vertex type and 10 from PAN type) were processed in air for
two hours at 23C ± 5C under press (bench curing) as a control, and 60 specimens (30 from Vertex type and 30 from
PAN type) wer

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of different curing distances on the microhardness of flowable bulk-fill composite materials
...Show More Authors

Background: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For e

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sat Sep 01 2018
Journal Name
Polimery
Synthesis and properties of vinylpyrrolidone/ (trimethoxysilyl)propyl methacrylate gels containing different amounts of crosslinking agent
...Show More Authors

View Publication
Scopus (12)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Nov 26 2017
Journal Name
Journal Of Engineering
The Dynamic Behavior of Water Flowing Through Packed Bed of Different Particle Shapes and Sizes
...Show More Authors

An experimental study was conducted on pressure drop of water flow through vertical cylindrical packed beds in turbulent region and the influence of the operating parameters on its behavior. The bed packing was made of spherical and non-spherical particles (spheres, Rasching rings and intalox saddle) with aspect ratio range 3.46  D/dp  8.486 obtaining bed porosities 0.396 0.84 and Reynolds number 1217  21758. The system is consisted of 5 cm inside diameter Perspex column, 50 cm long; distilled water was pumped through the bed with flow rate 875, 1000, 1125, 1250,1375 and 1500 l/h and inlet water temperature 20, 30, 40 and 50 ˚C. The packed bed system was monitored by using LabVIEW program, were the result

... Show More
View Publication Preview PDF
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
Capability of a novel small field of view hybrid gamma camera (HGC) for sentinel lymph node and small organ imaging
...Show More Authors

Objectives: Small field of view gamma detection and imaging technologies for monitoring in vivo tracer uptake are rapidly expanding and being introduced for bed-side imaging and image guided surgical procedures. The Hybrid Gamma Camera (HGC) has been developed to enhance the localization of targeted radiopharmaceuticals during surgical procedures; for example in sentinel lymph node (SLN) biopsies and for bed-side imaging in procedures such as lacrimal drainage imaging and thyroid scanning. In this study, a prototype anthropomorphic head and neck phantom has been designed, constructed, and evaluated using representative modelled medical scenarios to study the capability of the HGC to detect SLNs and image small organs. Methods: An anthropom

... Show More
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
A Modified Support Vector Machine Classifiers Using Stochastic Gradient Descent with Application to Leukemia Cancer Type Dataset
...Show More Authors

Support vector machines (SVMs) are supervised learning models that analyze data for classification or regression. For classification, SVM is widely used by selecting an optimal hyperplane that separates two classes. SVM has very good accuracy and extremally robust comparing with some other classification methods such as logistics linear regression, random forest, k-nearest neighbor and naïve model. However, working with large datasets can cause many problems such as time-consuming and inefficient results. In this paper, the SVM has been modified by using a stochastic Gradient descent process. The modified method, stochastic gradient descent SVM (SGD-SVM), checked by using two simulation datasets. Since the classification of different ca

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (6)
Scopus Clarivate Crossref