Preferred Language
Articles
/
ijcpe-821
Treating Wet Oil in Amara Oil Field Using Nanomaterial (SiO2) With Different Types of De emulsifiers
...Show More Authors

One of the most important problems in the oil production process and when its continuous flow, is emulsified oil (w/o emulsion), which in turn causes many problems, from the production line to the extended pipelines that are then transported to the oil refining process. It was observed that the nanomaterial (SiO2) supported the separation process by adding it to the emulsion sample and showed a high separation rate with the demulsifiers (RB6000) and (sebamax) where the percentage of separation was greater than (90 and 80 )%  respectively, and less than that when dealing with (Sodium dodecyl sulfate and Diethylene glycol), the percentage of separation was (60% and 50%) respectively.

   The high proportion of (NaCl + distilled water) raises the probability of the separation efficiency as the separation was (88.5,79)% and (65.5, 55) %  for (RB6000, SebaMax)respectively with (SiO2) at 70 °C, while the results of separation were (77,85)% and (65,40)  for (RB6000, Seba Max) respectively with (SiO2) at 50 °C after 120 minutes, where the (w/o ratio) was (9:1) for the high separation results and (7:3) for the lower separation results, at a speed of (12000rpm), and with a salt concentration of (1500) ppm, and less of these results at lower volumetric and temporal conditions. The (NaCl) salt deals with the wall films separating the droplets and reduces their viscosity [1].

   As for the pH factor, it is at the value (2 and 3) represent a stable emulsion that is difficult to separate easily, but with the passage of raising the pH away from the acidic medium and near to the basic direction, a significant increase in the separation process was observed compared with the acidic medium at lower values, after 120 minutes the separation seemed to be good efficient, reaching (60 and 70) % respectively, while at the same time the emulsion reached a more efficient separation level with a pH of (  8 and 7) equal to (80 and 87.3)  %, at 50 °C with SebaMax demulsifier in presence of (SiO2), and with the same pH values, an increase was observed in the separation with the increase in temperature to (70 °C), then it returns to be a reverse emulsifier when the value exceeds (10) to (11, 12, 13).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 24 2021
Journal Name
Oncology And Radiotherapy
The effect of different clinicopathological parameters on disease free survival in triple negative breast cancer Iraqi women
...Show More Authors

Scopus (1)
Scopus
Publication Date
Fri Oct 01 2021
Journal Name
Nonlienear Optics Quantum Optics
Narrow Emission Linewidth of Highly-Pure Silicon Nitride Nanoparticles in Different Dye Solutions as Random Gain Media
...Show More Authors

In this work, two different laser dye solutions were used to host highly-pure silicon nitride nanoparticles as scattering centers to fabricate random gain media. The laser dye was dissolved in three different solvents (ethanol, methanol and acetone) and the final results were obtained for methanol only. The silicon nitride nanoparticles were synthesized by dc reactive magnetron sputtering technique with average particle size of 35 nm. The random gain medium was made as a solid rod with high spectral efficiency and low production cost. Optical emission with narrow linewidth was detected at 532-534 nm as 9 mg of silicon nitride nanoparticles were added to the 10 -5 M dye solution. The FWHM of 0.3 and 3.52 nm was determined for Rhodamine B and

... Show More
View Publication
Publication Date
Sun Jan 01 2017
Journal Name
Engineering And Technology Journal
Study of the Diffusion Coefficient and Hardness for a Composite Material when Immersed in Different Solutions Polymer
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Thu Aug 01 2024
Journal Name
Russian Journal Of Bioorganic Chemistry
Synthesis, Characterization of Different Five-Membered Heterocyclic Derivatives, Evaluated Their as Antioxidant, and In Vitro Antimicrobial Agents
...Show More Authors

Objective:This study involved synthesis of a new series of different five-membered heterocyclic derivatives, testing their antioxidant activity, and examining their potential in vitro antimicrobial agents. Methods: The synthesis of the derivatives involved a three-step process. Initially, succinyl chloride was reacted with methanol, followed by a reaction with 80% hydrazine hydrate through a nucleophilic addition-elimination mechanism, resulting in the formation of succinohydrazide (I). This compound was then employed as a precursor for the synthesis of Schiff bases (II), and (III) by reacting it with m-nitro benzaldehyde and p-nitro benzaldehyde. Following this, a ring closure reaction was applied using thioglycolic acid, glycolic acid,

... Show More
View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Study the effect of the different doses from the laser on Staphylococcus aureus Bacteria growth in vitro
...Show More Authors

Background: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite l

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Wed May 18 2016
Journal Name
مجلة كلية التربية الاساسية
Study the Partial Molar Volume of Chrom Alum in Aqueous Poly (ethylene glycol) Solution at Different Temperature
...Show More Authors

This study present, the density of alum chrom in water and in aqueous solution of poly (ethylene glycol) (1500) at different temperature (288.15, 293.15, 298.15) k. Experimental values of density was used to calculate the apparent molar volume (Vθ), limiting apparent molar volume Vθ˚, experimental slope (Sv) and the partial molar volume at infinite dilution of transfer of solute Δνθ˚. These results have been interpreted the molecular interaction in term of ion- solvent, ion– ion interaction. The structure making /breaking capacities have been inferred from the sign of the second derivative of limiting partial molar volume with respect temperature at constant pressure. Alum has been formed to act as structure breaker in water and aq

... Show More
Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Reliability of Two Different Laser Wavelengths in Inducing Bone Healing Around Dental Implants: Comparative Clinical Trial
...Show More Authors

Background/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 29 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)
...Show More Authors

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
2016 Ieee Nuclear Science Symposium, Medical Imaging Conference And Room-temperature Semiconductor Detector Workshop (nss/mic/rtsd)
Comparison of columnar and pixelated scintillators for small field of view hybrid gamma camera imaging
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Jan 29 2026
Journal Name
Journal Of Physical Education
The impact of a training field in Lake Al-Razzaza to develop the strength of the legs and arms for young boxers
...Show More Authors

View Publication