Preferred Language
Articles
/
ijcpe-817
Removal of Acetaminophen Residues from Wastewater by Bulk Liquid Membrane Process
...Show More Authors

   The removal of Anit-Inflammatory drugs, namely; Acetaminophen (ACTP), from wastewater by bulk liquid membrane (BLM) process using Aliquat 336 (QCl) as a carrier was investigated. The effects of several parameters on the extraction efficiency were studied in this research, such as the initial feed phase concentration (10-50) ppm of ACTP, stripping phase (NaCl) concentration (0.3,0.5,0.7 M), temperature (30-50oC), the volume ratio of feed phase to membrane phase (200-400ml/80ml), agitation speed of the feed phase (75-125 rpm), membrane stirring speed (0, 100, 150 rpm), carrier concentration (1, 5, 9 wt%), the pH of feed (2, 4, 6, 8, 10), and solvent type (CCl4 and n-Heptane). The study shows that high extraction efficiency for ACTP of about 97% was achieved by a bulk liquid membrane at 50 ppm initial concentration of feed; stirring speed of feed phase 130 rpm; stirring speed of membrane phase 100rpm; 0.5 M NaCl concentration; carrier concentration 1wt%; volume ratio of 200ml feed:80ml membrane; feed pH of ACTP is 6,  and 50˚C. The transport kinetics was evaluated using a kinetic model with two consecutive first-order irreversible reactions. The kinetics of (ACTP) transport by bulk liquid membrane was investigated at the best experimental conditions. The activation energy values of the extraction and stripping processes were 1.733 and 1.826 kJ.mol−1. The activation energy confirms that the transport process from solutions is controlled by diffusion.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Determination of the Optimum Conditions for Removal of Congo Red Dye by Peroxidase Enzyme Plant
...Show More Authors

The pollution producing from textile industries effluents is growing since the years, due to at discharged lots of it in water without treatment. The resulting effluent is colourful, highly toxic, and poses a significant environmental hazard. This problem can be solved by using enzymic biological treatment, where the Congo red dye was used with concentrations (100,200,300,500) mg /L, pH values (3,4,5,6,7,8), and variable temperatures (25,35,45)°C, the best removal of Congo red (CR) dye  under optimum conditions for degradation was at  concentration of 100 mg/L, at (pH 6, 25 °C) with efficiency of 99.85 % using the peroxidase enzyme extracted from red radish plant, while the removal percentage decreased when increase dye concentration

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Modeling of Bending Properties of Stainless Steel 304 Sheets Welded by Tungsten Inert Gas Welding Process
...Show More Authors

In this research, the effects of both current and argon gas pressure on the bending properties of welded joints were studied. Using the possible ranges of welding gas pressures and currents, Tungsten inert gas welding (TIG) of stainless steel (304) sheet was used to obtain their influence on the maximum bending force of the (TIG) welded joints. Design of experiment (DOE) ‘version 10' was used to determine the design matrix of experiments depending on the used levels of the input factors. Response surface methodology (RSM) technique was used to obtain an empirical mathematical model for the maximum bending force as a function of welding parameters (Current and Argon gas pressure). Also, the analysis of variance (ANOVA) was used to verif

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrocoagulation of phenol for wastewater treatment
...Show More Authors

Electrocoagulation is an electrochemical process of treating polluted water where sacrificial anode corrodes to produce active coagulant (usually aluminum or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles). The present study investigates the removal of phenol from water by this method. A glass tank with 1 liter volume and two electrodes were used to perform the experiments. The electrode connected to a D.C. power supply. The effect of various factors on the removal of phenol (initial phenol concentration, electrode size, electrodes gab, current density, pH and treatment time) were studied. The results indicated that the removal efficiency decreased as initial phenol concentration

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2003
Journal Name
Turkish Journal Of Chemistry
Gas Chr Gas Chromatographic Separ aphic Separation of Phenol Deriv ation of Phenol Derivatives by Schiff- y SchiffBase Liquid Crystalline Stationary Phases
...Show More Authors

The chromatographic behaviour of liquid crystalline compounds benzylidene-p-aminobenzoic acid and 4-(p-methyl benzylidene)-p-aminobenzoic acid as stationary phases for the separation of dimethylphenol isomers was investigated. These isomers were analysed on benzylidene-p-aminobenzoic acid within a nematic range of 169-194 ◦C with a temperature interval of 5 ◦C. Better peak resolution was at a column temperature of 190 ◦C. The analysis was repeated on a 4-(p-methyl benzylidene)-p-aminobenzoic acid column at a nematic temperature of 256 ◦C, which represented the end of the nematic range, and gave the optimum peak resolution. It was found that isomer better separation was obtained at 20% loading for both liquid crystal materials. Other

... Show More
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effects of Operating Variables on Efficancy of Water Disinfection by Sodium Hypochlorite Using Al-Wathba Wastewater
...Show More Authors

The aim of this investigation was to study the impact of various reaction parameters on wastewater taken from Al-Wathba water treatment plant on Tigris River in south of Baghdad, Iraq with sodium hypochlorite solution. The parameters studied were sodium hypochlorite dose, contact time, initial fecal coliform bacteria concentration, temperature, and pH. In a batch reactor, different concentrations of sodium hypochlorite solution were used to disinfect 1L of water. The amount of hypochlorite ions in disinfected water was measured using an Iodimetry test for different reaction times, whereas the Most Probable Number (MPN) test was used to determine the concentration of coliform bacteria. Total Plate Count (TPC) was utilized in this study to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 10 2021
Journal Name
Neuroquantology
Direct Yellow 8 Azo Removal by Bentonite Clay Solution: Experimental and Theoretical Studies
...Show More Authors

In the theoretical part, removal of direct yellow 8 (DY8) from water solution was accomplished using Bentonite Clay as an adsorbent. Under batch adsorption, the adsorption was observed as a function of contact time, adsorbent dosage, pH, and temperature. The equilibrium data were fitted with the Langmuir and Freundlich adsorption models, and the linear regression coefficient R2 was used to determine the best fitting isotherm model. thermodynamic parameters of the ongoing adsorption mechanism, such as Gibb's free energy, enthalpy, and entropy, have also been measured. The batch method was also used for the kinetic calculations, and the day's adsorption assumes first-order rate kinetics. The kinetic studies also show that the intrapar

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Ecological Engineering
Dual Application of Al-Kheriat of Removal of Arsenic from Aqueous Solution and Acting as Rodenticide
...Show More Authors

Arsenic is a prevalent and pervasive environmental contaminant with varied amounts in drinking water. Arsenic exposure causes cancer, cardiovascular, liver, nerve, and ophthalmic diseases. The current study aimed to find the best conditions for eliminating arsenic from simulated wastewater and their effect on biomarkers of hepatic in mice. Adsorption tests including pH, contact duration, Al-kheriat dosage, and arsenic concentrations were evaluated. Seventy-two healthy albino mice (male) were accidentally allocated into nine groups (n = 8), the first group was considered as healthy control, the second group (AL-Kheriat), and other groups received AL-Kheriat and arsenic 25, 50, 75, 100, 125, 150 and 175 mg/kg, respectively. Next 10 days, the

... Show More
Crossref (3)
Crossref
Publication Date
Wed Sep 24 2014
Journal Name
International Journal Of Environmental Science And Technology
Removal of copper ions from contaminated groundwater using waste foundry sand as permeable reactive barrier
...Show More Authors

Scopus (18)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Alexandria Engineering Journal
Calcium/iron-layered double hydroxides-sodium alginate for removal of tetracycline antibiotic from aqueous solution
...Show More Authors

Crossref (45)
Crossref