This research presents a comparison of performance between recycled single stage and double stage hydrocyclones in separating water from water/kerosene emulsion. The comparison included several factors such as: inlet flow rate (3,5,7,9, and 11 L/min), water feed concentration (5% and 15% by volume), and split ratio (0.1 and 0.9). The comparison extended to include the recycle operation; once and twice recycles. The results showed that increasing flow rate as well as the split ratio enhancing the separation efficiency for the two modes of operation. On the contrary, reducing the feed concentration gave high efficiencies for the modes. The operation with two cycles was more efficient than one cycle. The maximum obtained efficiencies were 97% and 97.5% at 5% concentration, 11 L/min, and 0.9 split ratio for twice recycled single stage and double stage hydrocyclones, respectively. The pressure drop was the same for the two modes of operation. It was concluded that using recycled single stage hydrocyclone was more economical since it reduced the cost of additional hydrocyclone.
Abstract
The current research aims to clarify the role of local policies on the performance of the province of Baghdad, after studies proved practical experience what those policies of the major role and effect on the lives of citizens, as well as alleviate the burden on central government, which make a lot of states give local governments broad powers and her specialty funds for the exercise of its vital role and actor in various joints of local development, research has indentified a problem in a number of questions such as: do you have the policy of the provincial council of local qualified and able to influence the performance of the province? What are the main forces of powerful and implementation of policies at all
... Show MoreThe systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are Conventional within this atmosphere of Iraq, and after taking different readings
... Show MoreSome of the main challenges in developing an effective network-based intrusion detection system (IDS) include analyzing large network traffic volumes and realizing the decision boundaries between normal and abnormal behaviors. Deploying feature selection together with efficient classifiers in the detection system can overcome these problems. Feature selection finds the most relevant features, thus reduces the dimensionality and complexity to analyze the network traffic. Moreover, using the most relevant features to build the predictive model, reduces the complexity of the developed model, thus reducing the building classifier model time and consequently improves the detection performance. In this study, two different sets of select
... Show MoreThis research dealt with the process of reducing costs through some strategic methods of management accounting targeted cost analysis unassembled and Alkeisen, where he focused this research through his theory on a review of some administrative accounting strategic technologies, while the second practical side through the application of targeted cost analysis unassembled and Alkeisen, acquired Search importance of focusing on the decisions to cut costs, through the use of some administrative accounting strategic methods and this we can unassembled analysis, continuous improvement, and the cost of quality) when applied quality, "in light of this has been reached to a set of conclusions that the most important of the company's relian
... Show More