Preferred Language
Articles
/
ijcpe-782
Experimental Study for Assessment of Cutting Density Effect on Hole Cleaning Efficiency in Inclined and Horizontal Wells
...Show More Authors

The poor hole cleaning efficiency could causes many problems such as high torque, drag, poor hydraulics and pipe stuck. These inherent problems result in an avoidable high operation cost which this study tried to address.  In this study, the effect of cutting density on hole cleaning efficiency in deviated and horizontal wells was investigated. Experiments were conducted using 40 feet (12 m) long of flow loop made from iron and PVC. However, the test section was made from PVC with (5.1m) long and (4” ID) for outer pipe and (2” OD) inner pipe. The cutting transport ratio (CTR) was determined from weight measurements for each test. Cutting Transport Ratio has been investigated for effects of the following parameters; flow rate, cutting size and density, yield point of drilling mud, and inclination angle. Once the setup was positioned at the desired inclination, the cutting was transported for 3 minutes at a constant flow rate and yield point. The amount of cutting removed during each test was thereafter weighted to determine cutting transport ratio CTR.

The results obtained from this study showed that the cutting density has a slight to moderate effect on hole cleaning efficiency. Also, there was a remarkable improvement in the cutting transport ratio annular velocity and hole inclination angle was increased. However, the yield point (Yp) was negligible at maximum values of annular velocity. Therefore, at high value of yield point the cuttings with large and medium size were transported more than small size. This case is inversed at a low value of Yp. Moreover, for all sizes the heavy cutting transport less than light cutting. Finally, the critical angle was recorded between 65o-75o. Sigma plot 12.5 program has been used to graph all figures in this paper.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 28 2016
Journal Name
Separation Science And Technology
Using sewage sludge as a permeable reactive barrier for remediation of groundwater contaminated with lead and phenol
...Show More Authors

Scopus (24)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Petroleum And Coal
Evaluation of geomechanical properties for tight reservoir using uniaxial compressive test, ultrasonic test, and well logs data
...Show More Authors

Scopus (9)
Scopus
Publication Date
Sat Feb 27 2021
Journal Name
Journal Of Engineering
Design and Simulation of a controller for Double Fed Induction Generator turbine Utilized Solar Up Draft Tower
...Show More Authors

This paper introduces a complete design and simulation of a controller for the double fed induction generator (DFIG) turbine. The work also included the solar updraft tower (SUT) design to supply Al-Mahmoudia hospital in Baghdad/Iraq. The design includes the daily average load estimation, annual solar irradiance and, temperature monitoring, and logging.

According to the data obtained from the Ministry of Science and Technology, Baghdad has low wind speed. Therefore, the (SUT) has been designed to generate electrical power depending on the difference between the external and internal air temperature. The temperature difference will generate a suitable airspeed to drive the wind turbine, connected to the proposed (DFIG) generators

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Journal Of Ecological Engineering
Date Palm Fibre Waste Exploitation for the Adsorption of Congo Redis Dye via Batch and Continuous Modes
...Show More Authors

The present study utilised date palm fibre (DPF) waste residues to adsorb Congo red (CR) dye from aqueous solutions. The features of the adsorbent, such as its surface shape, pore size, and chemical properties, were assessed with X-ray diffraction (XRD), BET, Fourier-transform infrared (FTIR), X-ray fluorescence (XRF), and field emission scanning electron microscope (FESEM). The current study employed the batch system to investigate the ideal pH to adsorb the CR dye and found that acidic pH decolourised the dye best. Extending the dye-DPF waste mixing period at 25°C reportedly removed more dye. Consequently, the influence of the starting dye and DPF waste quantity on dye removal was explored in this study. At 5 g/L dye concentration, 48% d

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2025
Journal Name
International Journal Of Hydrogen Energy
A comprehensive review of battery thermal management systems for electric vehicles: Enhancing performance, sustainability, and future trends
...Show More Authors

View Publication
Scopus (41)
Crossref (53)
Scopus Clarivate Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Baghdad Science Journal
Simultaneous spectrophotometric method for determination of both ciprofloxacin and cephalexin by using H-point standard addition method
...Show More Authors

طريقة سهلة وبسيطة ودقيقة لتقدير السبروفلوكساسين  في وجود السيفاليكسين او العكس بالعكس في خليط منهما. طبقت الطريقة المقترحة بطريقة الاضافة القياسية لنقطة بنجاح في تقدير السبروفلوكساسين بوجود السيفاليكسين كمتداخل عند الاطوال الموجية 240-272.3 نانوميتر وبتراكيز مختلفة من  السبروفلوكساسين 4-18 مايكروغرام . مل-1 وكذلك تقدير السيفاليكسين بوجود السبروفلوكساسين الذي يتداخل باطوال موجية 262-285.7 نانوميتر وبتراكيز مخ

... Show More
View Publication
Scopus (5)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Sep 20 2023
Journal Name
Environmental Progress & Sustainable Energy
Production and characterization of composite activated carbon from potato peel waste for cyanide removal from aqueous solution
...Show More Authors
Abstract<p>This research presents a response surface methodology (RSM) with I‐optimal method of DESIGN EXPERT (version 13 Stat‐Ease) for optimization and analysis of the adsorption process of the cyanide from aqueous solution by activated carbon (AC) and composite activated carbon (CuO/AC) produced by pyro carbonic acid microwave using potato peel waste as raw material. Pyrophosphate 60% (wt) was used for impregnation with an impregnation ratio 3:1, impregnation time of 4 h at 25°C, radiant power of 700 W, and activation time of 20 min. Batch experiments were conducted to determine the removal efficiency of cyanide from aqueous solution to evaluate the influences of various experimental parameters su</p> ... Show More
View Publication
Scopus (9)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Mar 07 2017
Journal Name
Journal Of Pharmacy And Pharmacology
Personalised dosing of medicines for children
...Show More Authors
Abstract<sec><title>Objectives

Doses for most drugs are determined from population-level information, resulting in a standard ?one-size-fits-all’ dose range for all individuals. This review explores how doses can be personalised through the use of the individuals’ pharmacokinetic (PK)-pharmacodynamic (PD) profile, its particular application in children, and therapy areas where such approaches have made inroads.

Key findings

The Bayesian forecasting approach, based on population PK/PD models that account for variability in exposure and response, is a potent method for personalising drug therapy. Its potential utility is eve

... Show More
View Publication
Scopus (32)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Wed Jun 30 2021
Journal Name
College Of Islamic Sciences
Methodological fundations for narrators of Sunan
...Show More Authors

بحث لمعرفة رواة السنن والمسانيد للحافظ ابن نقطة

 

View Publication Preview PDF
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrocoagulation of phenol for wastewater treatment
...Show More Authors

Electrocoagulation is an electrochemical process of treating polluted water where sacrificial anode corrodes to produce active coagulant (usually aluminum or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles). The present study investigates the removal of phenol from water by this method. A glass tank with 1 liter volume and two electrodes were used to perform the experiments. The electrode connected to a D.C. power supply. The effect of various factors on the removal of phenol (initial phenol concentration, electrode size, electrodes gab, current density, pH and treatment time) were studied. The results indicated that the removal efficiency decreased as initial phenol concentration

... Show More
View Publication Preview PDF