Corrosion rate tests were carried out on carbon steel under concentration cells conditions of oxygen and sodium chloride. The effect of aeration in one compartment on the corrosion rate of both coupled metals was determined. In addition, the effects of time and temperatures on the corrosion rate of both coupled metals and galvanic currents between them were investigated. Corrosion potentials for the whole range of operating conditions under concentration cell conditions were also studied. The results showed that under aeration condition, the formation of concentration cell caused a considerable corrosion rate of the Carbon steel specimens coupled in different concentrations of O2 and NaCl due to the galvanic effect. Aerating one compartment caused a noticeable increase in the corrosion rate of the coupled specimen in the other compartment due to the galvanic effect. Increasing temperature caused unstable trends in the free and galvanic corrosion potentials. Increasing the temperature led to an increase in the corrosion rate for both metals.
Corrosion inhibiting admixtures are unique among other methods to protect reinforced concrete from corrosion damage. In this study, the effect of furfural on the fresh and hardened properties of concrete mixes of 35 and 45 MPa compressive strengths as well as the corrosion inhibition of furfural was evaluated. Furfural was added at different dosages (1, 2 and 3% by weight of cement) with and without superplasticizer (HRWR). Different electrochemical measurements were performed (Half-cell potential, Tafel plot and linear polarization resistance). Electrochemical measurements confirmed that furfural dramatically reduces the rate of corrosion; the inhibition efficiencies were 62.7 and 63.8 % due to 3% furfural addition to 35 and 45MPa-concr
... Show MoreLight naphtha one of the products from distillation column in oil refineries used as feedstock for gasoline production. The major constituents of light naphtha are (Normal Paraffin, Isoparaffin, Naphthene, and Aromatic). In this paper, we used zeolite (5A) with uniform pores size (5Aº) to separate normal paraffin from light naphtha, due to suitable pore size for this process and compare the behavior of adsorption with activated carbon which has a wide range of pores size (micropores and mesopores) and high surface area. The process is done in a continuous system - Fixed bed reactor- at the vapor phase with the constant conditions of flow rate 5 ml/min, temperature 180oC, pressure 1.6 bar and 100-gram weight o
... Show MoreIn the present study, MIG welding is carried out on low carbon steel type (AISI 1015) by using electrode ER308L of 1.5mm diameter with direct current straight polarity (DCSP). The joint geometry is of a single V-butt joint with one pass welding stroke for different plate thicknesses of 6, 8, and 10 mm. In welding experiments, AISI 1015 plates with dimensions of 200×100mm and edge angle of 60o from both sides are utilized. In this work, three main parameters related to MIG welding process are investigated, which are welding current, welding speed, heat input and plate thickness, and to achieve that three groups of plates are employed each one consists of three plates. The results indicate that increasing the weld heat input (t
... Show MoreIn this work, calcium ions were determined by the addition to the allyl chloride monomer resulting from bulk polymerization formation. To acquire the highest adsorption capacity, molar ratios of the template, monomer, and cross-linking agent, as well as solvents and multiple monomers were investigated. Scanning Electron Microscopy (SEM) and Fourier Transform Infrared Spectroscopy (FTIR) were used to analyze the calcium ion polymer. The elution of calcium had a small effect on the surfaces of the three-dimensional network structure. Calcium (II) ions were successfully eluted using a mixture of methanol and acetic acid. The calcium adsorption capacities were 3.8145 and 9.01773 mol/g (Qmax), respectively. A Langmuir isot
... Show MoreIn this study, concentrations of radon and uranium were measured for twenty six samples of soil. The radon concentrations in soil samples measured by registrant alpha-emitting radon (222Rn) by using CR-39 track detector. The uranium concentrations in soil samples measured by using registrar fission fragments tracks in CR-39 track detector that caused by the bombardment of U with thermal neutrons from 241 Am-Be neutron source that has flux of 5 ×103n cm-2 s-1.
The concentrations values were calculated by a comparison with standard samples The results show that the radon concentrations are between (91.931-30.645Bq/m3).
The results show that also the uranium concentrat
This research is dealing with five sample of tomato ketchup products available in local market that were respectively as follows: Hello-Baghdad Iraq, Tiffany-Abu Dhabi, Melody-Dubai, Baidar-Saudi Arabia, and Altunsa-Turkey. Also it is dealing with four sample of sauce products available in local market that were respectively as follows: Hello-Baghdad, Iraq, Al-Badawi-Baghdad Iraq, Family-Baghdad, Iraq, and Hala-Amman Jordon. Analysis was performed on each sample three times and mean of the reading was taking. Samples were tested through terse and shorthand from lengthened steps. The spectrophotometric method used rely on theoretical and practical bases in extraction and diagnosis by UV spectrophotometer. This method in short notes, consiste
... Show MoreThe current study was applied in Al-Zafaraniya area southeast of the capital Baghdad from October 2021 to April 2022. This is to evaluate some heavy elements (Cd, Co, Cu, Fe, Pb, and Mn) in the street, storm, and suspended dust. Four sampling sites were selected, and codes A, B, C, and D were given to represent the industrial activity sites, service workshops, business activity, and residential areas.
The results showed that the concentration rates of elements (Cd, Co, Cu, Fe, Pb, Mn) in street dust samples were (1.15, 6.6, 60.15, 26770, 44.4, 6, 489.8). In storm dust (2, 10, 49.3, 54760, 24.3, 827.2) ppm, respectively, the results of suspended dust revealed that the general rates of element concentrations were (0.7
... Show MoreThis paper reports a.c., d.c. conductivity and dielectric behavior of Ep-hybrid composite with12 Vol.% Kevlar-Carbon hybrid . D.C. conductivity measurements are conducted on the graded composites by using an electrometer over the temperature range from (293-413) K. It was shown then that conductivity increases by increasing number of Kevlar –Carbon fiber layers (Ep1, Ep2, Ep3), due to the high electrical conductivity of Carbon fiber. To identify the mechanism governing the conduction, the activation energies at low temperature region (LTR) and at high temperature region (HTR) have been calculated. The activation energy values for hybrid composite decrease with increasing number of fiber layers. The a.c. conductivity was measured over fr
... Show More