In this study, the effects of blending the un-branched acrylate polymer known as Poly (n-decyl acrylate), and the branched acrylate polymer known as Poly (iso-octyl acrylate), on the viscosity index (VI), and the pour point of the Iraqi base stocks 40, and 60 respectively, were investigated. Toluene was used as a carrier solvent for both polymer types. The improvement level of oils (VI, & pour point) gained by blending the oil with the acrylate derived polymers was compared with the values of (VI, and pour point) gained by blending the oil with a commercial viscosity index, and pour point improver. The commercial lubricant additive was purchased and used by Al-Daura Refineries. It consisted of an un-known olefin copolymer dissolved in an un-known carrier solvent. All polyacrylate derivatives and the commercial lubricant additive named HITEC5748 were blended with each type of oil in weight percentage of (2, 4, 6, 8, & 10) wt. %. The result of the study was that the improvement in the viscosity index and the pour point of both base stock types was higher when using the polyacrylate derivatives than when using the commercial olefin copolymer additive.
Hypertension is one of the leading causes of the global burden of disease, which causes serious health problems. The aim of this study is to investigate the lipid profile levels in sera of Iraqi hypertensive patients by measuring Total cholesterol (TC), triglyceride (TG) and low density lipoproteins (LDL) and kidney function levels by measuring uric acid, urea and creatinine. Seventy five individuals of Iraqi adults (Males) were divided into three groups: 25 hypertensive patients with duration of disease (1-10) year (group 1), 25 hypertensive patients with duration of disease (11-30) year (group 2) and 25 normal individuals as control group (group3). The findings indicate that serum (TC, TG and LDL) levels were significantly elevated (
... Show MoreWell integrity is a vital feature that should be upheld into the lifespan of the well, and one constituent of which casing, necessity to be capable to endure all the interior and outside loads. The casing, through its two basic essentials: casing design and casing depth adjustment, are fundamental to a unique wellbore that plays an important role in well integrity. Casing set depths are determined based on fracturing pressure and pore pressure in the well and can usually be obtained from well-specific information. Based on the analyzes using the improved techniques in this study, the following special proposition can be projected: The selection of the first class and materials must be done correctly and accurately in accordance with
... Show MoreWell integrity is a vital feature that should be upheld into the lifespan of the well, and one constituent of which casing, necessity to be capable to endure all the interior and outside loads. The casing, through its two basic essentials: casing design and casing depth adjustment, are fundamental to a unique wellbore that plays an important role in well integrity. Casing set depths are determined based on fracturing pressure and pore pressure in the well and can usually be obtained from well-specific information. Based on the analyzes using the improved techniques in this study, the following special proposition can be projected: The selection of the first class and materials must be done correctly and accurately in accordance with the
... Show MoreBackground: periodontitis is a chronic inflammatory disease causing destruction of the tooth supporting structures, initiated by dental plaque and modified by environmental and genetic risk factors. Cyclooxygenase-2 (COX-2) enzyme is responsible for the production of prostaglandin E2, an important mediator in the chronic periodontitis (CP) pathogenesis. Polymorphisms in COX-2 gene have linked to CP in different populations. Aim: To study the association between Cyclooxygenase-2 single nucleotide polymorphism rs689466 (-1195A/G SNP) and chronic periodontitis in a sample of Iraqi population. Methods: One hundred Iraqi subjects divided into two groups: case group consisted of 70 CP patient (35 males and 35 females) with age range 30-55 year
... Show MoreUrine proteomics have been an area of interest and recently in Kala-azar as an alternative sample type for serum or plasma. Because of simplicity, noninvasiveness of collection and simpler matrix. Many studies had detected an increased protein excretion in the urine of patients with active Kala-azar due to renal involvement particularly by an immunological related mechanism(s). This study have demonstrated the presence of three different protein profiles in Iraqi children (Patients: including 60 children aged 4-60 months) with defined Kala-azar using the conventional SDS-PAGE on urine samples. Urine protein profile in Kala-azar patients revealed three groups of banding patterns: group-1(33.4)% of the patients show the pattern of 5
... Show MoreThe paper include study the effect thickness of the polymeric sample which is manufactured by thermo press way. The sample was used as an active tunable R6G laser media. The remarks show that, when the thickness of the samples is increased, with the same concentration, the spectrum will shift towards the short wavelength, & the quantum fluorescence yield will increased. The best result we obtained for the quantum fluorescence yield is (0.68) at the sample, with thickness (0.304mm) in Ethanol solvent, while when we used the Pure Water as a solvent, we found that the best quantum fluorescence yield is (0.63) at (0.18mm) thickness of the sample.
The paper include studies the effect of solvent of dye doped in polymeric laser sample which manufactured in primo press way, which is used as an active (R6G) tunable dye lasers. The remarks show that, when the viscosity of the solvent (from Pure Water to Ethanol), for the same concentration and thickness of the performance polymeric sample is increased, the absorption spectrum is shifts towards the long wave length (red shift), & towards short wave length (blue shift) for fluorescence spectrum, also increased the quantum fluorescence yield. The best result we obtained for the quantum fluorescence yield is (0.882) with thickness (0.25mm) in Ethanol solvent in concentration (2*10-3mole/liter), while when we used the Pure Water as a solvent,
... Show MoreMany extracted material were used as mouthwash to settle different kinds of oral fungi and bacteria. In this study an extractive of Cyperus rotundus plant E.C.R. which is very active as a mouthwash, was used in concentration range (10-25) ppm in artificial saliva at pH=6.4 and temperature range (288-318) K, to study it’s inhibitory effect on the corrosion of dental amalgam. Potentiostatic and cyclic polarization were used to follow this study. The presence of E.C.R. lead to shift the corrosion potential to the active direction and decreased the corrosion rate to about 98.87%, the inhibition action of E.C.R. resulting from the adsorption of C.R.E. layer between amalgam and saliva as FTIR spectrums shows, where the variety of FTIR adsorptio
... Show MoreRheumatoid arthritis (RA) is a chronic inflammatory disease associated with decreased antioxidant state .This study aim to investigate the status of oxidant/antioxidant in a sample of Iraqi patients with RA and the role of peroxynitrite and its natural scavenger uric acid in them .This case-controlled study was conducted at Baghdad teaching hospital /Baghdad from December 2010-May 2011 . Twenty-five patients with mean age 39 years and 25 apparently healthy subject as controls with mean age 29 years were included in the study .Investigations include estimation of serum levels of nitric oxide (NO) ,peroxynitrite (PN) , malondialdehyde (MDA) , and uric acid (UA) .Serum PN levels were significantly elevated in RA patients a
... Show MoreIt has been shown in ionospheric research that calculation of the total electron content (TEC) is an important factor in global navigation system. In this study, TEC calculation was performed over Baghdad city, Iraq, using a combination of two numerical methods called composite Simpson and composite Trapezoidal methods. TEC was calculated using the line integral of the electron density derived from the International reference ionosphere IRI2012 and NeQuick2 models from 70 to 2000 km above the earth surface. The hour of the day and the day number of the year, R12, were chosen as inputs for the calculation techniques to take into account latitudinal, diurnal and seasonal variation of TEC. The results of latitudinal variation of TE
... Show More