Controlling cost in construction projects is an essential issue. This study investigates the most critical problems that cause weakness in cost control in Iraqi construction projects. The quantitative technique was used by conducting a survey directed to professionals who work on construction projects. One hundred and sixty-four questionnaire forms were distributed to private sector companies, government companies, and government institutions, and the responses were subjected to the required statistical analysis. The results indicate that the most influential factors are the weakness in keeping up with the use of modern concepts, methods, and technologies, the delay in receiving the amounts due for work done from the owner, fluctuat
... Show MoreAbstract
Robust controller design requires a proper definition of uncertainty bounds. These uncertainty bounds are commonly selected randomly and conservatively for certain stability, without regard for controller performance. This issue becomes critically important for multivariable systems with high nonlinearities, as in Active Magnetic Bearings (AMB) System. Flexibility and advanced learning abilities of intelligent techniques make them appealing for uncertainty estimation. The aim of this paper is to describe the development of robust H2/H∞ controller for AMB based on intelligent estimation of uncertainty bounds using Adaptive Neuro Fuzzy Inference System (ANFIS). Simulatio
... Show MoreThe current research aims to verify the relationship and impact of internal control activities as an independent variable in its dimensions (efficiency, training, independence) in making administrative decisions as a responsive variable and its dimensions (identifying and diagnosing the problem, searching for alternatives, evaluating alternatives, choosing the appropriate alternative, implementing the decision, following up Decision and evaluation) in the Kirkuk Water Directorate, as well as to identify the levels of their practices, and then try to come up with a number of recommendations contribute to the strengthening of internal control activities and the process of making administrative decisions of the researched Directorat
... Show MoreIn this article, a continuous terminal sliding mode control algorithm is proposed for servo motor systems. A novel full-order terminal sliding mode surface is proposed based on the bilimit homogeneous property, such that the sliding motion is finite-time stable independent of the system’s initial condition. A new continuous terminal sliding mode control algorithm is proposed to guarantee that the system states reach the sliding surface in finitetime. Not only the robustness is guaranteed by the proposed controller but also the continuity makes the control algorithm more suitable for the servo mechanical systems. Finally, a numerical example is presented to depict the advantages of the proposed control algorithm. An application in the rota
... Show MoreThis paper represents an experimental study on the application of smart control represented by the use of the fuzzy logic controller. Two-link flexible manipulators that are used in airspace and military applications are made of flexible materials characterized by low frequency and damping ratio. To solve this problem, this paper proposes the use of smart materials (piezoelectric transducers), where each link is bonded with a pair of piezoelectric transducers that act as a sensor and another as an actuator. As the arm vibrates because of the movement generated by the motor, this voltage is controlled by a regulator inside the LABVIEW® 2020 software and sends the output control voltage to the piezoelectric actuator. Experimental results
... Show MoreMany of mechanical systems are exposed to undesired vibrations, so designing an active vibration control (AVC) system is important in engineering decisions to reduce this vibration. Smart structure technology is used for vibration reduction. Therefore, the cantilever beam is embedded by a piezoelectric (PZT) as an actuator. The optimal LQR controller is designed that reduce the vibration of the smart beam by using a PZT element.
In this study the main part is to change the length of the aluminum cantilever beam, so keep the control gains, the excitation, the actuation voltage, and mechanical properties of the aluminum beam for each length of the smart cantilever beam and observe the behavior and effec
... Show MoreType 2 daibetes mellitus (T2DM) is a global concern boosted by both population growth and ageing, the majority of affected people are aged between (40- 59 year). The objective of this research was to estimate the impact of age and gender on glycaemic control parameters: Fasting blood glucose (FBC), glycated hemoglobin (HbA1C), insulin, insulin resistance (IR) and insulin sensitivity (IS), renal function parameters: urea, creatinine and oxidative stress parameters: total antioxidant capacity (TAC) and reactive oxygen species (ROS). Eighty-one random samples of T2DM patients (35 men and 46 women) were included in this study, their average age was 52.75±9.63 year. Current study found that FBG, HbA1C and IR were highly significant (P<0.01) inc
... Show MoreThe goal of the research is to find the optimization in the test of the appropriate cross-over design for the experiment that the researcher is carrying out (under assumption that there are carry-over effects of the treatments) to posterior periods after the application period (which is often assumed to be the first period). The comparison between the double cross-over design and the cross-over design with extra period. The similarities and differences between the two designs were studied by measuring the Relative Efficiency (RE) of the experiment.
The study addressed the change in the nature of the land cover of the Al-Jadriya Twist area for the period from 1976-2024 with an area of (140 km2)and for a period of (48 years) based on satellite images and their analysis using geographic information systems. The main classifications of the area were reached (water cover, residential areas, vegetation cover, in addition to empty, unused areas). The extracted data indicate a decrease in the water cover and the change rate reached (-14.29) and the residential areas increased with a change rate of (28.26), while the vegetation cover rate was recorded from (45 km2) to (66 km2) and the empty areas had a change rate of (-78.57).