A simple, accurate and sensitive spectrophotometric method for the determinaion of epinephrine is described . The method is based on the coordination of Pr (III) with epinephrine at pH 6. Absorbance of the resulting orange yellow complex is measured at 482 nm . A graph of absorbance versus concentrations shows that beer 's low is obeyed over the concentration range (1-50)mg.ml-1 of epinephrine with molar absorpitivity of ( 2.180x103 L.mol-1.cm-1 ), a sandell sensitivity of (0.084 mg.cm-2 ), a relative error of (-2.83%) , a corrolation coffecient (r= 0.9989) and recovery % ( 97.03 ± 0.75 ) depending on the concentration.This method is applied to analyse EP in several commercially available pharmaceutical preparations
... Show MoreThis research involves an indirect Fluorophotometric method for the determination of microgram amount of oxymetazoline hydrochloride in the concentration range 0.1-5.0 g/ml. The method is based on the oxidation of the drug by cerium sulphate solution which is acidic medium where Ce IV is reduced to Ce III which can be excited at 259 nm to give an emitted light at 377 nm which is directly proportional to the concentration of Ce III which is equivalent to Ce IV that is needed to oxidize the studied drug. The average recovery of the method is 100.19% and relative standard deviation (RSD) < 0.37% . The method have been successfully applied to the determination of the studied drug in its pure and pharmaceutical preparations and it wa
... Show MoreAn accurate and sensitive spectrophotometric method has been developed for the determination of cefotaxime (CEF) in pure and pharmaceutical samples. The suggested method depended on the coupling reaction between diazotized cefotaxime and 3,5-dimethyl phenol (3,5-DMPH) in basic medium to form light orange, water soluble dye, that is stable and has a maximum absorbance at 497nm. The calibration graph was liner over the concentration range (1-70) µg.mL-1 with LOD of 0.750 µg.mL-1 and LOQ of. 2.740 µg. mL-1, sandal sensitivity of 0.0526 µg. cm-2 . molar absorptivity 11328 Lmol-1 cm-1 . The stoichiometry composition was found by Jobs a
... Show MoreA simple, accurate and sensitive spectrophotometric method for the determination of Procaine penicillin (PP) is described. The method is based on charge-transfer reaction of PP with metol (N-methyl-p-hydroxy aniline) in the presence of ferric sulphate to form a purple-water soluble complex ,which is stable and has a maximum absorption at 510 nm .A graph of absorbance versus concentration shows that Beer’s low is obeyed over the concentration range of 3-80 µg /ml of PP (i.e.,3-80 ppm) with a molar absorbativity of 4.945 ×103 L.mol-1.cm-1 ,Sandell sensitivity of 0.1190 µg cm-2 ,a relative error of (-1.57)-2.79 % and a standard deviation of less than 0.59 depending on the concentration of PP.The optimum conditions for full co
... Show MoreThis work demonstrates the synthesis and storage of molecular-imprinted polymers (MIP) at room temperature using bulk polymerisation of Metformin (Met) characterized by high sensitivity, low cost, and high stability. To ensure an acceptable adsorption capacity, the research employed 0.8:4:20 mmol ratios of template, monomer, and cross-linking agents for the polymerization. A functional monomer, 2-acrylamido-2-methyl-1-propane sulphonic acid C7H13NO4S, was cross-linked with N,N-methylene bisacrylamide C7H10N2O2 to form Met-MIP, which could be characterized using a UV-VIS spectrophotometer at 236 nm, FT-IR spectroscopy, and scanning electron
... Show MoreFor the determination of metoclopramide hydrochloride (MCPD) in pharmaceutical formulations, a rapid and straightforward spectrophotometric method has been proposed. The method involves diazotizing the main amino group of MCPD with sodium nitrite followed by coupling reaction with reagent 1,7-Dihydroxynaphthalene (1,7-DHN) to form a stable and colored compound in alkaline medium of sodium hydroxide which showed a maximum absorbance intensity at the wavelength 578 nm. The linearity of developed method has ranged from 1.0 - 15 µg.ml-1 while the molar absorptivity 2.9867x104 l.mol-1.cm-1, RSD% was less than 1.11%. While the LOD and LOQ were 0.059 µg.ml-1
... Show MoreA simple, cheap, fast, accurate, Safety and sensitive spectrophotometric method for the determination of sulfamethaxazole (SFMx), in pure form and pharmaceutical dosage forms. has been described The Method is based on the diazotization of the drug by sodium nitrite in acidic medium at 5Cº followed by coupling with salbutamol sulphate (SBS) drug to form orange color the product was stabilized and measured at 452 nm Beer’s law is obeyed in the concentration range of 2.5-87.5 ?g ml-1 with molar absorptivity of 2.5x104 L mole-1 cm-1. All variables including the reagent concentration, reaction time, color stability period, and sulfamethaxazole /salbutamol ratio were studied in order to optimize the reaction conditions. No interferences were
... Show MoreEnvironmental pollution is one of the world's biggest problems, and plant waste is one of its causes. For this reason, we have tried in this work to take advantage of this waste and benefit from it instead of being one of the pollutants. Seven dry waste from different plants (bitter orange peels, pomegranate peels, bitter orange leaves, Ziziphus leaves, albizia leaves, waste of black tea, and zahidi date palm fibers) were tested as cheap source of melatonin )MLT), which is a very important indoleamine compound. Throughout the current study, this hormone was extracted from these plants’ waste (which are considered as environmental pollutants) by applying different modified methods, whereby melatonin was identified and quantified by the
... Show MoreA nonlinear filter for smoothing color and gray images
corrupted by Gaussian noise is presented in this paper. The proposed
filter designed to reduce the noise in the R,G, and B bands of the
color images and preserving the edges. This filter applied in order to
prepare images for further processing such as edge detection and
image segmentation.
The results of computer simulations show that the proposed
filter gave satisfactory results when compared with the results of
conventional filters such as Gaussian low pass filter and median filter
by using Cross Correlation Coefficient (ccc) criteria.