Preferred Language
Articles
/
ijcpe-645
Modeling and Simulation of a Fire Tube Boiler
...Show More Authors

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Simulation and evaluation of elliptical hyperboloid solar concentrator by using Zemax program
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Wed Nov 03 2021
Journal Name
International Journal Of Energy Research
Simulation and experimentation study on the performance of metal hydride storage vessels
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2022
Journal Name
International Journal Of Engineering Transactions C: Aspects
Axial Behavior of Concrete Filled-steel Tube Columns Reinforced with Steel Fibers
...Show More Authors

Concrete filled steel tube (CFST) columns are being popular in civil engineering due to their superior structural characteristics. This paper investigates enhancement in axial behavior of CFST columns by adding steel fibers to plain concrete that infill steel tubes. Four specimens were prepared: two square columns (100*100 mm) and two circular columns (100 mm in diameter). All columns were 60 cm in length. Plain concrete mix and concrete reinforced with steel fibers were used to infill steel tube columns. Ultimate axial load capacity, ductility and failure mode are discussed in this study. The results showed that the ultimate axial load capacity of CFST columns reinforced with steel fibers increased by 28% and 20 % for circular and square c

... Show More
Scopus (6)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL INVESTIGATION OF INDIVIDUAL EVACUATED TUBE HEAT PIPE SOLAR WATER HEATING SYSTEMS
...Show More Authors

lar water heating systems with heat pipes of three diameter groups of 16, 22 and 28.5 mm. The first and third groups had evaporator lengths of 1150, 1300 and 1550 mm. The second group had an additional length of 1800 mm. all heat pipes were of fixed condenser length of 200 mm. Ethanol at 50% fill charge ratio of the evaporator volume was used as the heat pipes working fluid. Each heat pipe condenser section was inserted in a storage tank and the evaporator section inserted into an evacuated glass tube of the Owens- Illinois type. The combined heat pipe and evacuated glass tube form an active solar collector of a unique design.
The resulting ten solar water heating systems were tested outdoors under the meteorological conditions of Bag

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Case Studies In Thermal Engineering
Robust composite temperature control of electrical tube furnaces by using disturbance observer
...Show More Authors

As one type of resistance furnace, the electrical tube furnace (ETF) typically experiences input noise, measurement noise, system uncertainties, unmodeled dynamics and external disturbances, which significantly degrade its temperature control performance. To provide precise, and robust temperature tracking performance for the ETF, a robust composite control (RCC) method is proposed in this paper. The overall RCC method consists of four elements: First, the mathematical model of the ETF system is deduced, then a state feedback control (SFC) is constructed. Third, a novel disturbance observer (DO) is designed to estimate the lumped disturbance with one observer parameter. Moreover, the stability of the closed loop system including controller

... Show More
View Publication
Scopus (11)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Journal Of Engineering
Modeling of Comparative Performance of Asphalt Concrete under Hammer, Gyratory, and Roller Compaction
...Show More Authors

The main objective of this study is to develop predictive models using SPSS software (version 18) for Marshall Test results of asphalt mixtures compacted by Hammer, Gyratory, and Roller compaction. Bulk density of (2.351) gm/cc, at OAC of (4.7) % was obtained as a benchmark after using Marshall Compactor as laboratory compactive effort with 75-blows. Same density was achieved by Roller and Gyratory Compactors using its mix designed methods.

A total of (75) specimens, for Marshall, Gyratory, and Roller Compactors have been prepared, based on OAC of (4.7) % with an additional asphalt contents of more and less than (0.5) % from the optimum value. All specimens have been subjected to Marshall Test. Mathematical model

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 10 2017
Journal Name
Al-academy
cognitive references of the directorial imagination and modeling of the theatrical actor performance
...Show More Authors

This research is determined by the study of  the " cognitive references of the directorial imagination and modeling of  the theatrical actor performance ." it has described an Iraqi theatrical model, The research began with the great importance of the director's imagination as the basic premise for crystallizing the  director's vision according to its cognitive references in creating a solid performance model based on the aesthetic, intellectual and technical bases, It is also contributes to the formation of the theatrical show as a technical framework that presents the show in one unified fabric.

The research sought to reach through the problem of research, which is in the question of: What is the modeling of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Simulation and Experimental Investigation of Performance and Flow Behavior for Steam Ejector Refrigeration System
...Show More Authors

The ejector refrigeration system is a desirable choice to reduce energy consumption. A Computational Fluid Dynamics CFD simulation using the ANSYS package was performed to investigate the flow inside the ejector and determine the performance of a small-scale steam ejector. The experimental results showed that at the nozzle throat diameter of 2.6 mm and the evaporator temperature of 10oC, increasing boiler temperature from 110oC to 140oC decreases the entrainment ratio by 66.25%. At the boiler temperature of 120oC, increasing the evaporator temperature from 7.5 to 15 oC increases the entrainment ratio by 65.57%. While at the boiler temperature of 120oC and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Mar 31 2013
Journal Name
Inventi Impact: Artificial Intelligence
SIMULATION OF IDENTIFICATION AND CONTROL OF SCARA ROBOT USING MODIFIED RECURRENT NEURAL NETWORKS
...Show More Authors

This paper presents a modified training method for Recurrent Neural Networks. This method depends on the Non linear Auto Regressive (NARX) model with Modified Wavelet Function as activation function (MSLOG) in the hidden layer. The modified model is known as Modified Recurrent Neural (MRN). It is used for identification Forward dynamics of four Degrees of Freedom (4-DOF) Selective Compliance Assembly Robot Arm (SCARA) manipulator robot. This model is also used in the design of Direct Inverse Control (DIC). This method is compared with Recurrent Neural Networks that used Sigmoid activation function (RS) in the hidden layer and Recurrent Neural Networks with Wavelet activation function (RW). Simulation results shows that the MRN model is bett

... Show More
View Publication
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Design and Simulation of L1-Adaptive Controller for Position Control of DC Servomotor
...Show More Authors

This paper presents L1-adaptive controller for controlling uncertain parameters and time-varying unknown parameters to control the position of a DC servomotor. For the purpose of comparison, the effectiveness of L1-adaptive controller for position control of studied servomotor has been examined and compared with another adaptive controller; Model Reference Adaptive Controller (MRAC). Robustness of both L1-adaptive controller and model reference adaptive controller to different input reference signals and different structures of uncertainty were studied. Three different types of input signals are taken into account; ramp, step and sinusoidal. The L1-adaptive controller ensured uniformly bounded

... Show More
View Publication Preview PDF