Preferred Language
Articles
/
ijcpe-584
Study the Characteristic Performance of Trickling Filter for Pharmaceutical Waste Treatment
...Show More Authors

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Environmental pollution of solid waste and methods of managing it Study in Ramadi Municipality Case
...Show More Authors

The current research aims at finding out how to properly and correctly manage waste and solid waste and reduce the difficulties faced by all countries. However, it is becoming increasingly acute in developed cities because their economies are growing rapidly. It is necessary to identify the modern methods used in developed countries in managing wastes. The use of modern waste management techniques is a coordinated effort by international agencies within the borders responsible for them. The problem of the study can be identified in the lack of clarity of environmental management procedures in place. The importance of the research contributes to providing greater capacity to the administrative and technical leadership in the municipality

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Journal Of Engineering
Study of Using of Recycled Brick Waste (RBW) to produce Environmental Friendly Concrete: A Review
...Show More Authors

Several million tons of solid waste are produced each year as a result of construction and demolition activities around the world, and brick waste is one of the most widely wastes. Recently, there has been growing number in studies that conducted on using of recycling brick waste (RBW) to produce environmentally friendly concrete. The use of brick waste (BW) as potential partial cement or aggregate replacement materials is summarized in this review where the performance is discussed in the form of the mechanical strength and properties that related to durability of  concrete. It was found that, because the pozzolanic activity of clay brick powder, it can be utilized as substitute for cement in replacement level up to 10%. Whereas,

... Show More
Preview PDF
Crossref (5)
Crossref
Publication Date
Thu Mar 22 2018
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Assessment of medical solid waste generation rates for teaching hospitals in Baghdad city
...Show More Authors

Publication Date
Thu Apr 04 2024
Journal Name
Chemchemtech
ANALYTICAL TECHNIQUES IN PHARMACEUTICAL POLLUTION OF THE WORLD’S RIVERS; A REVIEW
...Show More Authors

Recent reports of new pollution issues brought on by the presence of medications in the aquatic environment have sparked a great deal of interest in studies aiming at analyzing and mitigating the associated environmental risks, as well as the extent of this contamination. The main sources of pharmaceutical contaminants in natural lakes and rivers include clinic sewage, pharmaceutical production wastewater, and sewage from residences that have been contaminated by drug users' excretions. In evaluating the health of rivers, pharmaceutical pollutants have been identified as one of the emerging pollutants. The previous studies showed that the contaminants in pharmaceuticals that are widely used are non-steroidal anti-inflammatory drugs, ant

... Show More
Scopus (6)
Scopus
Publication Date
Thu Mar 31 2016
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Performance of Compound Parabolic Concentrating Solar Collector
...Show More Authors

The design, construction and investigation of experimental study of two compound parabolic concentrators (CPCs) with tubular absorber have been presented. The performance of CPCs have been evaluated by using outdoor experimental measurements including the instantaneous thermal efficiency. The two CPCs are tested instantly by holding them on a common structure. Many tests are conducted in the present work by truncating one of them in three different levels. For each truncation the acceptance half angle (θc) was changed. Geometrically, the acceptance half angle for standard CPC is (26o). For the truncation levels for the other CPC 1, 2 and 3 the acceptance half angle were 20o, 26o and 5

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Gliding arc discharge for water treatment
...Show More Authors
Abstract<p>The significant shortage of usable water resources necessitated the creation of safe and non-polluting ways to sterilize water and rehabilitate it for use. The aim of the present study was to examine the ability of using a gliding arc discharge to inactivate bacteria in water. Three types of Bacteria satisfactory were used to pollute water which are Escherichia coli (Gram-negative), Staphylococcus aurous (Gram-positive) and salmonella (Gram-negative). A DC power supply 12V at 100 Hz frequency was employed to produce plasma. pH of water is measured gradually during the plasma treatment process. Contaminated water treated by gliding arc discharge at steadying the gas flow rate (1.5 l/mi</p> ... Show More
View Publication
Scopus (10)
Crossref (6)
Scopus Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations
...Show More Authors

The present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a

... Show More
Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations.
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination For Simultaneous Estimation Of Isoniazid And Ciprofloxacin In Mixture And Pharmaceutical Formulation
...Show More Authors

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 μg∙mL-1 for Ciprofloxacin and 2 to 22 μg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) wer

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Oct 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Normal and Reverse Flow Injection Analysis Methods for Estimation of Mesalazine in Pharmaceutical Dosage Forms
...Show More Authors

Determining the actual amounts of active ingredients in various pharmaceutical commercial forms is still receiving a lot of attention. Two flow injection analysis (FIA) methods were suggested for determination of mesalazine (MES) in pharmaceutical forms. Normal and reverse FIA systems (nFIA and rFIA) combined with UV-Vis spectrophotometric technique were used for the analysis. The methods involved using two mods of FIA systems for measuring a colored product result from coupling of MES with 2,2'-dihydroxybiphenyl after oxidized with sodium periodate in alkaline medium. The absorbance of the red colored dye was measured at maximum wavelength of 500 nm. The calibration graphs for MES were linear in the ranges 2.5-200 and 0.5-60 µg/mL with

... Show More
View Publication Preview PDF