Due to the broad range uses of chromium for industrial purposes, besides its carcinogenic effect, an efficient, cost effective removal method should be obtained. In this study, cow bones as a cheap raw material were utilized to produce active carbon (CBAC) by physiochemical activation, which was characterized using: SEM to investigate surface morphology and BET to estimate the specific surface area. The best surface area of CBAC was 595.9 m2/gm which was prepared at 600 ᵒC activation temperature and impregnation ratio of 1:1.5. CBAC was used in aqueous chromium ions adsorption. The investigated factors and their ranges are: initial concentration (10-50 mg/L), adsorption time (30-300 min), temperature (20-50 ᵒC) and solution pH (2-11). Isotherm of adsorption and its kinetics were studied. The adsorption process was modeled statistically and was represented by an empirical model. Equilibrium data were fitted to the Langmuir and Freundlich isotherm models and the data best represented by Freundlich isotherm. Pseudo- first order and pseudo- second order kinetic equations were utilized to study adsorption kinetics, where chromium adsorption on CBAC fitted pseudo- second order fitted the data more adequately. The best removal efficiency was found to be 94.32%.
In this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show MoreFor this research, the utilisation of electrocoagulation (EC) toremove theciprofloxacin (CIP) and levofloxacin (LVX) from aqueous solutions was examined. The effective removal efficiencies are 93.47% for CIP and 88.00% for LVX, under optimum conditions. The adsorption isotherm models with suitable mechanisms were applied to determine the elimination of CIP and LVX utilizingtheEC method. Thefindingsshowed the adsorption of CIP and LVX on iron hydroxide flocs followed the Sips isotherm, with correlation coefficient values (R2) of 0.939 and 0.937. Threekinetic models were reviewed to determine the accurate CIP and LVX elimination methods using the EC method. The results showed that itfittedfor the second-order model, which indicated that the c
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show MoreThe conservation for biodiversity in Iraqi freshwater environments is important to protecting native species from the environmental impacts of alien species. Clarias gariepinus (Burchell, 1822) (Siluriformes, Clariidae) has been recognized as an alien species in Iraqi water bodies. This study aims to use molecular DNA to identify this catfish and trace its origins using. The DNA sequences of C. gariepinus were done using the mitochondrial DNA cytochrome c oxidase subunit 1 (COI) gene, and a specific primer set. The polymerase chain reaction (PCR) amplification was used to align the COI gene as a barcoding marker. After analysis, the sequences were compared with sequences in the National Center for Biology Information (NCBI) database
... Show MoreThis study used deep eutectic solvent (DES) as the liquid membrane in a bulk liquid membrane system (BLM) to remove glycerol from waste cooking oil‐based biodiesel. The DES was prepared from choline chloride and tetraethylene glycol at a molar ratio of 1:5. Diethyl ether was employed as a novel strip phase for the glycerol in BLM. The effects of the DES: biodiesel ratio, stirring speed, and extraction time on the extraction and stripping efficiencies were investigated. The results showed that BLM could give better glycerol removal from biodiesel than mechanical shaking. Increasing the DES: biodiesel ratio, stirring speed, and extraction time can enhance glycerol removal from the feed phase, achievi
The Electro-Fenton oxidation process is one of the essential advanced electrochemical oxidation processes used to treat Phenol and its derivatives in wastewater. The Electro-Fenton oxidation process was carried out at an ambient temperature at different current density (2, 4, 6, 8 mA/cm2) for up to 6 h. Sodium Sulfate at a concentration of 0.05M was used as a supporting electrolyte, and 0.4 mM of Ferrous ion concentration (Fe2+) was used as a catalyst. The electrolyte cell consists of graphite modified by an electrodepositing layer of PbO2 on its surface as anode and carbon fiber modified with Graphene as a cathode. The results indicated that Phenol concentration decreases with an increase in current dens
... Show MoreOil flow lines are used to transport oil and its derivatives from a well over long distances, and because oil wells produce other potentially corrosive products, such as carbon dioxide and Hydrogen sulfide, it is necessary to take methods to protect the pipeline from corrosion. One of these methods is the use of corrosion inhibitors in this study. Prepare 5-acetyl-2-anilino-4-dimethylaminothiazole and test it as a corrosion inhibitor on a sample of the Rumaila flow line at a constant temperature 25°C in (3.5%) NaCl and (3.5%) KCl solution in the absence and presence of different concentrations of inhibitor (0 mM, 0.01 mM, 0.03 M, 0.05 mM). by using liner polarization (Tafel slope). The inhibiter exhibited the best performance at hi
... Show MoreForeign direct investment (FDI) has been viewed as a power affecting economic growth (EG) directly and indirectly during the past few decades. This paper reviewed an amount of researches examining the relationships between FDI and EG, especially the effects of FDI on EG, from 1994 up to 2012. The results show that the main finding of the FDI-EG relation is significantly positive, but in some cases it is negative or even null. And within the relation, there exist several influencing factors such as the adequate levels of human capital, the well-developed financial markets, the complementarity between domestic and foreign investment and the open trade regimes, etc.