This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there
is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated
The apricot plant was washed, dried, and powdered after harvesting to produce a fine powder that was used in water treatment. created an alcoholic extract from the apricot plant using ethanol, which was then analysed using GC-MS, Fourier transform infrared spectroscopy, and ultraviolet-visible spectroscopy to identify the active components. Zinc nanoparticles were created using an alcoholic extract. FTIR, UV-Vis, SEM, EDX, and TEM are used to characterize zinc nanoparticles. Using a continuous processing procedure, zinc nanoparticles with apricot extract and powder were employed to clean polluted water. Firstly, 2 g of zinc nanoparticles were used with 20 ml of polluted water, and the results were Tetra 44% and Levo 32%; after
... Show MoreEquilibrium adsorption isotherm for the removal of trifluralin from aqueous solutions using ? –alumina clay has been studied. The result shows that the isotherms were S3 according Giels classification. The effects of various experimental parameters such as contact time, adsorbent dosage, effect of pH and temperature of trifluralin on the adsorption capacities have been investigated. The adsorption isotherms were obtained by obeying freundlich adsorption isotherm with (R2 = 0.91249-0.8149). The thermodynamic parameters have been calculated by using the adsorption process at five different temperature, the values of ?H, ?G and ?S were (_1.0625) kj. mol-1, (7.628 - 7.831) kj.mol-1 and (_2.7966 - _2.9162) kg.
... Show MoreMultiple eliminations (de-multiple) are one of seismic processing steps to remove their effects and delineate the correct primary refractors. Using normal move out to flatten primaries is the way to eliminate multiples through transforming these data to frequency-wavenumber domain. The flatten primaries are aligned with zero axis of the frequency-wavenumber domain and any other reflection types (multiples and random noise) are distributed elsewhere. Dip-filter is applied to pass the aligned data and reject others will separate primaries from multiple after transforming the data back from frequency-wavenumber domain to time-distance domain. For that, a suggested name for this technique as normal move out- frequency-wavenumber domain
... Show MoreCombining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported
... Show MoreCombining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported
... Show MoreBodies of water are usually being polluted by wastes from domestic and industrial sources thereby making them unfit for use. Hence, this study aimed at assessing the water quality from Asa River, Ilorin, Nigeria in terms of bacteriological and physicochemical parameters. The bacteriological parameters assessed were heterotrophic bacterial count, total coliform, faecal coliform, identification of the isolates, antibiotic resistance patterns, and plasmid profile of the isolates. Whereas, the assessed physicochemical parameters were pH, total chloride, suspended solid, and total hardness. The heterotrophic bacterial count, total coliform, and faecal coliform counts ranged from 7.6 x 103 to 3.2 x 106 cfu/ml,
... Show MoreSawa Lake is one of the unique lakes in Iraq. It is located in the southwestern part of Iraq. It is one of the closed lakes, as no surface water source works to feed the lake. The lake feeds on groundwater. The source of this groundwater is the Dammam Basin. During the past ten years, The lake has had many changes, which led to a decrease in water levels. This also led attention to study of the causes of these changes. Many types of research were presented in the study of the state of the lake. This research used remote sensing images from Landsat 8 OLI to monitor the changes during 2020-2021 by applying the NDWI equation to extract water area from image data. The results of the areas were obtained from a special report by Normalized Dif
... Show MoreThe discharged water from tannery plants is main source for pollution of soil and groundwater, especially in Nahrawan area. Water samples is collected from 10 sites of wells, discharged water and from using water in different levels of tannery and 7 soil samples from different sites inside factories area and outside it. The results shown that pH for samples of wells and discharged water were within allowable limits between 6.5- 8.5, except the value of pH recorded in the discharged water sample (after the addition of calcium hydroxide) was 12.8, as well as reached the highest value of total dissolved salts (TDS) 7800 ppm in same samples. It also reached its highest value of electrical conductivity (EC) 8200 μS/cm. The results showed tha
... Show More