Preferred Language
Articles
/
ijcpe-526
Heat Transfer in Bubble Column Contactors with immersed Coiled Heater
...Show More Authors

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Heat Shock Protein70 as Biomarker in Bladder Cancer
...Show More Authors

The present study aimed to shed light on the urine HSP70 concentration of patients with urinary bladder carcinoma UBC and control subjects as new urinary biomarker. The second aim was to associate this protein concentration with UBC stage and grade in patients with UBC. A direct ELISA was used to quantify urine HSP concentrations in 58 patients with urinary bladder carcinoma UBC with different grades (G) and stages (T) all malignant of them was transitional cell carcinoma (TCC) type , 15 from patients with urinary Bladder disorders other than cancer UBD and 15 healthy subjects(control) . Urine concentrations of HSP70 were elevated in patients with UBC compared to those without UBC (healthy and UBD, P< 0.5). There was a high signifi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Micro-Bubble Flotation for Removing Cadmium Ions from Aqueous Solution: Artificial Neural Network Modeling and Kinetic of Flotation
...Show More Authors

In this work, microbubble dispersed air flotation technique was applied for cadmium ions removal from wastewater aqueous solution. Experiments parameters such as pH (3, 4, 5, and 6), initial Cd(II) ions concentration (40, 80, and 120 mg/l)  contact time( 2, 5, 10 , 15, and 20min), and surfactant (10, 20and 40mg/l) were studied in order to optimize the best conditions .The experimental results indicate that microbubbles were quite effective in removing cadmium ions and the anionic surfactant SDS was found to be more efficient than cationic CTAB in flotation process. 92.3% maximum removal efficiency achieved through 15min at pH 5, SDS surfactant concentration 20mg/l, flow rate250 cm3/min and at 40mg/l Cd(II) ions initial co

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
International Journal Of Geomate
NONLINEAR SIMULATION ANALYSIS OF TAPERED REINFORCED CONCRETE COLUMN (SOLID AND HOLLOW) BEHAVIOR UNDER AXIAL LOAD
...Show More Authors

View Publication
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Aug 30 2018
Journal Name
Journal Of Engineering
Mass Transfer Study for Bio-Synergy in Dairy Wastewater Treatment Plant
...Show More Authors

The present study addresses the behavior of gases in cultivation media as an essential factor to develop the relationship between the microorganisms that are present in the same environment. This relationship was explained via mass transfer of those gases to be a reasonable driving force in changing biological trends. Stripping and dissolution of oxygen and carbon dioxide in water and dairy wastewater were investigated in this study. Bubble column bioreactor under thermal control system was constructed and used for these processes. The experimental results showed that the removal of gases from the culture media requires more time than the dissolution. For example, the volumetric mass transfer coefficient for the removal

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Oct 24 2018
Journal Name
Journal Of Economics And Administrative Sciences
"The Relationship critical factors for knowledge transfer in strategic success opportunities"
...Show More Authors

    The current research discusses "The Relationship critical factors for knowledge transfer in strategic success opportunities", the attention have been increased on knowledge transfer and strategic success subjects because on being one of the important and contemporary issues, which have a significant impact on the existence of organizations and its future. The research aims to identify the critical factors for knowledge transfer in private high education environment which enables (the college community surveyed) to achieve strategic success, also the research sought to answer questions related to research problem by testing a number of major and minor hypothes in correlation, in order to test the hypotheses I us

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 02 2015
Journal Name
Lap Lambert Academic Publishing
The role of tibialis posterior transfer in correction of foot drop
...Show More Authors

View Publication Preview PDF
Publication Date
Tue May 01 2018
Journal Name
Journal Of Engineering
Prediction of the Effect of Using Stone Column in Clayey Soil on the Behavior of Circular Footing by ANN Model
...Show More Authors

Shallow foundations are usually used for structures with light to moderate loads where the soil underneath can carry them. In some cases, soil strength and/or other properties are not adequate and require improvement using one of the ground improvement techniques. Stone column is one of the common improvement techniques in which a column of stone is installed vertically in clayey soils. Stone columns are usually used to increase soil strength and to accelerate soil consolidation by acting as vertical drains. Many researches have been done to estimate the behavior of the improved soil. However, none of them considered the effect of stone column geometry on the behavior of the circular footing. In this research, finite ele

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Mar 30 2024
Journal Name
Al-qadisiyah Journal For Engineering Sciences
Investigation of an automobile air-conditioner with a liquid-suction heat exchanger using R134a and R1234yf
...Show More Authors

Air-conditioning systems (ACs) are essential in hot and humid climates to ensure acceptable ambient air quality as well as thermal comfort for buildings users. It is essential to improve refrigeration system performance without increasing the effects of global warming potential (GWP) and ozone depletion potential (ODP). The main objective of this study is to evaluate the performance of an air conditioning system that operates with a liquid suction heat exchanger (LSHX) through implementing refrigerants with zero OPD and low GWP (i.e., R134a and R1234yf). Liquid suction heat exchanger (LSHX) was added to an automobile air conditioning system (AACS).When Liquid suction heat exchanger was added to the cycle, primary results indicated t

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Jan 26 2022
Journal Name
Nanomaterials
Improved Melting of Latent Heat Storage Using Fin Arrays with Non-Uniform Dimensions and Distinct Patterns
...Show More Authors

Employing phase-change materials (PCM) is considered a very efficient and cost-effective option for addressing the mismatch between the energy supply and the demand. The high storage density, little temperature degradation, and ease of material processing register the PCM as a key candidate for the thermal energy storage system. However, the sluggish response rates during their melting and solidification processes limit their applications and consequently require the inclusion of heat transfer enhancers. This research aims to investigate the potential enhancement of circular fins on intensifying the PCM thermal response in a vertical triple-tube casing. Fin arrays of non-uniform dimensions and distinct distribution patterns were des

... Show More
View Publication
Scopus (46)
Crossref (49)
Scopus Clarivate Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Sustainability
Experimental Evaluation of the Thermoelectrical Performance of Photovoltaic-Thermal Systems with a Water-Cooled Heat Sink
...Show More Authors

A design for a photovoltaic-thermal (PVT) assembly with a water-cooled heat sink was planned, constructed, and experimentally evaluated in the climatic conditions of the southern region of Iraq during the summertime. The water-cooled heat sink was applied to thermally manage the PV cells, in order to boost the electrical output of the PVT system. A set of temperature sensors was installed to monitor the water intake, exit, and cell temperatures. The climatic parameters including the wind velocity, atmospheric pressure, and solar irradiation were also monitored on a daily basis. The effects of solar irradiation on the average PV temperature, electrical power, and overall electrical-thermal efficiency were investigated. The findings i

... Show More
View Publication
Scopus (31)
Crossref (29)
Scopus Clarivate Crossref