Preferred Language
Articles
/
ijcpe-507
Removal Of Dissolved Cadmium Ions from Contaminated Wastewater using Raw Scrap Zero-Valent Iron And Zero Valent Aluminum as Locally Available and Inexpensive Sorbent Wastes
...Show More Authors

The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained. Langmuir and Freundlich isotherms were presumed to fit the batch kinetics data for the sorption of Cd(II) onto ZVAI and/or ZVI and found that Langmuir (I) was the most representative model type with coefficient of determination R2 greater than 0.9115. Kinetics data for the sorption of Cd(II) onto ZVAI/ZVI mixture and due to the good agreement between the fitted and the experimental results; the data was found to obey the pseudo second order model. The scanning electron microscopy (SEM) for the ZVI and ZVAI was conducted before and after the sorbent-liquid reaction and revealed distinct morphological changes in the sorbent surface due to the contaminant saturation and pore channel blockages that ceased the sorption process.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 26 2012
Journal Name
Journal Of Kufa For Chemical Sciences
Synthesis and Characterization of some lanthanide Metal ions Complexes of Schiff Bases derived From p-fluoro benzoic acid and thiosemicarbazide
...Show More Authors

Reaction of  p-fluoro benzoic acid with the thiosemicarbazide and salcialdehyde gave the new bidentate ligand .The prepared ligand Identified by FT-I.R and U.V-Visible spectcopic technique .Treatment of the prepared   ligand   with following metal ions  M=Tb(III),Eu(III),Nd(III) and La(III) ,in ethanol with a (1:1) M:L ratio and at pH=7 yielded series of neutral complexes as the general formula  [M LCl (H O ]. The prepared complexes were characterized using (FT-IR, UV-Vis) spectra , melting point, molar conductivity measurements . chloride ion content were also evolution by (mhor method) . The proposed structure of the complexes using program , chem office 3D(2004) .

Publication Date
Sun Jan 01 2023
Journal Name
مجلة الأطروحة العلمية المحكمة-العلوم الصرفة والتطبيقية
Detection of Lead (Pb) and Cadmium (Cd) Concentrations in Some Indomie Samples
...Show More Authors

Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
A Competitive Study Using UV and Ozone with H2O2 in Treatment of Oily Wastewater
...Show More Authors

          In this study, ultraviolet (UV), ozone techniques with hydrogen peroxide oxidant were used to treat the wastewater which is produced from South Baghdad Power Station using lab-scale system. From UV-H2O2 experiments, it was shown that the optimum exposure time was 80 min. At this time, the highest removal percentages of oil, COD, and TOC were 84.69 %, 56.33 % and 50 % respectively. Effect of pH on the contaminants removing was studied in the range of (2-12). The best oil, COD, and TOC removal percentages (69.38 %, 70 % and 52 %) using H2O2/UV were at pH=12. H2O2/ozone experiments exhibited better performance compared to

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Baghdad Science Journal
Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
...Show More Authors

This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) b

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jun 30 2021
Journal Name
International Journal Of Research In Medical Sciences & Technology
GREEN SYNTHESIS OF SILVER NANOPARTICLE USING GREEN TEA LEAVES EXTRACT FOR REMOVAL CIPROFLOXACIN (CIP) FROM AQUEOUS MEDIA
...Show More Authors

This study examines the removal of ciprofloxacin in an aqueous solution using green tea silver nanoparticles (Ag-NPs). The synthesized Ag-NPs have been classified by the different techniques of SEM, AFM, BET, FTIR, and Zeta potential. Spherical nanoparticles with average sizes of 32 nm and a surface area of 1.2387m2/g are found to be silver nanoparticles. The results showed that the ciprofloxacin removal efficiency depends on the initial pH (2.5-10), CIP (2-15 mg/L), temperature (20-50°C), time (0-180 min), and Ag-NPs dosage (0.1-1g/L). Batch experiments revealed that the removal rate with ratio (1:1) (w/w) were 52%, and 79.8% of the 10 mg/L of CIP at 60, and 180 minutes, respectively with optimal pH=4. Kinetic models for adsorpti

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Dec 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrolytic removal of zinc from simulated chloride wastewaters using a novel flow-by fixed bed electrochemical reactor
...Show More Authors

The cathodic deposition of zinc from simulated chloride wastewater was used to characterize the mass transport properties of a flow-by fixed bed electrochemical reactor composed of vertical stack  of stainless steel nets, operated in batch-recycle mode. The electrochemical reactor employed potential value in such a way that the zinc reduction occurred under mass transport control. This potential was determined by hydrodynamic voltammetry using a borate/chloride solution as supporting electrolyte on stainless steel rotating disc electrode. The results indicate that mass transfer coefficient (Km) increases with increasing of flow rate (Q) where .The electrochemical reactor proved to be efficient in removing zinc and was abl

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 01 2025
Journal Name
Iop Conference Series: Earth And Environmental Science
Review Article: Iron, Zinc and Boron in Sunflower
...Show More Authors

There is a real problem when adding micro elements to the soil as a result of fixation, sedimentation, washing or toxicity, and thus economic loss. The plant needs micro elements in very small quantities that do not burn the leaves or cause poisoning to plants, including iron, zinc and boron, as they are essential elements for growth and completing the plant's life cycle, and increase the plant's resistance to diseases and insects, activate enzymes, and form the chlorophyll molecule, in addition to their role in oxidation and reduction processes and vital processes. The use of fertilizers with their modern technology has made the process of activating seeds or foliar nutrition a matter of interest to researchers as a complementary process t

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Alexandria Engineering Journal
Batch and continuous study of one-step sustainable green graphene sand hybrid synthesized from Date-syrup for remediation of contaminated groundwater
...Show More Authors

Scopus (23)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Geological Journal
Multiple and Coherent Noise Removal from X-Profile 2D Seismic Data of Southern Iraq Using Common Depth Point Muting Procedures and Depending on Madagascar Open-Source Package
...Show More Authors

This article describes how to predict different types of multiple reflections in pre-track seismic data. The characteristics of multiple reflections can be expressed as a combination of the characteristics of primary reflections. Multiple velocities always come in lower magnitude than the primaries, this is the base for separating them during Normal Move Out correction. The muting procedure is applied in Time-Velocity analysis domain. Semblance plot is used to diagnose multiples availability and judgment for muting dimensions. This processing procedure is used to eliminate internal multiples from real 2D seismic data from southern Iraq in two stages. The first is conventional Normal Move Out correction and velocity auto picking and

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Dec 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of metal ions release and corrosion potential from different bracket archwire combinations (An in vitro study)
...Show More Authors

Background: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar

... Show More
View Publication Preview PDF