Preferred Language
Articles
/
ijcpe-494
Prediction of Fractional Hold-Up in RDC Column Using Artificial Neural Network
...Show More Authors

In the literature, several correlations have been proposed for hold-up prediction in rotating disk contactor. However,
these correlations fail to predict hold-up over wide range of conditions. Based on a databank of around 611
measurements collected from the open literature, a correlation for hold up was derived using Artificial Neiral Network
(ANN) modeling. The dispersed phase hold up was found to be a function of six parameters: N, vc , vd , Dr , c d m / m ,
s . Statistical analysis showed that the proposed correlation has an Average Absolute Relative Error (AARE) of 6.52%
and Standard Deviation (SD) 9.21%. A comparison with selected correlations in the literature showed that the
developed ANN correlation noticeably improved prediction of dispersed phase hold up. The developed correlation also
shows better prediction over a wide range of operation parameters in RDC columns.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Phenylephrine hydrochloride and Salbutamol sulphate drugs in pharmaceutical preparations using diazotized Metoclopramide hydrochloride
...Show More Authors

A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and l

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Aug 01 2019
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Evaluation of routing protocol with multi-mobile sinks in WSNs using QoS and energy consumption parameters
...Show More Authors

An efficient networks’ energy consumption and Quality of Services (QoS) are considered the most important issues, to evaluate the route quality of the designed routing protocol in Wireless Sensor Networks (WSNs). This study is presented an evaluation performance technique to evaluate two routing protocols: Secure for Mobile Sink Node location using Dynamic Routing Protocol (SMSNDRP) and routing protocol that used K-means algorithm to form Data Gathered Path (KM-DGP), on small and large network with Group of Mobile Sinks (GMSs). The propose technique is based on QoS and sensor nodes’ energy consumption parameters to assess route quality and networks’ energy usage. The evaluation technique is conducted on two routing protocols i

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
Spatial distribution of some fertility elements in some northern Iraqi soils using geomatic techniques (remote sensing)
...Show More Authors

Scopus
Publication Date
Sun Jul 01 2018
Journal Name
Computers And Electronics In Agriculture
Detection of charcoal rot (Macrophomina phaseolina) toxin effects in soybean (Glycine max) seedlings using hyperspectral spectroscopy
...Show More Authors

View Publication
Scopus (16)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Wed Oct 01 2008
Journal Name
Journal
Topical therapy of acne vulgaris using 2% tea lotion in comparison with 5% zinc sulphate solution
...Show More Authors

S Khalifa E, N Adil A, AS Mazin M…, 2008

View Publication
Scopus (41)
Scopus
Publication Date
Fri Dec 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Sensitive Cloud Point Extraction Method for the Determination of Isoxsuprine Hydrochloride in Pharmaceutical forms using Spectrophotometry
...Show More Authors

      A simple and highly sensitive cloud point extraction process was suggested for preconcentration of micrograms amount of isoxsuprine hydrochloride (ISX) in pure and pharmaceutical samples. After diazotization coupling of ISX with diazotized sulfadimidine in alkaline medium, the azo-dye product quantitatively extracted into the Triton X-114 rich phase, dissolved in ethanol and determined spectrophotometrically at 490 nm. The suggested reaction was studied with and without extraction and simple comparison between the batch and CPE methods was achieved. Analytical variables including concentrations of reagent, Triton X-114 and base, incubated temperature, and time were carefully studied. Under the selected opti

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
Determination of Sulfacetamide Sodium in Pure and Their Pharmaceutical Formulations by Using Cloud Point Extraction Method
...Show More Authors

      In this study, simple, low cost, precise and speed spectrophotometric methods development for evaluation of sulfacetamide sodium are described. The primary approach contains conversion of sulfacetamide sodium to diazonium salt followed by a reaction with p-cresol as a reagent in the alkaline media.  The colored product has an orange colour with absorbance at λmax 450 nm. At the concentration range of (5.0-100 µg.mL-1), the Beer̆ s Low is obeyed with correlation coefficient (R2= 0.9996), limit of detection as 0.2142 µg.mL-1, limit of quantification as 0.707 µg.mL-1 and molar absorptivity as 1488.249 L.mol-1.cm-1. The other approach, cloud point extraction w

... Show More
View Publication Preview PDF
Scopus (8)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Decolorization of Phenol Red Dye by Immobilized Laccase in Chitosan Beads Using Laccase - Mediator - System Model
...Show More Authors

This work describes the enhancement of phenol red decolorization through immobilizing of laccase in chitosan and enzyme recycling. Commercial laccase from white rot fungus, Trametesversicolor (Tvlac), was immobilizedin to freshly prepared chitosan beads by using glutaraldehyde as a cross linker. Characterization of prepared chitosan was confirmed by FTIR and scanning electron microscope (SEM). Tvlac (46.2 U/mL) immobilized into chitosan beads at 0.8 % glutaraldehyde (v/v) within 24 hrs. Synthetic (HBT) and natural (vanillin) mediators were used to enhance dye decolorizoation. It was found that 89 % of phenol red was decolorized by chitosan beads within 180 min. in the absence of enzyme and mediator, while decolorization percenta

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Determination of paracetemol in pharmaceutical preparations samples by spectrophotometer using meta phenylenediamine as a chromogenic agent
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 20 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of maxillary sinus septal type and height in partially edentulous maxilla using spiral computed tomography
...Show More Authors

Background: The presence of anatomic variations within the maxillary sinus such as septa has been reported to increase the risk of sinus membrane perforation during sinus elevation procedure for implant placement. This study aimed to measure the septal heights and correlate it with different types of septa. Material and methods: Thirty patients (15 males and 15 females) with partially edentulous maxillae and mean age (35) years were enrolled in this study. Sixty sinuses scanned with Spiral multislice Computed Tompgraphy, septal height measured after evaluation of septal type whether it was primary or secondary. Results: The results showed that 72.5 % of the septa detected were primary and this is statistically significant when compared w

... Show More
View Publication Preview PDF