Recent research has examined the improvement of physical and dielectric properties of BaTiO3 ceramic material by small addition of excess TiO2 or BaCO3. The prepared samples sintered at different temperatures and varying soaking time. The results show that increasing the sintering temperature within 1350°C and soaking time of 10 hrs give better electrical and physical properties, which indicate the reaction is complete at higher temperature and period.
In order to understand the effect of (length of pile / diameter of pile) ratio on the load carrying capacity and settlement reduction behavior of piled raft resting on loose sand, laboratory model tests were conducted on small-scale models. The parameters studied were the effect of pile length and the number of piles. The load settlement behavior obtained from the tests has been validated by using 3-D finite element in ABAQUS program, was adopted to understand the load carrying response of piled raft and settlement reduction. The results of experimental work show that the increase in (Lp/dp) ratio led to increase in load carrying capacity by piled raft from (19.75 to 29.35%), (14.18 to 28.87%) and (0 to 16.49%) , the maximum load carr
... Show MoreThis study was designed for isolation and molecular identification of Nontuberculous Mycobacterium (NTM) from fish during the period between October and December 2017 from Karbla province, Iraq. This study included 200 fresh fish samples from four different species including Spondyliosoma cantharus, Liza abu, Carassius carassius and Cyprinuscarpio. Three samples of each fish were taken including gills, muscles and all internal organs. The samples were processed by decontamination, concentration of 4% sodium hydroxide, and 0.1 ml of sediment was streaking on Löwenstein Johnson (LJ) media; then the bacterial cultures were incubated at 28-30 °C for 3days up to 4 weeks and suspected colonies were stained with acid fast stain to confir
... Show MoreBackground: With the increased in the demands of adult orthodontics, the challenge of direct bonding to non-enamel surface (zirconium) had been increased. The present study was carried out to compare the shear bond strength of three different brackets (stainless steel, sapphire and composite) bonded to zirconium surface and study the mode of bond failure. Materials and methods: The sample was comprised of 30 models (8mm *6mm*1.5mm) of full contour zirconium veneers. They were divided into three groups according to the brackets type; all samples were treated first by sandblast with aluminum oxide particle 50 µm then coated by z-prime plus primer. A central incisor bracket of each group was bonded to the prepared zirconium surface with lig
... Show MoreAbstract:
The research aims to identify how to audit potential liabilities and contingent liabilities in light of the pandemic and its reflection on the auditor's report. The research problem is represented by the complexity of the process of checking potential liabilities and contingent liabilities in insurance companies, which was negatively reflected in the auditor's neutral technical opinion. The researchers hypothesize that auditing potential liabilities and contingent liabilities in light of the Corona pandemic is positively reflected in the auditor's report. The research concludes that the process of checking potential liabilities and contingent liabilities is
... Show MoreAccounting disclosure is the main means and effective tool for communicating business results to users in support of their decisions, especially those with thought and specialization from academics and professionals in the field of accounting and auditing about the importance of accounting disclosure and transparency in financial reports.
Contingent liabilities represent commitments based on the occurrence of one or more events in the future to confirm the value due, the party entitled to it, the maturity date, or to confirm the existence of the obligation itself, and therefore they should not be recognized as a contingent liability i
... Show Morehe paper presents the results of exposure of normal concrete to high temperatures (400 and 700°C). In addition to the exposure of steel reinforcement bar Ø 12 mm, where two types of steel reinforcement burning situations were performed. Directly exposed to high temperatures (400 and 700°C) and others were covered by concrete layer (15 mm). From the experimental results of fire exposure for 1 hour of 400 and 700°C and gradually cooled, it was found that the residual average percentage of compressive strength of concrete was 85.3 and 41.4%, while the residual average percentage of modulus of elasticity of concrete was 75 and 48%, respectively. The residual average percentage of yielding tensile stress (Ø 12 mm) after burning and cooling
... Show MoreThe synthesis, characterization and liquid crystalline properties of N4,N40-bis((1 H-benzo[d]imidazol-2- yl)methyl)-3,30-dimethyl-[1,10-biphenyl]-4,40-diamine and of their corresponding Mn(II), Fe(II), Ni (II), Cu(II), and Zn(II) complexes are described. The ligand and complexes have been characterized by elemental analysis, magnetic susceptibility measurements (meff), conductometric measurements and Fourier Transform Infrared (FTIR), Nuclear Magnetic Resonance (1H NMR), (13C-NMR) and UV–Vis spectroscopy. Spectral investigations suggested octahedral coordination geometrical arrangement for M(II) complexes. The phase transition temperatures were detected by differential scanning calorimetry (DSC) analysis and the phases are confirmed by op
... Show More