Preferred Language
Articles
/
ijcpe-459
Performance of Pulsator Clarifier (Low Turbidity)

Experimental and theoretical investigations are presented on flocculation process in pulsator clarifier. Experimental system was designed to study the factors that affecting the performance of pulsator clarifier. These factors were water level in vacuum chamber which range from 60 to 150 cm , rising time of water in vacuum chamber which having times of 20,30 & 40 seconds , and sludge blanket height which having heights of 20,30 & 40 cm .The turbidity and pH of raw water used were 200 NTU and 8.13 respectively. According to the jar test, the alum dose required for this turbidity was 20 mg/l .The performance parameters of pulsator clarifier such as , turbidity ,total solid TS , shear rate , volume concentration of sludge blanket and the flocculation criteria were studied. It was observed that by decreasing the water level in vacuum tube and by increasing the rising time and sludge blanket height , low turbidity of output water attained. Moreover, flocculation criteria value GCt was within the optimum range values (100-500) .A theoretical models was applied for total solids TS of output water .The difference between experimental and theoretical data was ranged between (11-24)% of mean deviation at water level range of (125-150)cm and sludge blanket height 20 cm.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Water Flow Visualization And Velocity Measurement Using Hydrogen Bubble Generation Technique In Low Speed Open Channel

Visualization of water flow around different bluff bodies at different Reynolds number ranging (1505 - 2492) was realized by designing and building a test rig which contains an open channel capable to ensure water velocity range (4-8cm/s) in this channel. Hydrogen bubbles generated from the ionized water using DC power supply are visualized by a light source and photographed by a digital camera. Flow pattern around a circular disk of (3.6cm) diameter and (3mm) thickness, a sphere of (3.8cm) diameter and a cylinder of
(3.2cm) diameter and (10cm) length are studied qualitatively. Parameters of the vortex ring generated in the wake region of the disk and the separation angle of water stream lines from the surface of the sphere are plott

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Sun Oct 01 2006
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Modified Automated Scoring system for Immunohistochemical staining using commercially available low cost software for image analysis

Background: During the past several years, there has been a rapidly escalating clinical need to perform IHC stains that require quantitative interpretation. Automated Cellular
Imaging System is used to analyze immunohistochemically stained slides, primarily for cancer-related diagnostics. Studies have shown that the device offers accuracy,
precision, and reproducibility of immunostained slide analysis exceeding that possible with manual evaluation, which was the prevailing method.
Aim of the study In this article we will demonstrate that meaningful image analysis of immunohistochemical staining studies can be performed using inexpensive, widely distributed
graphics software (Adobe Photoshop) on a personal

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Creating a LabVIEW Sub VI for the INA219 Sensor for Detecting Extremely Low-Level Electrical Quantities

An impressed current cathodic protection system (ICCP) requires measurements of extremely low-level quantities of its electrical characteristics. The current experimental work utilized the Adafruit INA219 sensor module for acquiring the values for voltage, current, and power of a default load, which consumes quite low power and simulates an ICCP system. The main problem is the adaptation of the INA219 sensor to the LabVIEW environment due to the absence of the library of this sensor. This work is devoted to the adaptation of the Adafruit INA219 sensor module in the LabVIEW environment through creating, developing, and successfully testing a Sub VI to be ready for employment in an ICCP system. The sensor output was monitored with an Ardui

... Show More
Crossref (2)
Crossref
View Publication Preview PDF
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of The Faculty Of The Medicine Baghdad
Do low back pain changes correlate with sagittal lumbar alignment changes after total hip replacement arthroplasty?

Abstract Background: The hip joint and lumbar spine are both anatomically and functionally closely related as had shown by many authors. So the abnormality in one area can affect the other e.g. hip joint osteoarthritis can cause lumbar sagittal malalignment and backache. Objectives: is to see if there is significant improvement in backache after total hip replacement? And which degree of backache improvement is associated with significant changes in lumbar lordosis? Methods and patients: a prospective open trial study was performed on 30 patients who had severe hip osteoarthritis and chronic low back pain. Total hip replacement was performed to all patients. Backache and lumbar lordosis were measured by visual analogue scale and Cobb’s a

... Show More
Preview PDF
Publication Date
Mon Jun 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Performance Series Performance Metrics (*) A case study in the General Company for Cotton Industries

The problem of the research is focused on importance limited of Iraq industrial companies in application of scientific measurements of supply chains performance,  The research sought to achieve a group of goals, the most important are , identifying the strengths and weaknesses in the reality of supply chain in General Company for Cotton Industries, The data and information required are gathered from the dependence company, records through the field observations and personal interviews, the research used some quantitative indicators to measure of supply chain performance, The research reached to many conclusions , the most outstanding among them is the existence of a strong inverse correlatio

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sat Jul 01 2017
Journal Name
International Journal Of Computer Networks And Wireless Communications
Performance Analysis of VoIP in Wireless Networks

Voice over Internet Protocol (VoIP) is important technology that’s rapidly growing in the wireless networks. The Quality of Service (QoS) and Capacity are two of the most important issues that still need to be researched on wireless VoIP. The main aim of this paper is to analysis the performance of the VoIP application in wireless networks, with respect to different transport layer protocols and audio codec. Two scenarios used in the simulation stage. In the first scenario VoIP with codec G.711 transmitted over User Datagram Protocol (UDP), Stream Control Transmission Protocol (SCTP), and Real-Time Transport Protocol (RTP). While, in the second scenario VoIP with codec G.726 transmitted over UDP, SCTP, and RTP protocols. Network simulator

... Show More
View Publication
Publication Date
Wed Nov 03 2021
Journal Name
Journal Of Engineering Research
Performance of quadrilateral perforated prestressed concrete rafters

This study focuses on the behavior of simply supported perforated prestressed concrete rafters (PPCRs) under single midspan monotonic static loading. The experimental program consisted of testing seven specimens; one solid (control) rafter, and six perforated with quadrilateral openings. The main investigated variables are the number and height of the openings. The test findings indicate that, in comparison to the solid rafter, the presence of quadrilateral openings in the PPCRs led to reducing the load capacity by (4.3-36%) and increase the midspan deflection at ultimate by (14.8-33%). Also, increasing the number of concrete posts between openings resulted in increasing the failure load and decreasing the deflection at all stages o

... Show More
Crossref (1)
Crossref
View Publication
Publication Date
Mon Feb 19 2018
Journal Name
Al-academy
Performance of the comedian in Moliere plays

This research aims to study the performance of comedian in the plays of writer Moliere . The problem of research is to answer the following question:      How does comedian Moliere's techniques in a number of his plays and funny acts?   The    research aims at revealing the means used by the comedian in his performance of a comedic character in the number of Moliere plays.                                                 

   &

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
STATIC PERFORMANCE CHARACTERISTICS OF VORTEX RATE SENSOR

The vortex rate sensor is a fluidic gyroscope with no moving parts and can be used in very difficult
conditions like radiation, high temperature and noise with minimum cost of manufacturing and
maintenance. A vortex rate sensor made of wood has been designed and manufactured to study
theoretically and experimentally its static performance .A rig has been built to carry out the study,
the test carried out with three different air flow rates (100, 150, and 200 l/min).The results show that
the relation between the differential pressure taken from the sensor pickoff points and the angular
velocity of the sensor was linear.The present work involved theoretical and experimental study of
vortex rate sensor static characteri

... Show More
Crossref
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Static Performance Characteristics Of Vortex Rate Sensor

The vortex rate sensor is a fluidic gyroscope with no moving parts and can be used in very difficult conditions like radiation, high temperature and noise with minimum cost of manufacturing and maintenance. A vortex rate sensor made of wood has been designed and manufactured to study theoretically and experimentally its static performance .A rig has been built to carry out the study,
the test carried out with three different air flow rates (100, 150, and 200 l/min).The results show that the relation between the differential pressure taken from the sensor pickoff points and the angular velocity of the sensor was linear.The present work involved theoretical and experimental study of vortex rate sensor static characteristics .Vortex rat

... Show More
Crossref
View Publication Preview PDF