Preferred Language
Articles
/
ijcpe-459
Performance of Pulsator Clarifier (Low Turbidity)
...Show More Authors

Experimental and theoretical investigations are presented on flocculation process in pulsator clarifier. Experimental system was designed to study the factors that affecting the performance of pulsator clarifier. These factors were water level in vacuum chamber which range from 60 to 150 cm , rising time of water in vacuum chamber which having times of 20,30 & 40 seconds , and sludge blanket height which having heights of 20,30 & 40 cm .The turbidity and pH of raw water used were 200 NTU and 8.13 respectively. According to the jar test, the alum dose required for this turbidity was 20 mg/l .The performance parameters of pulsator clarifier such as , turbidity ,total solid TS , shear rate , volume concentration of sludge blanket and the flocculation criteria were studied. It was observed that by decreasing the water level in vacuum tube and by increasing the rising time and sludge blanket height , low turbidity of output water attained. Moreover, flocculation criteria value GCt was within the optimum range values (100-500) .A theoretical models was applied for total solids TS of output water .The difference between experimental and theoretical data was ranged between (11-24)% of mean deviation at water level range of (125-150)cm and sludge blanket height 20 cm.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of Biology, Agriculture And Healthcare
Histopathological Changes of Some Internal Organs of Mice Injected with Exotoxin a at Low Concentrations
...Show More Authors

Abstract Exotoxin A is the most lethal virulence factor produced by Pseudomonas aeruginosa. It inhibits elongation factor-2 by ADP-ribosylation of EF2. This causes stop of the elongation of polypeptides. In recent study, the effect of low concentration of exotoxin A on some important internal organs of mice was studied. Four groups white mice were injected intraperitonialy with pure exotoxin A in the following manner 0.1, 0.2, 0.3, 0.4 ng\ animals. One mouse receives normal saline inrtaperitonialy as a control. After 72 hours the mice were killed and four organs were taken, liver, spleen, lung and heart from each killed mice. Histological sections were made from each organ and stained with hematoxylin and eosin stain then examined under mic

... Show More
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
Evaluation of Low Level Laser Therapy Using Diode Laser in Enhancement of Episiotomy Wound Healing
...Show More Authors

we studied the effect of low level laser therapy (LLLT) using diode laser with wavelength of (790-805) nm in promotion and enhancement of wound healing of episiotomy and to evaluate the analgesic effect of LLLT in reducing the pain sensation caused by the episiotomy wounds. Nineteen women with episiotomy wound were selected and divided into three groups; 1st group (group No.1: control group) given antibiotics without laser therapy, in the 2nd group (group No.2) the wounds were exposed to laser therapy (4 sessions, each session with energy density of 19.90 J /cm2 every other day ) and systemic antibiotics were prescribed for 1 week. In the 3rd group (group No.3) the wounds were exposed to laser therapy (4 sessions, the same as in the 2nd

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 25 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Analysis of inflammatory cells in osseointegration of CpTi implant radiated by low level laser therapy
...Show More Authors

Background: Dental implants provide a unique treatment modality for the replacement of a lost dentition .This is accomplished by the insertion of relatively an inert material (a biomaterial) into the soft and hard tissue of the jaws, there by providing support and retention for dental prostheses. Low level laser therapy (LLLT) is an effective tool used to prompt bone repair and remodeling, this has referred to the biostimulation effect of LLLT. The Aim of this study was to evaluate the effects of inflammatory cells on osseointegration of CpTi implant irradiated by low level laser. Materials and Methods: thirty two adult New Zealand white rabbits, received titanium implants were inserted in the tibia. The right side is considered as experime

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Improvement of the surface hardness and wear resistant of low carbon steel using laser radiation
...Show More Authors

0

View Publication Preview PDF
Publication Date
Thu Oct 01 2009
Journal Name
Iraqi Journal Of Physics
Investigation of Beta - irradiation effects on the microstructure of Low Density Polyethylene (LDPE) using (PALT)
...Show More Authors

Beta-irradiation effects on the microstructure of LDPE samples have been investigated
using Positron Annihilation Lifetime Technique (PALT). These effects on the orthopositronium
(o-Ps) Lifetime t3, the free positron annihilation lifetime 2 t , the free-volume
hole size (Vh) and the free volume fraction (fh) were measured as functions of Beta
irradiation - dose up to a total dose of 30.28 kGy.
The results show that the values of t3, Vh and fh increase gradually with increasing Beta
dose up to a total dose of 1.289 kGy, and reach a maximum increment of 17.4%, 32.8% and
5.86%, respectively, while t2 reachs maximum increment of 211.9% at a total dose of 1.59
kGy. Above these doses, the values show nonlinear changes u

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Influence of Glow and Afterglow Times on the Discharge Current of Argon at Low Pressure
...Show More Authors

     An experimental investigation of the variation of argon discharge current with a glow and afterglow time intervals of a square discharge voltage was carried out at low pressure (6-11 mbar). The discharge was created between two circular metal electrodes of diameter (7.5 cm), separated horizontally by a distance (10 cm) at the two ends of a Pyrex cylindrical tube. A composite of two Gaussian functions has been suggested to fit and explain the variation graphs clearly. It is shown that the necessary times of glow and afterglow needed to attain a maximum discharge current are (70 us) and (60 us), respectively. The discharge current is observed to drop to the lowest value when the two times are serially longer than (85 us) and (72 u

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Creating a LabVIEW Sub VI for the INA219 sensor for detecting extremely low-level electrical quantities
...Show More Authors

An impressed current cathodic protection system (ICCP) requires measurements of extremely low-level quantities of its electrical characteristics. The current experimental work utilized the Adafruit INA219 sensor module for acquiring the values for voltage, current, and power of a default load, which consumes quite low power and simulates an ICCP system. The main problem is the adaptation of the INA219 sensor to the LabVIEW environment due to the absence of the library of this sensor. This work is devoted to the adaptation of the Adafruit INA219 sensor module in the LabVIEW environment through creating, developing, and successfully testing a Sub VI to be ready for employment in an ICCP system. The sensor output was monitored with an Arduino

... Show More
Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Mon Aug 26 2024
Journal Name
Jbpml
Studying The Changes in Motility and Morphology on Human sperm after exposure to low doses of x-rays
...Show More Authors

the energy that a radiation source emits as light (photons), electromagnetic waves, or particles is known as radiation. X-ray is one type of ionizing radiation that falls within the electromagnetic wave category of short wavelengths. Because of their short wavelength. X-ray is a type of ionizing radiation that is used in a constantly growing number of diagnostic procedures. X-ray diagnostic imaging has been employed in the medical field for more than a century(Hariyoto et al., 2020). Radiation has advantages for human health, but there is also a risk. the impacts of Radiation on Fertility it is an oligospermia, or a reduction in the number of sperm cells, which is already possible after radiation exposure of 0.15 mGy. It Leads to impede

... Show More
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Relationship between very low birth weight neonates and increased neonatal mortality for age 0 to 7 days
...Show More Authors

Background: Very low birth weight (VLBW) neonates constitute approximately 4–7 percent of all live births and their mortality is very high.
Objective: to find out if there is a relationship between Very Low Birth Weight Neonates and increased neonatal mortality for age 0 to 7 days.
Methods: A retrospective study of VLBW neonates admitted to NICU at Ibn Al- Baladi Pediatrics and Maternity hospital over one year (2012)were studied, The study period was from April till August 2013. Exclusion criteria were: (1) neonates weighing less than 700 g and with gestational age less than 24 weeks (abortion) (2) death in the delivery room (3) neonates weighing more than 1500 g. (4) Postnatal age more than 7 days. The outcome measure was in-hos

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 25 2025
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at the Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the first part of the work; that is the design calculations, simulation and construction. It will be followed by a second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70 m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow disturbances in the test section.

... Show More
View Publication