Rates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respectively, in absence and presence of bacteria. (iii) Increase of zinc consumption with flow rates (300-600l/hr) at different solution concentrations (1-3.5 %wt NaCl) while the time of exposure and temperature were fixed at 3h's and 30ºC respectively in absence and presence of bacteria. Generally the Zn consumption during cathodic protection ranges from (2.424- 26.741 g/m2) and (5.352-27.296g/m2) in absence and presence of bacteria respectively.
In this research, a selection of some mineral water was selected on the basis of being the most marketed by the owners of shops in Najaf province, with six types, where daily samples of this water were taken by 50 ml for two months from (1/11/2018 -1/1/2019). The following ions concentrations were measured (Br-, Cl-, F-, NO3-, SO42-, Na+, K+, Ca2+, Mg2+), pH and the electrical conductivity were measured and the results were compared with the allowable rates according to the international organizations. It was noted that they conform to international and Iraqi standards.
In this study, the stable isotop 18O and 2H has been used to investigate the interaction of surface water (SW), and groundwater (GW) in Al-Taji district/ Northern Baghdad for two seasons (March and August 2022). 16 Samples were collected from water resources in the Al-Taji district (Tigris channel, Tigris River, and groundwater), in each season water samples from 8 Tigris channel, 5 drilled wells, and 3 Tigris River were taken for the analysis of the isotopes 18O and 2H. The average analysis results of 18O and 2H in the Tigris channel, Tigris River, and groundwater were found to be -3.435‰ and -18.6094‰, -2.07167‰ and -17.81‰, -4.125‰ and -34.707‰ respectively. The results, generally, show a comparable range of isotope c
... Show MoreIn this part of programme , different bacterial isolates mainly Salmonella spp, Shigella spp and Escherichia coli were used for antagonism with Saccharomyces boulardii under different conditions . S.boulardii was grown under aerobic conditions and antagonized with young overnight nutrient broth cultures of test bacterial isolates and other kept in refrigerator for a week after full growth . Young cultures were more susceptible to antagonistic effect of yeast compared to old cultures and on isolates grown on solid medium for 24 hr. S.boulardii grown under aerobic and microaerobic conditions and antagonized with overnight broth cultures of test bacterial isolates , The results revealed that aerobic cultures of yeast had more inhibito
... Show MoreThree types of extracts ( aquatic, alcoholic, and oily ) were prepared from the fruits of coconuts, and a series of chemical tests were conducted in addition to the use of the FTIR equipment to determine the active locations in the prepared extracts. The results indicated the presence of active compounds (tannins, saponins, flavonoids, turbines and steroids) in the extracts prepared from the fruits of coconuts, also the antimicrobial capability of these extracts were tested on pathogenic bacteria isolated from wounds and burns infections cases. The results proved that the concentration 80 mg/ml of the aquatic extract is the minimum inhibitory concentration for the microbes: Proteus vulgaris and Pseudomonas fluorescence, while the
... Show MoreHuwaiza marsh is considered the largest marsh in the southern part of Iraq. It is located between 31° and 31.75° latitude and extends over the Iraqi-Iranian border; but the largest part lies in Iraq. It is located to the east of Tigris River in Messan and Basra governorates.
In this research, the variation of some water quality parameters at different locations of Huwaiza marsh were studied to find out its efficacy in the treatment of the contamination coming from the wastewater outfall of Kahlaa brokendown sewage treatment plant which lies on the Kahlaa River. This rive is the main feeder of Huwaiza marsh. Ten water quality sampling locations were chosen in this marsh. The water samples were taken during 2009 for three months; Janu