Preferred Language
Articles
/
ijcpe-453
Cathodic Protection of Copper Pipes Carrying Saline Water in the Presence of Aerobic Bacteria
...Show More Authors

Rates of zinc consumption during cathodic protection of a copper pipeline carrying saline water were measured by the loss in weight technique. The study of sacrificial anode cathodic protection of short copper tube using zinc strip extended axially in the pipe revealed that : (i) The increase of zinc consumption with time of exposure (1-3 h's) at different flow rates (turbulent flow) (300-600 l/hr) while the temperature , solution concentration and the pH were fixed at 20ºC, 3.5%wt NaCl, and pH=8 respectively in absence and presence of bacteria.(ii)Increase of zinc consumption with flow rates (300-600 l/hr) at different temperatures (10-40ºC) while solution concentration and time of exposure were fixed at 3.5 %wt NaCl and 3hr's respectively, in absence and presence of bacteria. (iii) Increase of zinc consumption with flow rates (300-600l/hr) at different solution concentrations (1-3.5 %wt NaCl) while the time of exposure and temperature were fixed at 3h's and 30ºC respectively in absence and presence of bacteria. Generally the Zn consumption during cathodic protection ranges from (2.424- 26.741 g/m2) and (5.352-27.296g/m2) in absence and presence of bacteria respectively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate
...Show More Authors

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Electrodepositing of Multi-Layer Ni-Ag Coated by Copper Nanoparticles for Solar Absorber
...Show More Authors

In this work, the effect of the addition of bright nickel plating and silver carried out by the electroplating method has been studied, on the coating of copper nanoparticles on the copper base metal via the process of thermal evaporation. The improvement of the solar absorber using CuNP in combination with the bright nickel and silver was obtained to be better than copper nanoparticles individually. A bright nickel enhanced the absorbed thermal stability. Also, other optical properties, absorptions, and emissivity slightly decreased from (93% to 87%), while the existence of silver had a slight impact on absorption of about (86.50%). On the other hand, thermal conductivity was evaluated using hot disk analyzer. The results showed a good

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Batch Sorption of Copper (II) Ions from Simulated Aqueous Solution by Banana Peel
...Show More Authors

This research presents the possibility of using banana peel (arising from agricultural production waste) as biosorbent for removal of copper from simulated aqueous solution. Batch sorption experiments were performed as a function of pH, sorbent dose, and contact time. The optimal pH value of Copper (II) removal by banana peel was 6. The amount of sorbed metal ions was calculated as 52.632 mg/g. Sorption kinetic data were tested using pseudo-first order, and pseudo-second order models. Kinetic studies showed that the sorption followed a pseudo second order reaction due to the high correlation coefficient and the agreement between the experimental and calculated values of qe. Thermodynamic parameters such as enthalpy change (ΔH

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Remediation of Groundwater Contaminated with Copper Ions by Waste Foundry Sand Permeable Barrier
...Show More Authors

The permeable reactive barrier (PRB) is one of the promising innovative in situ groundwater remediation technologies, in removing of copper from a contaminated shallow aquifer. The 1:1- mixture of waste foundry sand (WFS) and Kerbala’s sand (KS) was used for PRB. The WFS was represented the reactivity material while KS used to increase the permeability of PRB only. However, Fourier-transform infrared (FTIR) analysis proved that the carboxylic and alkyl halides groups are responsible for the sorption of copper onto WFS. Batch tests have been performed to characterize the equilibrium sorption properties of the (WFS+KS) mix in copper- containing aqueous
solutions. The sorption data for Cu+2 ions, obtained by batch experiments, have be

... Show More
View Publication Preview PDF
Crossref (15)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
EFFECT AMBIENT OXIDATION ON STRUCTURAL AND OPTICAL PROPERTIES OF COPPER OXIDE THIN FILMS
...Show More Authors

The structural, optical properties of copper oxide thin films ( CuO) thin films which have been prepared by thermal oxidation with exist air once and oxygen another have been studied. Structural analysis results of Cu thin films demonstrate that the single phase of Cu with high a crystalline structure with a preferred orientation (111). X-ray diffraction results confirm the formation of pure (CuO) phase in both methods of preparation. The optical constant are investigated and calculated such as absorption coefficient, refractive index, extinction coefficient and the dielectric constants for the wavelengths in the range (300-1100) nm.

Preview PDF
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Water Resources And Geosciences
Water Requirement and Water Productivity of Zea mays L. under Different Irrigation Systems in AlQadsia and Babylon Governorates
...Show More Authors

Two field experiments were conducted at two different texture sites. The first site of the fields of AlMed-hateya Agriculture Division / Babil Governorate. The second site of the fields of Al-Nouriah Research Station / Ministry of Agriculture, the factors of the study in the two sites included several factors. The first factor includes two irrigation systems: sprinkler irrigation and surface irrigation. The second factor is the method of cultivation which includes the method of cultivation with basin and furrowing. The third factor is the type of the cultivated crop which includes a local variety (Fajr 3) and a hybrid variety (Drakma). The actual water consumption for the sprinkler irrigation system reached (587.13 and 637.62) mm season-1 f

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 17 2008
Journal Name
Anbar Journal Of Agricultural Sciences 6 (2)‏
Influence of foliar sprays with Copper and Zinc on the resistance of citrus rootstocks to gumosis caused by Phytophthora citropthora. ‏
...Show More Authors

Publication Date
Wed Dec 01 2010
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
IDENTIFICATION OF PATHOGENIC FUNGI ASSOCIATED WITH WATER HYACINTH IN SELECTED REGIONS IN THE MIDDLE AND SOUTH OF IRAQ
...Show More Authors

To identify the fungi associated with water hyacinth (Eichhornia crassipes [Mart.] Solms), an aquatic weed, which presents in Tigris river from Baghdad south ward. Five regions from middle and south of Iraq (Al-Noumanya, Saeid Bin-Jubier, Al-Azizia, Al-Reyfay and Al-Hay) were selected for this study. Twelve fungal species were isolated. Alternaria alternata, Acremonium sp and Cladsporium herbarum, were the most frequently species (91.66 % ,50 % and 25 %) respectively. The fungi Alternaria alternata, Acremonium sp. and Phoma eupyrena were more aggressive to water hyacinth as (91.66%,83,33%, and 75%) in pathogenicity test.

View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Using of Index Biological Integrity of Phytoplankton (P-IBI) in the Assessment of Water Quality in Don River Section
...Show More Authors

       The multimetric Phytoplankton Index of Biological Integrity (P-IBI) was applied throughout Rostov on Don city (Russia) on 8 Locations in Don River from April – October 2019. The P-IBI is composed from seven metrics: Species Richness Index (SRI), Density of Phytoplankton and total biomass of phytoplankton and Relative Abundance (RA) for blue-green Algae, Green Algae, Bacillariophyceae and Euglenaphyceae Algae. The average P-IBI values fell within the range of (45.09-52.4). Therefore, water throughout the entire study area was characterized by the equally "poor" quality. Negative points of anthropogenic impact detected at the stations are: Above the city of Rostov-on-Don (1 km, higher duct Aksai) was 38.57 i

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Sep 30 2008
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Impact of Tigris River Pollution on the Performance of Water Treatment Plants Efficiencies in Baghdad City
...Show More Authors

The determination of river pollution impact on the performance of water treatment plants is achieved by two main objectives. The first is to study raw and treated water qualities and comparing them with standards and the second is to evaluate the treatment plants efficiency. The analyzed data were those water quality parameters in relation to physical, chemical and bacteriological characteristics for river water and produced water by seven water treatment plants located on Tigris River passing through Baghdad City.
The results of this study indicated that all raw water characteristic are within the surface water standards established by Iraqi and USA criteria except Bacterial Counts.
Tigris River water is of good quality to be trea

... Show More
View Publication Preview PDF