Preferred Language
Articles
/
ijcpe-446
Electrocoagulation of phenol for wastewater treatment
...Show More Authors

Electrocoagulation is an electrochemical process of treating polluted water where sacrificial anode corrodes to produce active coagulant (usually aluminum or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles). The present study investigates the removal of phenol from water by this method. A glass tank with 1 liter volume and two electrodes were used to perform the experiments. The electrode connected to a D.C. power supply. The effect of various factors on the removal of phenol (initial phenol concentration, electrode size, electrodes gab, current density, pH and treatment time) were studied. The results indicated that the removal efficiency decreased as initial phenol concentration increased, the highest removal obtained at pH in the range (6-8), the removal enhanced with increasing electrode size and decreasing the gab between the electrodes. The optimum current density obtained at 221 A/m2.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering
Application of Artificial Neural Network for Predicting Iron Concentration in the Location of Al-Wahda Water Treatment Plant in Baghdad City
...Show More Authors

Iron is one of the abundant elements on earth that is an essential element for humans and may be a troublesome element in water supplies.  In this research an AAN model was developed to predict iron concentrations in the location of Al- Wahda water treatment plant in Baghdad city by water quality assessment of iron concentrations at seven WTPs up stream Tigris River. SPSS software was used to build the ANN model. The input data were iron concentrations in the raw water for the period 2004-2011. The results indicated the best model predicted Iron concentrations at Al-Wahda WTP with a coefficient of determination 0.9142. The model used one hidden layer with two nodes and the testing error was 0.834. The ANN model coul

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 04 2008
Journal Name
Journal Of Baghdad College Of Dentistry
Twelve months clinical comparison between modified Widman flap with or without enamel matrix derivative for the treatment of infrabony defects
...Show More Authors

Publication Date
Tue Jun 15 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Assessment the Genotoxic Potential of Fluoxetine and Amitriptyline at Maximum Therapeutic Doses for Four-Week Treatment in Experimental Male Rats
...Show More Authors

Abstract

At any moment, the continuous usage of medications can accompanied by DNA damage and the accumulation of such damages can cause serious consequences. Antidepressants are long-term used drugs and the incidence of their genotoxic impacts cannot be excluded. Therefore, this work was designed to investigate the possible genotoxic effects of the commonly used antidepressants (fluoxetine and amitriptyline) in adult male rats.

Detection of DNA damage in individual cells was assessed by comet and micronucleus assays in three different cell populations i.e. liver, testis and bone marrow tissues of 24 swiss albino adult male rats. The animals were randomly allocated into three groups of 8 rats ea

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Proceeding Of The 1st International Conference On Advanced Research In Pure And Applied Science (icarpas2021): Third Annual Conference Of Al-muthanna University/college Of Science
Dimensional analysis of predicting the removal of chemical oxygen demand from domestic wastewater using moving bed biofilm reactor
...Show More Authors

Municipal wastewater sources are becoming increasingly important for reuse, for irrigation purposes, so they must be treated to meet environmentally friendly local or global standards. The aim of this study is to establish, calibrate, and validate a model for predicting chemical oxygen demand for the pilot plant of mobile biofilm reactors operating from municipal wastewater in Maaymyrh located in Hilla city Using the approach of dimensional analysis. The approach of Buckingham's theorem was used to derive a model of dimensional analysis design for the forecast of (COD) in the pilot plant. The effluent concentration (COD) It has been derived as a result of the influential concentration of (COD), dissolved oxygen (DO), volume of pilot plant

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Dec 24 2023
Journal Name
Journal Of The College Of Basic Education
Structural, Characterization, Biological and Studying the Enzyme Activity of some transition metal complexes with 4- )(2- hydroxy phenyl imino) methyl) -2, 6-dimethoxy phenol
...Show More Authors

A new Schiff bases ligand 4- ((2-hyolroxy phenylimino) methyl) -2, 6-dimethoxyphenol  derived from condensation of 2- amino phenol with 4-hydroxy -3, 5-dimethoxy benzaldehyde have been synthesized and characterized by  spectroscopy,  spectra, Mass spectrum and elemental microanalysis (C.H.N). Metal Complexes with ions have been also synthesized and characterized spectroscopic methods  spectroscopy, flame atomic absorption, molar conductivity measurements and magnetic susceptibility. These studies indicate that the moler ratio  for the complexes. The complexes  showed characteristics octahedral geometry with the (O,N) ligand coordinated in bidentate mode while with  showed square planer. The enzyme activity of the ligand and i

... Show More
View Publication
Crossref
Publication Date
Sat Oct 27 2018
Journal Name
Surface And Coatings Technology
Effect of surface treatment of zirconia-ceramic dental restorations
...Show More Authors

The zirconia ceramic restoration (ZCR) is used as substitutes for the metal-ceramic restoration. Clinical studies demonstrating of ZCRs showed a high fracture incidence of veneering layer than metal-ceramic restorations. This attributed to the low bond strength of zirconia to veneering ceramic as a result of lacking of glass content in its matrix. Surface treatment was proposed to improve the bonding strength between zirconia and veneering ceramic. Several studies revealed that some treatment such as airborne particle abrasion (APA) is responsible for generating chipping of veneering ceramic. The study aimed to develop a new zirconia coatings to increase bonding strength between zirconia substrate and veneering porcelain. Three groups of 15

... Show More
Preview PDF
Publication Date
Sun Oct 09 2022
Journal Name
المجلة الع ا رقية لعلوم التربة
ISOLATION AND IDENTIFICATION OF MULTI-DRUD RESISTANCE STAPHYLOCOCCUS AUREUS WHICH ISOLATES FROM IRRIGATION AND WASTEWATER IN BAGHDAD CITY*
...Show More Authors

A total number of 68 water samples was revealed 20 isolates being Staphylococcus aureus. Irrigation water isolates represented 25% of isolates while wastewater 75%. all isolates were identified by morphological, microscopial, biochemical tests and VITEK®2 Compact. Bacterial isolates were subjected to 16 antibiotics, all irrigation water and wastewater isolates were resistant to penicillin while they were fully sensitive to Ciprofloxcin. Irrigation water isolates showed relatively greater multi-drug resistance than wastewater, wherein irrigation water isolates showed 100% multi-drug resistance while wastewater isolates showed 73.3% multi-drug resistance, indicating the ability of S. aureus MDR to move from one site to another, which means t

... Show More
Publication Date
Mon Nov 15 2021
Journal Name
Aip Conference Proceedings
Oil skimming followed by coagulation/flocculation processes for oilfield produced water treatment and zero liquid discharge system application
...Show More Authors

The study focused on the treatment of real oilfield produced water from the East Baghdad field affiliated to the Midland Oil Company (Iraq) using an oil skimming process followed by a coagulation/flocculation process for zero liquid discharge system applications. Belt type oil skimmer was utilized for evaluating the process efficiency with various operating conditions such as temperature (17-40 °C) and time (0.5-2.5 hr.). Polyaluminum chloride (PAC) coagulant and polyacrylamide (PAM) flocculant was used to investigate the performance of the coagulation/flocculation process with PAC dosage (5-90 ppm) and pH (5-10) as operating conditions. In the skimming process, the oil content, COD, turbidity, and TSS decreased with an increase in tempera

... Show More
View Publication
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
...Show More Authors

This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression ana

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
...Show More Authors

This study aims to evaluate the performance of the sewage treatment plant in Al- Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regressio

... Show More