Preferred Language
Articles
/
ijcpe-418
Mixed convection in an Horizontal Rectangular Duct Including interior Circular Core with Time periodic Boundary Condition
...Show More Authors

Numerical Investigation was done for steady state laminar mixed convection and thermally and hydrodynamic fully developed flow through horizontal rectangular duct including circular core with two cases of time periodic boundary condition, first case  on the rectangular wall while keeping core wall constant and other on both the rectangular duct and core walls. The used governing equations are continuity momentum and energy equations. These equations are normalized and solved using the Vorticity-Stream function and the Body Fitted Coordinates (B.F.C.) methods. The Finite Difference approach with the Line Successive Over Relaxation (LSOR) method is used to obtain all the computational results the (B.F.C.) method is used to generate the grid of the problem. A computer program (Fortan 90) is built to calculate Nusselt Number (Nu) in steady state. The fluid Prandtl number is 0.7 Rayleigh Number  1<Ra<106, Reynolds number 1<Re<2000. For the range of parameters considered, results show that the time periodic boundary condition enhance heat transfer. It is also indicated in the results that heat transfer from the surface of the circle exceeds that of the rectangle duct. Comparisons with other research show good agreement.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Building Engineering
Discharge performance assessment of a vertical double-pipe latent heat storage unit equipped with circular Y-shaped fins
...Show More Authors

This paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol

... Show More
View Publication
Scopus (38)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Engineering, Technology &amp; Applied Science Research
A Numerical Study of Concrete Composite Circular Columns encased with GFRP I-Section using the Finite Element Method
...Show More Authors

This paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jan 30 2014
Journal Name
Al-kindy College Medical Journal
Managementt o f non traumatic A vascular Necrosis off Femoral Head at precollapse stage with Core Decompression and tibial Bone Grafting
...Show More Authors

 Avascular necrosis have always presented great challenges to orthopedic surgeons and patients, remain in many ways today the unsolved dilemma. Varieties of non-vascularized bone grafting techniques preceded by core decompression have been proposed with varying degrees of success. O bb j ee cc t i vv ee ss : The aim of this study is to review the the value of core decompression and non-vascularized tibial bone strip graft treatment for early stages of non-traumatic osteonecrosis stage II & III according to stein burg staging . M ee t hh oo dd ss : prospectively reviewed 26 patients (32 hips) with osteonecrosis of the femoral head between June 2006 and December 2013 at Imam Ali hospital in Sader city & Al-Wasity teaching hosp

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Low Loss in a Gas Filled Hollow Core Photonic crystal fiber
...Show More Authors

The work in this paper focuses on the experimental confirming of the losses in photonic crystal fibers (PCF) on the transmission of Q-switched Nd:YAG laser. First HC-PCF was evacuated to 0.1 mbar then the microstructure fiber (PCF) was filled with He gas & gas. Second the input power and output power of Q-switched Nd:YAG laser was measured in hollow core photonic bandgap fiber (HCPCF). In this work loss was calculated in the hollow core photonic crystal fiber (HCPCF) filled with air then N2, and He gases respectively. It has bean observed that the minimum loss obtained in case of filling (HC-PCF) with He gas and its equal to 15.070 dB/km at operating wavelength (1040-1090) nm.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Oct 03 2013
Journal Name
Heat Transfer-asian Research
CFD Simulation of Heat Transfer Augmentation in a Circular Tube Fitted with Alternative Axis Twisted Tape in Laminar Flow under a Constant Heat Flux
...Show More Authors

View Publication
Scopus (17)
Crossref (13)
Scopus Crossref
Publication Date
Tue Jun 03 2014
Journal Name
Heat Transfer - Asian Research
CFD Simulation of Heat Transfer Augmentation in a Circular Tube fitted with Alternative Axis Twisted Tape in Laminar Flow under the Constant Heat Flux
...Show More Authors

Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Ultrasound Guided Core Needle Biopsy in The Diagnosis of Suspicious Breast Lesions: Radiologist’s perspectives
...Show More Authors

Background: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.

Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.

Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V.  Ultrasound guided core needle biopsy was performed for each patient. Surgical pathol

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Oct 15 2024
Journal Name
Civileng
Structural Performance of a Hollow-Core Square Concrete Column Longitudinally Reinforced with GFRP Bars under Concentric Load
...Show More Authors

Concrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Synthesis, Characterization and Biological Activity of Mixed Ligand Metal Salts Complexes with Various Ligands
...Show More Authors

Metal (III) and (II) coordination compounds of o- phenylenediamine, oxalic acid dihydrate and 8-hydroxyquinoline were synthesized for mixed ligand complexes and characterized using FT-IR, UV-Vis and mass spectra, atomic absorption, elemental analysis, electric conductance and magnetic susceptibility measurements. In addition, thermal behavior (TGA) of the metal complexes (1-6) showed good agreement with the formula suggested from the analytical data. The stoichiometric reaction between the metal (III) and (II) ions with three various ligands in molar ratio at aqueous ethyl alchol for (1:1:1:1) (M: O-PDA: OA: 8-HQ) [where M = Cr+3, Mn+2, Co+2, Ni+2. Cu+2 and Zn+2; O-PDA = O-Phenylenediamine; OA = Oxalic acid and 8-HQ = 8-Hydroxyquinoline]. R

... Show More
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Synthesis, Characterization and Biological Activity of Mixed Ligand Metal Salts Complexes with Various Ligands
...Show More Authors

Metal (III) and (II) coordination compounds of o- phenylenediamine, oxalic acid dihydrate and 8-hydroxyquinoline were synthesized for mixed ligand complexes and characterized using FT-IR, UV-Vis and mass spectra, atomic absorption, elemental analysis, electric conductance and magnetic susceptibility measurements. In addition, thermal behavior (TGA) of the metal complexes (1-6) showed good agreement with the formula suggested from the analytical data. The stoichiometric reaction between the metal (III) and (II) ions with three various ligands in molar ratio at aqueous ethyl alchol for (1:1:1:1) (M: O-PDA: OA: 8-HQ) [where M = Cr+3, Mn+2, Co+2, Ni+2. Cu+2 and Zn+2; O-PDA = O-Phenylenediamine; OA = Oxalic acid and 8-HQ = 8-Hydroxyquinoline]. R

... Show More
View Publication
Scopus (27)
Crossref (6)
Scopus Crossref