Portable and stationary electrical generators became quite popular in Iraq soon after the shortage in national electrical
energy after 2003. Multi step risk assessment process is used in this study in the assessment of risks caused by
contamination of indoor air by lead particles emitted from domestic electrical generators. Two portable electrical
generators are tested under controlled indoor conditions (Radial LG (0.9 keV) fueled with benzene and oil and TigMax
(3 keV), fueled with benzene only). Lead particles in air were sampled by using portable dust sampler (Sniffer, L-30).
The atmospheric particulate sampling process is carried out in a flat located in the first floor of a three stories building
located in Baghdad city, Al-Zafarania region. The lead concentration in the digested filter papers is measured by using
atomic absorption spectrophotometer (Buck, USA). Dose-to-risk conversion factor is applied in this study to estimate the
potential cancer risk to Baghdad’s population related to continuous inhalation of airborne lead at the mean observed
concentrations. The results of toxicity analysis indicate that public exposure to airborne lead at the mean observed
concentration of 4.991 g/m3 can increase the risk of cancer at a rate of 12 extra cancer cases in a group of million
exposed individuals. Males are found to be at greater risk than females because of higher inhalation rates. Children are
found to be the most sensitive group due to low body weight (about 101 expected additional cancer cases in a group of
million exposed child).
The toxicological risks and lifetime cancer risks associated with exposure to disinfection by-products (DBPs) including Halloacetic acids (HAAs) and trihalomethanes (THMs) compounds by drinking water in several districts in Wassit Province were estimated. The seasonal variation of HAAs and THMs compounds in drinking water have indicated that the mean values for total HAAs (THAAs) and total THMs (TTHMs) ranged from 43.2 to 72.4 mg/l and from 40 to 115.5 mg/l, respectively. The World health organization index for additive toxicity approach was non-compliant with the WHO guideline value in summer and autumn seasons and this means that THMs concentration has adverse toxic health effects. The multi-pathway of lifetime hu
... Show MoreBackground: Environmental tobacco smoking is produced by active smokers burning the tip of a cigarette and breathed by nonsmokers and measured by cotinine level. It has the potential to raise the risk of periodontal disease. One of the most frequent chronic diseases in adults is periodontal disease. The lower maternal-fetal attachment has been found to predict smoking status in previous studies, but no research has examined whether maternal-fetal attachment predicts environmental tobacco smoking. This study assessed the effects of maternal environmental tobacco smoke exposure on periodontal health and mother-infant bonding concerning salivary cotinine levels. Materials and methods: This is a comparative cross-sectional study comparing en
... Show MoreOne of the functions of Al-Shanasheel was to cool the air, but they could not compete with the Evaporative coolers, As Al-Shanasheel were a sign of luxury and wealth in Arab societies and were only built in homes of wealthy families, they are more expensive than the evaporative coolers, depending on the level of the decoration and the sculpting used to create them aesthetically, where People replaced them with evaporative coolers for their low cost, and higher cooling efficiency. One of the reasons for the disappearance of Al-Shanasheel is the absence of the functional need for them, in exchange for the high cost of construction. The diminished role of Al-Shanasheel in the contemporary urban scene, although they are one of the most
... Show MoreThe effluent quality improvement being discharged from wastewater treatment plants is essential to maintain an environment and healthy water resources. This study was carried out to evaluate the possibility of intermittent slow sand filtration as a promising tertiary treatment method for the sequencing batch reactor (SBR) effluent. Laboratory scale slow sand filter (SSF) of 1.5 UC and 0.1 m/h filtration rate, was used to study the process performance. It was found that SSF IS very efficient in oxidizing organic matter with COD removal efficiency up to 95%, also it is capable of removing considerable amounts of phosphate with 76% and turbidity with 87% removal efficiencies. Slow sand filter efficiently reduced the mass of suspended
... Show MoreBiosorption is an effective method to remove toxic metals from wastewaters. In this study biosorption of lead and chromium ions from solution was studied using Citrobacter freundii and Citrobacter kosari isolated from industrial wastewater. The experimental results showed that optimum grwoth temperature for both bacteria is 30oC and the optimum pH is 7 &6 for C. freundii and C. kosari respectively. While the optimum incubation period to remove Pb and Cr for C. freundii and C. kosari is 4 days and 3days respectively. Also the biosorption of Pb and Cr in mixed culture of bacteria and mixed culture of Pb and Cr was investigated. Result indicate that uptake of Cr and Pb for C.freundii, C. kosari and in mixes culture of both bacteria is 58%, 53%
... Show MoreA field study was conducted on a sample of the public in Baghdad to study the audience's exposure to the television promotion of pharmaceutical products and their trends in order to determine the rate of exposure of the public to the television promotion of pharmaceutical products according to the theory of uses and rumors and to determine the public's attitudes towards television promotion of pharmaceutical products. A survey of (25) a questions was distributed to a sample of the audience of 150 people. The statistical program SPSS was used to unload the data and for the calculation of frequencies and percentages and correlation coefficients. The research reached several results, Most importantly, the television promotion is well receiv
... Show MoreThe efficiency of internal combustion engines (ICE) is usually about thirty percent of the total energy of the fuel. The residual energy is lost in the exhaust gas, the lubrication, and the cooling water in the radiators. Recently much of the researcher’s efforts have focused on taking advantage of wasted energy of the exhaust gas. Using a thermoelectric generator (TEG) is one of the promising ways. However, TEG depends entirely on the temperature difference, which may be offered by the exhaust muffler. An experimental test has been conducted to study the thermal performance of a different muffler internal design. The researchers resort to the use of lost energy in an ICE using TEG, which is one of the ways to take adv
... Show MoreThis study looks into the many methods that are used in the risk assessment procedure that is used in the construction industry nowadays. As a result of the slow adoption of novel assessment methods, professionals frequently resort to strategies that have previously been validated as being successful. When it comes to risk assessment, having a precise analytical tool that uses the cost of risk as a measurement and draws on the knowledge of professionals could potentially assist bridge the gap between theory and practice. This step will examine relevant literature, sort articles according to their published year, and identify domains and qualities. Consequently, the most significant findings have been presented in a manne
... Show MoreThe gamma dose rates and specific activity of 137Cs, 60Co and 40K in
samples of soil taken from places near the landfill radiation at Al-
Tuwaitha site were measured using a portable NaI(Tl) detector. The
results of gamma dose rates in samples were ranged from 52.6
nGy.h-1 to 131nGy.h-1. Then the specific activity of 137Cs, 60Co and
40K in soil were determined using high pure germanium (HPGe)
detector. The specific activities were varied from 1.9 to 115500 Bq.
kg-1 for 137Cs, from 6.37 to 616.5 Bq. kg-1 for 60Co, and from 3 to
839.5 Bq. kg-1 for 40K. The corresponding health risk for the annual
effective dose equivalent varied from 1.85×10-14 to 15.7mSv/y. The
results were compared with various internationa
Air pollution evaluation of the operational processes in the East Baghdad oil field was carried out. The analysis was carried out by ICP-MS technique. Total Suspended Particles (TSP) air load was higher than Iraqi Standards and world international allowable limits of World Health Organization. The mean concentrations of gases carbon monoxide, carbon dioxide, sulfur dioxide, in the air were within national and world standards, while the mean concentration of nitrogen dioxide was higher than standard limits. The air of the study area is considered a good quality for CO, CO2 and NO2 with no health effect, while it is hazardous for TSP that have serious risk for people with respiratory disease. The mean concentrations of Cd, Cr, Cu and
... Show More