Two different polyvinyl alcohol/polyvinyl chloride (PVA/PVC) hollow fiber composite nanofiltration membranes were prepared after PVC hollow fiber membranes were coated using dip-coating method with PVA aqueous solution, which was composed of PVA, fatty alcohol polyoxyethylene ether (AEO9), and water [PVA/AEO9/water (4:0.5:95.5) wt%]. Effect of two different PVC hollow fiber immersion times in coating solution were studied. Cross-section, internal and external surfaces of the PVC hollow fibers and PVA/PVC composite nanofiltration membranes structures were characterized by scanning electron microscopy (SEM), pure water permeation flux and solutes rejection. It was found that, the coating layer thickness on the outer surface of the 19 wt% PVC hollow fiber was thin and about (6μm), while the coating solution penetrates through the outer edge of the PVC hollow fiber and it looks like sponge-like structure with increase of the dip-coating time from 20 to 30 sec. Besides, the pure water permeation flux decreases and solutes rejection increases with an increase of the coating time from 20 to 30 sec for the two PVA/PVC composite nanofiltration membranes. Molecular weight cut-off (MWCO) of the PVA/PVC composite nanofiltration membranes were in the range of NF (i.e. 200-3000 Mw).
Tobacco products of all kinds are harmful to public health, so legislation has paid great attention to regulating the process of tobacco production and distribution, whether at the level of national or international legislation, in a way that achieves legal protection for these products, so the establishment of civil liability for tobacco companies as a result of harm to the smoker The positive and the negative provoked a jurisprudential dispute due to the specificity of the work of these companies, and the jurisprudence differed in the legal nature of tobacco companies ’liability between contractual and tort liability in a way that enables the injured smoker to obtain his right to compensation.
In this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(
In this paper, a computational method for solving optimal problem is presented, using indirect method (spectral methodtechnique) which is based on Boubaker polynomial. By this method the state and the adjoint variables are approximated by Boubaker polynomial with unknown coefficients, thus an optimal control problem is transformed to algebraic equations which can be solved easily, and then the numerical value of the performance index is obtained. Also the operational matrices of differentiation and integration have been deduced for the same polynomial to help solving the problems easier. A numerical example was given to show the applicability and efficiency of the method. Some characteristics of this polynomial which can be used for solvin
... Show More
Abstract
Friction stir welding is a relatively new joining process, which involves the joining of metals without fusion or filler materials. In this study, the effect of welding parameters on the mechanical properties of aluminum alloys AA2024-T351 joints produced by FSW was investigated.
Different ranges of welding parameters, as input factors, such as welding speed (6 - 34 mm/min) and rotational speed (725 - 1235 rpm) were used to obtain their influences on the main responses, in terms of elongation, tensile strength, and maximum bending force. Experimental measurements of main responses were taken and analyzed using DESIGN EXPERT 8 experimental design software which was used to develop t
... Show More500 samples of diarrhea stool were collected from different ages(less than 1year –upto30years) and for both genders from some patients in (Alwiya hospital for children, Al-kendi, central health public laboratory and some gavernarated labs) period(1/11/2009—1/10/2010). Kinds of bacteria and parasites agents were isolated and identified from patients with diarrhea. Nine species of gram negative bacteria from enterobacteriaceae were isolated, E. coli isolated are the higher ratio 4.8% of all, then Salmonella typhi4.6% while the lowest ratios is Citrobacterfreundii 0.4%, while the other identified species were be among the previous rotios. also Plesomonasshigelloides was isolated which concedride one of the bacterial local studies.many met
... Show MoreBackground: In the past, an association between Tuberculosis (TB) and Diabetes Mellitus (DM) was widely accepted, today the potential public health and clinical importance of this relationship seems to be largely ignored. The national clinical and policy guidance in the UK on the central of TB, for example, does not consider the relationship with DM.Objectives: To determine the risk of association between diabetes mellitus and pulmonary TB.Methods: A retrospective study conducted in Ibn Zuhr hospital for chest diseases from Jan 2008 – sep 2010 , included in the study 402 patients with TB divided into diabetic & non diabetic, 96 (23.8%) were diabetic while other 306 were TB not diabetic.Results: Risk of TB among DM patients were cle
... Show MoreKetoprofen has recently been proven to offer therapeutic potential in preventing cancers such as colorectal and lung tumors, as well as in treating neurological illnesses. The goal of this review is to show the methods that have been used for determining ketoprofen in pharmaceutical formulations. Precision product quality control is crucial to confirm the composition of the drugs in pharmaceutical use. Several analytical techniques, including chromatographic and spectroscopic methods, have been used for determining ketoprofen in different sample forms such as a tablet, capsule, ampoule, gel, and human plasma. The limit of detection of ketoprofen was 0.1 ng/ ml using liquid chromatography with tandem mass spectrometry, while it was 0
... Show More